Optimizing the speaker setting for your listening room

If an error screen appears

Press Dk/ n/ l/ hto select “RETRY” or “EXIT” and then press DENTER.

The following display is an example where “E-9:USER CANCEL” appears in the OSD.

AUTO:ERROR

.E-9:USER CANCEL Don't operate

any function.

>RETRY EXIT

[[]/[[]:Select [ENTER]:Enter

Choices: RETRY, EXIT

Select “RETRY” to retry the “AUTO SETUP” procedure.

Select “EXIT” to exit from the “AUTO SETUP” procedure.

If “WARNING” appears

When this unit detects potential problems during the “AUTO SETUP” procedure, “WARNING” appears in the “AUTO:RESULT” display. Check the warning messages to correct your speaker settings.

Note

Warnings differ from errors in that warnings do not cancel the “AUTO SETUP” procedure.

1Make sure the pointer is pointing at “WARNING” and then press DENTER to

display the detailed information about the warning.

The number on the right of “WARNING” indicates the number of warning messages.

AUTO:RESULT

.WARNING(3)

RESULT

SP : 3/4/0.1

DIST: 14.0/17.0ft

LVL : -9.0/+6.5dB

>SET CANCEL

[]/[]:Up/Down

[ENTER]:Enter

2Press Dl/ hrepeatedly to toggle between the warning displays.

WARNING:W-1

<OUT OF PHASE>

Reverse Channel

FL --

CENTER

 

PL

PR

SL

SR

SBL

SBR

[[]/[[]:Select

[ENTER]:Return

y

For details about each warning message, see the “AUTO SETUP” section in “Troubleshooting” on page 101.

When the corresponding warning message is not applicable to a speaker, “– –” is displayed instead.

3Press DENTER to return to the top

“AUTO:RESULT” display.

32 En