Operation

EJU32670

Switches

ECJ00410

CAUTION:

Do not run the engine for more than 15 seconds when checking the switches on land without supplying water, otherwise the engine could overheat.

Check the start switch, the engine stop switch, and the engine shut-off switch for proper operation.

Push the start switch to start the engine. As soon as the engine starts running, push the engine stop switch to verify that the engine stops immediately. Restart the engine, and then pull the engine shut-off cord to remove the clip from the engine shut-off switch to verify that the engine stops immediately. (See pages 30 to 31 for information on proper operation of the start switch, the engine stop switch, and the engine shut-off switch.)

1Start switch

2Engine stop switch

3Engine shut-off switch

4Clip

5Engine shut-off cord

EJU32680

Cooling water pilot outlet

Check that water comes out from the cooling water pilot outlet while the engine is running

and the watercraft is in the water. (See page 31 for more information.)

EJU32710

Multifunction information center

Check the multifunction information center for proper operation. (See page 36 for information on proper operation of the multifunction information center.)

53