![FIELD-INSTALLED ACCESSORIES](/images/new-backgrounds/35155/3515513x1.webp)
uses an inside CO2 sensor to perform Demand Ventila- tion. It can also use an Outside CO2 sensor to perform Dif- ferential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented
Simplicity®
Novar® BAS CONTROL - The Novar®
JOHNSON CONTROLS BAS CONTROL - The Johnson Control
CPC BAS CONTROL - The Computer Process Controls Model
HONEYWELL BAS CONTROL - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch.
•SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment.
Factory installed smoke detectors in the return air may be subjected to freezing temperatures during “off” times due to outside air infiltration. These smoke detectors have an operation limit of 32°F to 131°F. Smoke detectors installed in areas that could be outside those limitations will have to be moved to prevent having false alarms.
•COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit.
•STAINLESS STEEL HEAT EXCHANGER - For applica- tions in corrosive environments, this option provides a full stainless steel heat exchanger assembly.
•STAINLESS STEEL DRAIN PAN - An optional rust- proof stainless steel drain pan is available to provide years of
•PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an
•HIGH STATIC DRIVE - Includes a belt and blower pulley upgrade to enhance blower performance.
•DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory.
•HINGED FILTER DOOR/”TOOL FREE” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance.
NOTE:Knobs are shipped separately within the unit to prevent shipping damage. These must be field installed for tool free operation.
•HINGED/"TOOL FREE" BLOWER, BLOWER MOTOR, FILTER AND ELECTRIC ACCESS PANELS - This option allows for complete hinged and tool free access to the unit's blower, blower motor, filters and electrical panel sections.
FIELD-INSTALLED ACCESSORIES
•SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a
The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.
The rainhood is painted to match the basic unit and must be
•MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a
The rain hood is painted to match the basic unit and must be field assembled before installing.
•ROOF CURBS -