Trigger Output1, Trigger Output2

Sets the TRIGGER OUT 1–2 jacks to function in sync with the power status of each zone or input switching.

Target Zone

Specifies the zone with which the TRIGGER OUT jack functions are synchronized.

Settings

Trigger Mode

Specifies the condition for the TRIGGER OUT jack to function.

Main

When “Trigger Mode” is set to “Power”, electronic signal transmission is synchronized with the power status of the main zone.

When “Trigger Mode” is set to “Source”, electronic signal transmission is synchronized with the input switching in the main zone.

Settings

Power (default)

The TRIGGER OUT jack functions in sync with the power status of the zone specified with “Target Zone”.

Zone2

When “Trigger Mode” is set to “Power”, electronic signal transmission is synchronized with the power status of Zone2.

When “Trigger Mode” is set to “Source”, electronic signal transmission is synchronized with the input switching in Zone2.

Source

The TRIGGER OUT jack functions in sync with the input switching in the zone specified with “Target Zone”.

An electronic signal is transmitted according to the setting made in “Source.”

All (default)

When “Trigger Mode” is set to “Power”, electronic signal transmission is synchronized with the power status of the main zone or Zone2. When “Trigger Mode” is set to “Source”, electronic signal transmission is synchronized with the input switching in the main zone or Zone2.

Manual

Source

Select this to manually switch the output level for electronic signal transmission with “Manual”.

DC OUT

Specifies the output level of the electronic signal transmitted with each input, switching when “Trigger Mode” is set to “Source”.

Choices

AV 1–7, V-AUX, AUDIO 1–4, PHONO, TUNER, (network sources), USB, MULTI CH

Settings

Configures the DC OUT jack setting.

Power Mode

Selects how to supply power to the Yamaha AV accessory connected to the DC OUT jack.

Settings

Low

Stops the electronic signal transmission when you switch to the input source specified in this option.

Continuous (default)

Supplies power through the DC OUT jack continuously regardless of

the power state (on/standby) of the unit.

 

High (default)

Manual

Transmits the electronic signal when you switch to the input source specified in this option.

Main Zone Power

Supplies power through the DC OUT jack only when the main zone is

turned on.

Sync.

(This setting may not work properly on some accessories.)

 

Switches the output level for electronic signal transmission manually when “Trigger Mode” is set to “Manual”. This setting can also be used to confirm proper function of the external device connected via the TRIGGER OUT jack.

Choices

Low

Stops the electronic signal transmission.

High (default)

Transmits the electronic signal.

 

 

CONFIGURATIONS Configuring various functions (Setup menu)