York 2000 warranty COOLING CAPACITIES - 5 TON BCH060

Models: 2000

1 24
Download 24 pages 58.42 Kb
Page 6
Image 6
COOLING CAPACITIES - 5 TON (BCH060)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-21564-003-A-1005

COOLING CAPACITIES - 5 TON (BCH060)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

85 °F

 

 

 

 

 

 

 

 

 

 

 

95 °F

 

 

 

 

 

 

 

 

Coil

 

 

 

 

 

 

 

1

, MBH

 

 

 

 

 

Sensible Capacity

1

, MBH

 

 

 

 

 

 

Total

Power

 

Sensible Capacity

 

Total

Power

 

 

 

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

68

5.7

51

44

38

31

 

-

 

-

 

-

67

6.0

 

51

45

38

31

-

 

-

-

 

2500

 

67

65

5.6

58

56

50

43

 

37

30

 

-

64

5.9

 

56

56

50

43

37

30

-

 

 

62

61

5.6

61

61

59

53

 

46

39

 

33

59

5.9

 

59

59

57

50

44

38

31

 

 

 

 

 

 

 

 

 

 

 

57

60

5.5

60

60

59

53

 

47

40

 

33

58

5.8

 

58

58

57

51

44

39

32

 

 

 

 

72

67

5.6

48

42

36

30

 

-

 

-

 

-

66

5.9

 

48

42

36

30

-

 

-

-

 

2250

 

67

64

5.6

57

54

48

42

 

36

30

 

-

63

5.9

 

55

54

48

42

35

29

-

 

 

62

60

5.5

60

60

57

51

 

45

39

 

33

57

5.8

 

57

57

55

50

44

38

32

 

 

 

 

 

 

 

 

 

 

 

57

59

5.5

59

59

58

52

 

46

40

 

34

57

5.8

 

57

57

56

50

45

39

33

 

 

 

 

72

66

5.6

45

40

34

29

 

-

 

-

 

-

65

5.9

 

45

40

34

29

-

 

-

-

 

 

2000

 

67

63

5.5

56

51

45

40

 

35

29

 

-

61

5.9

 

55

51

45

40

34

29

-

 

 

 

62

59

5.4

59

59

55

50

 

44

39

 

33

56

5.8

 

56

56

54

49

44

38

33

 

 

 

 

 

 

 

 

 

 

 

57

58

5.4

58

58

57

52

 

46

41

 

36

56

5.7

 

56

56

55

50

44

39

34

 

 

 

 

72

64

5.5

42

37

32

27

 

-

 

-

 

-

62

5.9

 

43

38

33

28

-

 

-

-

 

1750

 

67

61

5.5

52

47

42

37

 

33

28

 

-

59

5.8

 

53

48

44

39

34

29

-

 

 

62

57

5.4

57

56

51

46

 

41

37

 

32

54

5.7

 

54

54

52

48

43

38

33

 

 

 

 

 

 

 

 

 

 

 

57

57

5.4

57

57

53

48

 

44

39

 

34

54

5.7

 

54

54

53

49

43

39

34

 

 

 

 

72

62

5.5

38

34

30

25

 

-

 

-

 

-

60

5.8

 

41

36

32

28

-

 

-

-

 

1500

 

67

59

5.5

48

43

39

35

 

31

26

 

-

57

5.8

 

51

46

42

38

34

29

-

 

 

62

55

5.4

55

52

47

43

 

39

35

 

30

52

5.7

 

52

52

50

46

42

38

34

 

 

 

 

 

 

 

 

 

 

 

57

55

5.3

55

54

49

45

 

41

37

 

32

52

5.6

 

52

52

51

47

42

39

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

105 °F

 

 

 

 

 

 

 

 

 

 

 

115 °F

 

 

 

 

 

 

 

 

Coil

 

 

 

 

 

 

 

1

, MBH

 

 

 

 

 

Sensible Capacity

1

, MBH

 

 

 

 

 

 

Total

Power

 

Sensible Capacity

 

Total

Power

 

 

 

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

64

6.0

51

44

38

31

 

-

 

-

 

-

60

6.9

 

50

43

37

30

-

 

-

-

 

2500

 

67

59

5.9

51

51

49

42

 

36

29

 

-

54

6.6

 

54

53

47

41

34

27

-

 

 

62

54

5.9

54

54

51

46

 

40

33

 

26

49

6.5

 

49

49

48

42

35

28

22

 

 

 

 

 

 

 

 

 

 

 

57

54

5.8

54

54

52

46

 

41

33

 

26

49

6.5

 

49

49

49

43

35

28

23

 

 

 

 

72

63

5.9

48

42

36

30

 

-

 

-

 

-

60

6.8

 

47

41

35

29

-

 

-

-

 

2250

 

67

58

5.9

51

51

46

40

 

34

28

 

-

54

6.6

 

47

47

45

39

32

26

-

 

 

62

53

5.8

53

53

52

46

 

40

34

 

28

49

6.5

 

49

49

47

42

36

30

24

 

 

 

 

 

 

 

 

 

 

 

57

53

5.8

53

53

52

46

 

41

35

 

27

49

6.4

 

49

49

48

43

37

31

25

 

 

 

 

72

62

5.9

45

39

34

28

 

-

 

-

 

-

59

6.8

 

44

38

33

27

-

 

-

-

 

2000

 

67

57

5.9

51

49

44

38

 

33

27

 

-

53

6.5

 

45

45

42

36

31

26

-

 

 

62

52

5.8

52

52

51

46

 

40

35

 

30

48

6.4

 

48

48

46

42

36

31

25

 

 

 

 

 

 

 

 

 

 

 

57

52

5.7

52

52

51

46

 

40

36

 

31

47

6.4

 

47

47

46

43

36

32

25

 

 

 

 

72

60

5.9

41

37

32

27

 

-

 

-

 

-

56

6.7

 

40

35

30

25

-

 

-

-

 

1750

 

67

55

5.8

48

46

41

36

 

31

26

 

-

51

6.5

 

43

43

38

33

29

24

-

 

 

62

50

5.7

50

50

48

43

 

39

34

 

29

46

6.4

 

46

46

43

38

33

28

24

 

 

 

 

 

 

 

 

 

 

 

57

50

5.7

50

50

48

43

 

39

34

 

30

45

6.3

 

45

45

43

38

33

28

25

 

 

 

 

72

57

5.8

38

34

30

25

 

-

 

-

 

-

53

6.6

 

36

31

27

23

-

 

-

-

 

1500

 

67

53

5.8

47

43

38

34

 

30

26

 

-

48

6.4

 

41

39

35

30

26

22

-

 

 

62

48

5.7

48

48

45

41

 

37

32

 

28

44

6.3

 

44

44

39

35

30

26

22

 

 

 

 

 

 

 

 

 

 

 

57

48

5.6

48

48

45

41

 

38

32

 

28

43

6.2

 

43

43

40

36

30

26

23

 

1These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

6

Unitary Products Group

Page 6
Image 6
York 2000 warranty COOLING CAPACITIES - 5 TON BCH060