York 292443-XTG-D-0508 DNA042 COOLING CAPACITIES - 3-1/2TON, Johnson Controls Unitary Products

Models: 292443-XTG-D-0508

1 28
Download 28 pages 58.49 Kb
Page 10
Image 10

292443-XTG-D-0508

TABLE 5: DNA042 COOLING CAPACITIES - 3-1/2 TON

TEMPERATURE

 

 

 

 

 

 

 

 

 

AIR ON EVAPORATOR COIL

 

 

 

 

 

 

 

 

 

1,050 CFM

 

 

1,225 CFM

 

 

 

1,400 CFM

 

 

1,575 CFM

 

 

1,750 CFM

 

OF AIR ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB °F

 

 

WB °F

 

 

 

WB °F

 

 

WB °F

 

 

WB °F

 

CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

62

57

72

67

62

57

 

72

67

62

57

72

67

62

57

72

67

62

57

 

 

NET CAP.

 

44.5

40.8

37.6

36.5

46.0

42.2

38.8

37.7

 

47.5

43.6

40.1

38.9

48.9

44.9

41.3

40.1

50.3

46.2

42.5

41.2

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.01

4.00

3.85

3.85

4.16

4.15

4.00

4.00

 

4.31

4.31

4.15

4.15

4.36

4.35

4.19

4.19

4.40

4.39

4.23

4.23

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

23.6

29.7

35.1

35.9

27.6

34.2

37.6

37.4

 

31.6

38.6

40.1

38.9

31.0

38.5

41.3

40.1

30.5

38.4

42.5

41.2

85 °F

MBH

 

DryEntering °FBulb

 

83

22.5

28.6

34.0

34.8

25.3

31.9

37.0

36.8

 

28.1

35.1

40.1

38.9

28.6

36.1

41.3

40.1

29.1

37.1

42.5

41.2

 

 

1

 

 

 

80

21.4

27.5

32.9

33.7

23.0

29.6

35.4

36.2

 

24.6

31.7

37.9

38.8

26.2

33.7

40.2

40.0

27.8

35.7

42.5

41.2

 

 

 

 

 

 

77

20.3

26.4

31.8

32.6

20.7

27.3

33.1

34.0

 

21.2

28.2

34.4

35.3

23.8

31.3

37.8

37.6

26.4

34.3

41.1

39.9

 

 

 

 

 

 

74

19.2

25.4

30.7

31.5

18.5

25.1

30.8

31.7

 

17.7

24.7

30.9

31.8

21.4

28.9

35.3

35.2

25.0

33.0

39.7

38.5

 

 

 

 

 

 

71

-

24.3

29.7

30.4

-

22.8

28.6

29.4

 

-

21.3

27.5

28.4

-

26.4

32.9

32.8

-

31.6

38.4

37.2

 

 

 

 

 

 

68

-

23.2

28.6

29.4

-

20.5

26.3

27.1

 

-

17.8

24.0

24.9

-

24.0

30.5

30.3

-

30.2

37.0

35.8

 

 

NET

CAP.

 

 

41.5

38.0

34.6

35.0

43.2

39.6

36.0

36.4

 

44.9

41.1

37.3

37.8

46.1

42.2

38.3

38.8

47.2

43.2

39.3

39.8

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.24

4.22

4.07

4.10

4.40

4.38

4.22

4.25

 

4.56

4.54

4.38

4.40

4.62

4.60

4.43

4.46

4.68

4.66

4.49

4.52

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

26.5

32.7

34.6

35.0

29.0

35.7

36.0

36.4

 

31.4

38.7

37.3

37.8

30.3

38.0

38.3

38.8

29.2

37.3

39.3

39.8

95 °F

MBH

 

DryEntering °FBulb

 

83

23.4

29.6

33.8

34.1

25.5

32.3

35.6

36.0

 

27.6

34.9

37.3

37.8

27.7

35.4

38.3

38.8

27.8

35.9

39.3

39.8

 

 

1

 

 

 

80

20.3

26.5

30.7

31.0

22.1

28.8

33.4

33.8

 

23.9

31.2

36.1

36.5

25.2

32.9

37.7

38.2

26.5

34.6

39.3

39.8

 

 

 

 

 

 

77

17.1

23.3

27.6

27.9

18.6

25.4

30.0

30.3

 

20.1

27.4

32.4

32.8

22.6

30.3

35.2

35.6

25.1

33.2

37.9

38.4

 

 

 

 

 

 

74

14.0

20.2

24.4

24.7

15.2

21.9

26.5

26.9

 

16.3

23.7

28.6

29.0

20.0

27.7

32.6

33.0

23.7

31.8

36.6

37.1

 

 

 

 

 

 

71

-

17.1

21.3

21.6

-

18.5

23.1

23.4

 

-

19.9

24.9

25.2

-

25.2

30.0

30.5

-

30.4

35.2

35.7

 

 

 

 

 

 

68

-

13.9

18.1

18.5

-

15.0

19.6

20.0

 

-

16.1

21.1

21.5

-

22.6

27.5

27.9

-

29.1

33.8

34.3

 

 

NET

CAP.

 

 

38.7

34.7

32.2

33.0

40.3

36.1

33.5

34.3

 

41.8

37.5

34.8

35.6

42.8

38.4

35.6

36.5

43.8

39.2

36.5

37.3

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.51

4.44

4.34

4.34

4.67

4.59

4.49

4.49

 

4.82

4.74

4.63

4.64

4.90

4.82

4.71

4.71

4.98

4.90

4.78

4.79

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

23.6

29.4

31.7

31.8

25.7

32.0

33.3

33.7

 

27.8

34.6

34.8

35.6

28.0

35.1

35.6

36.4

28.1

35.7

36.5

37.3

105 °F

MBH

 

DryEntering °FBulb

 

83

21.5

27.3

30.9

30.9

23.4

29.7

32.9

32.9

 

25.3

32.1

34.8

35.0

26.1

33.2

35.6

36.2

26.8

34.4

36.5

37.3

 

 

1

 

 

 

80

19.5

25.3

28.9

28.8

21.2

27.5

31.4

31.3

 

22.9

29.7

33.8

33.8

24.2

31.3

35.2

35.5

25.5

33.0

36.5

37.3

 

 

 

 

 

 

77

17.5

23.3

26.8

26.8

18.9

25.2

29.1

29.1

 

20.4

27.2

31.4

31.4

22.3

29.5

33.3

33.7

24.1

31.7

35.1

36.0

 

 

 

 

 

 

74

15.4

21.2

24.8

24.7

16.7

23.0

26.9

26.8

 

18.0

24.8

28.9

28.9

20.4

27.6

31.4

31.8

22.8

30.4

33.8

34.6

 

 

 

 

 

 

71

-

19.2

22.7

22.7

-

20.7

24.6

24.6

 

-

22.3

26.5

26.5

-

25.7

29.5

29.9

-

29.0

32.5

33.3

 

 

 

 

 

 

68

-

17.1

20.7

20.7

-

18.5

22.4

22.3

 

-

19.9

24.0

24.0

-

23.8

27.6

28.0

-

27.7

31.1

32.0

 

 

NET

CAP.

 

 

35.9

31.3

29.9

30.9

37.3

32.6

31.1

32.2

 

38.8

33.9

32.3

33.4

39.6

34.5

33.0

34.1

40.3

34.2

33.6

34.8

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.78

4.66

4.61

4.59

4.93

4.80

4.75

4.73

 

5.08

4.95

4.89

4.87

5.18

5.04

4.99

4.97

5.27

5.14

5.08

5.06

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

20.6

26.0

28.9

28.5

22.4

28.2

30.6

31.0

 

24.2

30.4

32.3

33.4

25.6

32.3

33.0

34.1

27.1

34.1

33.6

34.8

115 °F

MBH

 

DryEntering °FBulb

 

83

19.7

25.1

28.0

27.6

21.4

27.2

30.1

29.9

 

23.0

29.3

32.3

32.2

24.4

31.0

33.0

33.5

25.8

32.8

33.6

34.8

 

 

1

 

 

 

80

18.7

24.1

27.0

26.6

20.3

26.1

29.3

28.9

 

21.9

28.2

31.6

31.1

23.2

29.8

32.6

32.9

24.5

31.5

33.6

34.8

 

 

 

 

 

 

77

17.8

23.2

26.1

25.7

19.3

25.1

28.2

27.8

 

20.7

27.0

30.4

30.0

22.0

28.6

31.4

31.7

23.2

30.2

32.3

33.5

 

 

 

 

 

 

74

16.9

22.2

25.1

24.8

18.2

24.0

27.2

29.8

 

19.6

25.9

29.3

28.8

20.8

27.4

30.1

30.5

21.9

28.9

31.0

32.2

 

 

 

 

 

 

71

-

21.3

24.2

23.8

-

23.0

26.2

25.7

 

-

24.7

28.1

27.7

-

26.2

28.9

29.3

-

27.6

29.7

30.9

 

 

 

 

 

 

68

-

20.3

23.2

22.9

-

22.0

25.1

24.7

 

-

23.6

27.0

26.5

-

25.0

27.7

28.1

-

26.4

28.5

29.6

 

 

NET

CAP.

 

 

33.0

27.9

27.5

28.9

34.4

29.1

28.7

30.1

 

35.8

30.3

29.8

31.3

36.3

30.7

30.3

31.7

36.9

31.2

30.7

32.2

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

5.05

4.88

4.87

4.83

5.19

5.02

5.01

4.97

 

5.34

5.16

5.15

5.11

5.45

5.27

5.26

5.22

5.57

5.38

5.37

5.33

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

17.7

22.6

26.1

25.3

19.1

24.5

27.9

28.2

 

20.6

26.3

29.8

31.2

23.3

29.4

30.3

31.7

26.0

32.5

30.7

32.2

125 °F

MBH

 

DryEntering °FBulb

 

83

17.8

22.8

25.0

24.3

19.3

24.6

27.4

26.9

 

20.7

26.5

29.8

29.5

22.7

28.8

30.3

30.8

24.8

31.2

30.7

32.2

 

 

1

 

 

 

80

18.0

22.9

25.2

24.4

19.4

24.8

27.2

26.4

 

20.9

26.6

29.3

28.4

22.2

28.3

30.0

30.3

23.5

30.0

30.7

32.2

 

 

 

 

 

 

77

18.1

23.1

25.3

24.6

19.6

24.9

27.4

26.6

 

21.1

26.8

29.4

28.6

21.7

27.8

29.5

29.8

22.3

28.7

29.5

31.0

 

 

 

 

 

 

74

18.3

23.2

25.5

24.8

19.8

25.1

27.5

26.7

 

21.2

27.0

29.6

28.7

21.1

27.2

28.9

29.2

21.0

27.5

28.2

29.7

 

 

 

 

 

 

71

-

23.4

25.6

24.9

-

25.3

27.7

26.9

 

-

27.2

29.8

28.9

-

26.7

28.4

28.7

-

26.2

27.0

28.5

 

 

 

 

 

 

68

-

23.5

25.8

25.1

-

25.4

27.9

27.1

 

-

27.3

29.9

29.1

-

26.2

27.9

28.2

-

25.0

25.8

27.2

1. These capacities are net capacities (the indoor fan heat is deducted). TABLE 5: DNA042 COOLING CAPACITIES - 3-1/2 TON ALL SENSIBLE CAPACITY

10

Johnson Controls Unitary Products

Page 10
Image 10
York 292443-XTG-D-0508 manual DNA042 COOLING CAPACITIES - 3-1/2TON, Johnson Controls Unitary Products