036-21564-003-A-1005

HEATING CAPACITIES

 

 

 

 

 

BCH036

 

 

 

 

 

CFM

RET. AIR

CAP

 

 

OUTDOOR AIR TEMPERATURE, °F (72% RH)

 

 

°F

& KW

-10

0

10

20

30

40

50

60

 

 

55

MBH

13.1

16.4

23.5

29.1

30.2

41.7

47.0

48.2

 

KW

2.9

3.0

3.2

3.3

3.5

3.7

3.8

3.9

 

 

1750

70

MBH

11.9

15.0

21.5

26.7

27.7

38.2

43.1

44.1

KW

3.0

3.1

3.4

3.4

3.6

3.8

3.9

4.1

 

 

 

80

MBH

10.9

13.6

19.6

24.3

25.2

34.8

39.3

40.2

 

KW

3.1

3.2

3.4

3.5

3.8

3.9

4.1

4.2

 

 

 

55

MBH

12.4

15.5

22.5

27.7

28.7

39.6

44.7

45.8

 

KW

2.7

2.9

3.0

3.1

3.3

3.5

3.6

3.7

 

 

1400

70

MBH

11.4

14.1

20.3

25.2

26.1

36.1

40.7

41.6

KW

2.9

3.0

3.2

3.3

3.5

3.7

3.8

3.9

 

 

 

80

MBH

10.4

13.1

18.0

23.2

24.2

33.3

37.6

38.5

 

KW

3.0

3.1

3.2

3.4

3.6

3.8

3.9

4.0

 

 

 

55

MBH

11.8

14.8

21.3

26.5

27.5

37.8

42.7

43.7

 

KW

2.7

2.8

3.0

3.1

3.3

3.4

3.5

3.6

 

 

1200

70

MBH

10.8

13.5

19.4

24.0

24.9

34.4

38.8

39.7

KW

2.9

3.0

3.1

3.3

3.4

3.6

3.7

3.8

 

 

 

80

MBH

9.9

12.4

17.8

22.0

22.9

31.5

35.6

36.5

 

KW

2.9

3.1

3.2

3.4

3.5

3.7

3.8

3.9

 

 

 

55

MBH

11.2

14.1

20.3

25.2

26.1

35.9

40.6

41.6

 

KW

2.6

2.7

2.9

3.0

3.3

3.3

3.5

3.5

 

 

1050

70

MBH

10.2

12.8

18.5

22.8

23.6

32.7

36.9

37.8

KW

2.8

2.9

3.0

3.2

3.3

3.5

3.6

3.7

 

 

 

80

MBH

9.3

11.7

16.7

20.7

21.5

29.8

33.6

34.4

 

KW

2.8

3.0

3.1

3.3

3.4

3.6

3.7

3.8

 

 

 

 

 

 

 

BCH048

 

 

 

 

 

 

55

MBH

12.3

17.3

22.5

28.2

36.3

44.5

53.8

61.6

 

KW

3.4

3.5

3.6

3.6

3.8

4.0

4.6

5.2

 

 

2000

70

MBH

11.8

16.6

21.6

27.1

34.9

42.8

51.7

59.2

KW

3.5

3.6

3.8

3.8

4.0

4.2

4.8

5.4

 

 

 

80

MBH

10.9

15.3

19.9

24.9

32.1

39.4

47.6

54.5

 

KW

3.6

3.7

4.0

4.0

4.1

4.4

5.0

5.7

 

 

 

55

MBH

12.1

17.0

22.0

27.7

34.5

42.3

51.2

58.6

 

KW

3.3

3.4

3.5

3.6

3.6

3.8

4.4

5.0

 

 

1600

70

MBH

11.6

16.3

21.2

26.6

33.2

40.7

49.2

56.3

KW

3.4

3.5

3.6

3.7

3.8

4.0

4.6

5.2

 

 

 

80

MBH

10.7

15.0

19.5

24.5

30.5

37.4

45.3

51.8

 

KW

3.5

3.6

3.8

3.9

4.0

4.2

4.8

5.4

 

 

 

55

MBH

10.9

15.3

19.9

24.9

31.7

38.9

47.0

53.8

 

KW

3.1

3.2

3.3

3.4

3.5

3.7

4.2

4.8

 

 

1200

70

MBH

10.5

14.7

19.1

24.0

30.5

37.4

45.2

51.7

KW

3.2

3.3

3.4

3.5

3.6

3.8

4.4

5.0

 

 

 

80

MBH

9.6

13.5

17.6

22.0

28.1

34.4

41.6

47.6

 

KW

3.3

3.4

3.5

3.6

3.8

4.0

4.6

5.2

 

 

 

 

 

 

 

BCH060

 

 

 

 

 

 

55

MBH

18.2

24.7

31.1

38.4

45.6

55.4

64.7

75.6

 

KW

5.0

5.1

5.2

5.3

5.3

5.6

5.9

6.5

 

 

2500

70

MBH

17.5

23.7

29.9

37.0

43.9

53.3

62.2

72.7

KW

5.2

5.3

5.4

5.5

5.6

5.9

6.2

6.8

 

 

 

80

MBH

16.1

21.8

27.5

34.0

40.4

49.0

57.2

66.9

 

KW

5.4

5.6

5.7

5.8

5.9

6.0

6.5

7.2

 

 

 

55

MBH

18.0

24.4

30.8

38.1

45.0

54.7

63.9

74.7

 

KW

4.7

4.8

4.9

5.0

5.3

5.5

5.8

6.4

 

 

2000

70

MBH

17.3

23.5

29.6

36.6

43.3

52.6

61.4

71.8

KW

4.9

5.0

5.1

5.2

5.5

5.8

6.1

6.7

 

 

 

80

MBH

15.9

21.6

27.2

33.7

39.8

48.4

56.5

66.1

 

KW

5.1

5.3

5.4

5.5

5.8

6.1

6.4

7.0

 

 

 

55

MBH

16.2

22.0

27.8

34.3

41.4

50.2

58.7

68.6

 

KW

4.5

4.6

4.7

4.8

5.0

5.3

5.5

6.1

 

 

1500

70

MBH

15.6

21.2

26.7

33.0

39.8

48.3

56.4

66.0

KW

4.7

4.8

4.9

5.0

5.2

5.5

5.8

6.4

 

 

 

80

MBH

14.4

19.5

24.6

30.4

36.6

44.5

51.9

60.7

 

KW

4.9

5.0

5.1

5.2

5.5

5.8

6.1

6.7

 

 

Unitary Products Group

7

Page 7
Image 7
York 2000 warranty Heating Capacities, CFM RET. AIR CAP Outdoor AIR TEMPERATURE, F 72% RH MBH