York 2000 warranty COOLING CAPACITIES - 3 TON BCH036

Models: 2000

1 24
Download 24 pages 58.42 Kb
Page 4
Image 4
COOLING CAPACITIES - 3 TON (BCH036)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-21564-003-A-1005

COOLING CAPACITIES - 3 TON (BCH036)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

85 °F

 

 

 

 

 

 

 

 

 

 

 

 

95 °F

 

 

 

 

 

 

 

Coil

 

 

 

 

Sensible Capacity

1

, MBH

 

 

 

 

 

 

 

 

1

, MBH

 

 

 

 

 

 

Total

Power

 

 

 

Total

Power

 

 

Sensible Capacity

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

51

3.4

37

32

28

24

 

19

-

 

-

47

3.7

 

34

29

25

22

17

-

-

 

1750

 

67

46

3.4

40

40

36

31

 

26

21

 

16

44

3.7

 

38

38

34

29

24

20

15

 

 

62

42

3.3

42

42

41

39

 

34

29

 

24

38

3.6

 

38

38

37

35

30

26

21

 

 

 

 

 

 

 

 

 

 

 

57

42

3.3

42

42

42

40

 

35

30

 

25

37

3.6

 

37

37

37

35

30

26

22

 

 

 

 

72

49

3.4

35

30

26

22

 

18

-

 

-

46

3.7

 

32

28

24

20

16

-

-

 

1500

 

67

45

3.4

39

37

33

29

 

24

20

 

15

42

3.7

 

36

34

30

27

22

18

14

 

 

62

41

3.3

41

41

40

37

 

32

28

 

24

37

3.6

 

37

37

36

33

28

25

21

 

 

 

 

 

 

 

 

 

 

 

57

41

3.3

41

41

41

38

 

34

29

 

25

36

3.6

 

36

36

36

33

29

25

21

 

 

 

 

72

48

3.4

33

29

24

20

 

16

-

 

-

45

3.7

 

30

27

22

18

15

-

-

 

1400

 

67

44

3.3

39

36

32

28

 

23

20

 

15

41

3.7

 

36

33

29

26

21

18

13

 

 

62

40

3.3

40

39

38

34

 

30

26

 

22

36

3.6

 

36

35

34

30

27

23

19

 

 

 

 

 

 

 

 

 

 

 

57

40

3.3

40

40

39

35

 

31

27

 

23

36

3.5

 

36

36

35

31

27

24

20

 

 

 

 

72

47

3.4

31

27

24

20

 

16

-

 

-

44

3.7

 

29

25

22

18

14

-

-

 

 

1200

 

67

41

3.3

36

32

29

25

 

22

18

 

14

39

3.6

 

34

30

27

23

20

17

13

 

 

 

62

38

3.3

38

37

36

32

 

29

25

 

21

35

3.6

 

35

34

33

29

26

23

19

 

 

 

 

 

 

 

 

 

 

 

57

37

3.3

37

37

36

33

 

30

26

 

22

35

3.5

 

35

35

34

31

28

24

20

 

 

 

 

72

45

3.3

28

25

22

19

 

16

-

 

-

42

3.6

 

26

23

20

17

14

-

-

 

1050

 

67

41

3.3

34

30

27

24

 

20

17

 

14

38

3.6

 

31

27

25

22

18

15

12

 

 

62

36

3.3

36

35

33

30

 

27

24

 

21

34

3.5

 

34

33

31

28

25

22

19

 

 

 

 

 

 

 

 

 

 

 

57

36

3.3

36

36

34

31

 

28

25

 

22

33

3.5

 

33

33

31

28

25

22

20

 

 

 

 

72

45

3.3

26

24

20

17

 

15

-

 

-

40

3.6

 

23

21

17

15

13

-

-

 

900

 

67

39

3.3

31

28

25

22

 

19

17

 

14

35

3.6

 

27

25

22

19

17

15

12

 

 

62

35

3.2

35

34

32

29

 

25

23

 

20

32

3.5

 

32

30

28

25

22

20

17

 

 

 

 

 

 

 

 

 

 

 

57

35

3.2

35

35

32

30

 

26

24

 

21

31

3.5

 

31

31

28

26

23

21

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

105 °F

 

 

 

 

 

 

 

 

 

 

 

 

115 °F

 

 

 

 

 

 

 

Coil

 

 

 

 

Sensible Capacity

1

, MBH

 

 

 

 

 

 

 

 

1

, MBH

 

 

 

 

 

 

Total

Power

 

 

 

Total

Power

 

 

Sensible Capacity

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

44

4.0

31

27

24

20

 

16

-

 

-

42

4.2

 

30

26

23

19

15

-

-

 

1750

 

67

40

4.0

34

34

31

26

 

22

18

 

13

36

4.1

 

31

31

28

24

20

16

12

 

 

62

35

3.9

35

35

34

32

 

28

24

 

20

34

4.1

 

34

34

33

31

27

23

19

 

 

 

 

 

 

 

 

 

 

 

57

35

3.9

35

35

35

33

 

29

25

 

20

33

4.1

 

33

33

33

31

27

23

19

 

 

 

 

72

43

4.0

30

26

22

19

 

15

-

 

-

41

4.2

 

29

25

21

18

15

-

-

 

1500

 

67

38

4.0

32

31

27

24

 

20

16

 

12

35

4.1

 

30

28

25

22

18

15

11

 

 

62

34

3.9

34

34

33

30

 

26

23

 

19

33

4.1

 

33

33

32

29

25

22

19

 

 

 

 

 

 

 

 

 

 

 

57

34

3.9

34

34

34

31

 

28

24

 

20

32

4.1

 

32

32

32

29

26

22

19

 

 

 

 

72

42

4.0

28

25

21

17

 

14

-

 

-

39

4.2

 

26

23

19

16

13

-

-

 

1400

 

67

37

4.0

32

30

26

23

 

19

16

 

12

34

4.1

 

30

27

24

21

17

15

11

 

 

62

33

3.9

33

32

31

28

 

24

21

 

18

32

4.1

 

32

31

30

27

24

20

17

 

 

 

 

 

 

 

 

 

 

 

57

32

3.8

32

32

31

28

 

24

21

 

18

32

4.0

 

32

32

31

28

24

21

18

 

 

 

 

72

41

4.0

27

23

20

17

 

13

-

 

-

37

4.2

 

24

21

18

15

12

-

-

 

1200

 

67

35

3.9

30

27

24

21

 

18

15

 

11

32

4.1

 

28

24

22

19

17

14

10

 

 

62

32

3.9

32

31

30

26

 

24

21

 

17

30

4.1

 

30

29

28

25

22

19

16

 

 

 

 

 

 

 

 

 

 

 

57

31

3.8

31

31

31

27

 

25

21

 

18

29

4.0

 

29

29

29

25

23

20

17

 

 

 

 

72

40

3.9

24

22

19

16

 

14

-

 

-

35

4.1

 

21

19

17

14

12

-

-

 

1050

 

67

34

3.9

28

24

22

19

 

16

14

 

11

31

4.0

 

25

22

20

18

15

12

10

 

 

62

30

3.8

30

29

27

25

 

22

20

 

17

29

4.0

 

29

28

26

24

21

19

16

 

 

 

 

 

 

 

 

 

 

 

57

30

3.8

30

30

28

25

 

23

20

 

18

28

4.0

 

28

28

26

24

21

19

17

 

 

 

 

72

38

3.9

21

20

16

14

 

12

-

 

-

34

4.1

 

19

18

15

12

11

-

-

 

900

 

67

32

3.9

25

22

20

18

 

15

13

 

11

29

4.0

 

23

20

18

16

14

12

10

 

 

62

29

3.8

29

27

25

23

 

20

18

 

16

27

4.0

 

27

25

24

21

18

17

15

 

 

 

 

 

 

 

 

 

 

 

57

29

3.8

29

29

26

24

 

21

19

 

17

26

4.0

 

26

26

23

22

19

17

15

 

1These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

4

Unitary Products Group

Page 4
Image 4
York 2000 warranty COOLING CAPACITIES - 3 TON BCH036