Maintenance and care
●For VX Deluxe/VX Cruiser: Shift cable (reverse gate end)
EJU34450
Checking the batteryCheck the level of the battery electrolyte and make sure that the negative
(+) battery leads are tightened securely.
EWJ00790
WARNING
Battery electrolyte is poisonous and dan- gerous, causing severe burns, etc. Electrolyte contains sulfuric acid. Avoid contact with skin, eyes, or clothing.
Antidotes
External: Flush with water.
Internal: Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg, or vegetable oil. Call a physician im- mediately.
Eyes: Flush with water for 15 minutes and get prompt medical attention.
Batteries produce explosive gases. Keep sparks, flames, cigarettes, etc., well away. If using or charging the battery in an enclosed space, make sure that it is well ven- tilated. Always shield your eyes when working near batteries.
KEEP OUT OF THE REACH OF CHILDREN.
ECJ00230
CAUTION:
●Be careful not to place the battery on its side.
●Be sure to remove the battery from the battery compartment when adding elec- trolyte or charging the battery.
To replenish the battery:
(1)Make sure that the electrolyte level is be- tween the maximum and minimum level marks.
1Maximum level mark
2Minimum level mark
(2)Refill the battery with distilled water if
necessary.
ECJ00240
CAUTION:
Normal tap water contains minerals that are harmful to a battery. Use only distilled water for replenishing the battery.
To recharge the battery:
ECJ00250
CAUTION:
Do not attempt to charge a battery hastily. Battery life could be shortened.
It is recommended to have a Yamaha dealer charge the battery. If you charge the battery yourself, carefully read the battery charger instructions before charging and follow the points below.
79