COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued)
| FURNACE** | COIL |
|
| COOLING |
|
| |||
UNIT MODEL | CFM RANGE | W | MODEL | RATED CFM | NET MBH | SEER | SEER + TXV1 | EER | ||
|
|
|
| TOTAL | SENS. | W/O TXV |
|
| ||
|
| 17 | G1FA048S17 | 1575 | 45.5 | 34.1 | 12.00* | 12.00 | 11.00 | |
|
| 21 | G1FA048S21 | 1575 | 46.5 | 34.9 | 12.00* | 12.00 | 11.00 | |
|
| 21,24 | G1FA060S21,24 | 1575 | 48.0 | 36.0 | 12.50* | 12.50 | 11.10 | |
|
| 21 | G1HA048H21 | 1550 | 46.0 | 33.6 | 12.00* | – | 11.10 | |
|
| 21 | G1HA048H21T | 1525 | 46.0 | 33.6 | – | 12.00* | 11.11 | |
|
| 24 | G1HA060H24 | 1575 | 47.0 | 33.8 | 12.00* | – | 11.10 | |
|
| 24 | G1HA060H24T | 1575 | 47.0 | 33.8 | – | 12.00* | 11.10 | |
|
| - | G1HD048 | 1575 | 46.0 | 34.5 | 12.00* | 12.00 | 10.80 | |
H2RC048S06 | 1375 | - | G1HD060 | 1575 | 47.5 | 35.6 | 12.40* | 12.40 | 11.05 | |
1775 |
|
|
|
|
|
|
|
| ||
21 | G1NA048S21D | 1575 | 46.0 | 34.5 | 12.00* | 12.00 | 10.70 | |||
| ||||||||||
|
| 17 | G1UA048S17 | 1575 | 45.5 | 34.1 | 12.00* | 12.00 | 11.00 | |
|
| 21 | G1UA048S21 | 1575 | 46.5 | 34.9 | 12.00* | 12.00 | 11.00 | |
|
| 21,24 | G1UA060S21,24 | 1575 | 48.0 | 36.0 | 12.50* | 12.50 | 11.10 | |
|
| 17 | G2FD046(S,H)17 | 1575 | 45.5 | 34.1 | 12.00* | 12.00 | 10.80 | |
|
| 21,24 | G2FD048(S,H)21,24 | 1575 | 46.5 | 34.9 | 12.20* | 12.20 | 10.90 | |
|
| 24 | G2FD060(S,H)24 | 1575 | 48.0 | 36.0 | 12.50* | 12.50 | 11.10 | |
|
| 24 | G2FD061H24 | 1575 | 48.5 | 36.4 | 12.50* | 12.50 | 11.20 | |
|
| 17 | G1FA048S17 | 1500 | 44.5 | 32.9 | – | 12.00 | 10.50 | |
|
| 21 | G1FA048S21 | 1600 | 45.5 | 33.7 | – | 12.00 | 11.00 | |
|
| 21,24 | G1FA060S21,24 | 1600 | 47.0 | 34.8 | – | 12.50 | 11.45 | |
|
| - | G1HD048 | 1600 | 45.0 | 33.3 | – | 12.00 | 11.15 | |
|
| - | G1HD060 | 1600 | 46.5 | 36.1 | – | 12.40 | 11.40 | |
| 1400 | 21 | G1NA048S21D | 1400 | 46.0 | 34.0 | – | 12.00 | 11.20 | |
H1RC048S(25,46) | 17 | G1UA048S17 | 1500 | 44.5 | 32.9 | – | 12.00 | 10.50 | ||
1800 | ||||||||||
| 21 | G1UA048S21 | 1600 | 45.5 | 33.7 | – | 12.00 | 11.00 | ||
|
| |||||||||
|
| 21,24 | G1UA060S21,24 | 1600 | 47.0 | 34.8 | – | 12.50 | 11.45 | |
|
| 17 | G2FD046(S,H)17 | 1500 | 44.5 | 32.9 | – | 12.00 | 10.50 | |
|
| 21,24 | G2FD048(S,H)21,24 | 1600 | 45.5 | 33.7 | – | 12.20 | 11.20 | |
|
| 24 | G2FD060(S,H)24 | 1600 | 47.0 | 34.8 | – | 12.50 | 11.45 | |
|
| 24 | G2FD061H24 | 1600 | 47.5 | 35.2 | – | 12.50 | 11.50 | |
|
| 21 | G1FA060S21(T) | 1800 | 56.5 | 43.4 | – | 12.00 | 10.10 | |
|
| - | G1HD060 | 1800 | 55.5 | 42.8 | – | 11.75 | 10.00 | |
| 1600 | 24 | G1NA060S24T | 1800 | 55.5 | 42.1 | – | 11.75 | 10.00 | |
H4RC060S06 | 21 | G1UA060S21(T) | 1800 | 56.5 | 43.4 | – | 12.00 | 10.10 | ||
2200 | ||||||||||
| 24 | G2FD060(S,H)24(T) | 1800 | 56.5 | 43.4 | – | 12.00 | 10.10 | ||
|
| |||||||||
|
| 24 | G2FD061H24 | 1800 | 56.5 | 43.8 | – | 12.00 | 10.15 | |
|
| 24 | G1HA60S24(T) | 1710 | 56.0 | 42.5 | – | 12.00 | 10.15 | |
|
| 21,24 | G1FA060S21,24 | 1800 | 57.5 | 42.6 | – | 12.00 | 10.40 | |
|
| 24 | G1HA060H24T | 1800 | 57.5 | 41.4 | – | 12.00* | 10.40 | |
| 1600 | - | G1HD060 | 2000 | 57.5 | 42.6 | – | 12.00 | 10.25 | |
H2RC060S(25,46) | 24 | G1NA060S24T | 1850 | 57.5 | 38.9 | – | 12.00* | 10.50 | ||
2200 | ||||||||||
| 21,24 | G1UA060S21,24 | 1800 | 57.5 | 42.6 | – | 12.00 | 10.40 | ||
|
| |||||||||
|
| 24 | G2FD060(S,H)24 | 1800 | 57.5 | 42.6 | – | 12.00 | 10.40 | |
|
| 24 | G2FD061H24 | 1850 | 58.0 | 43.2 | – | 12.00 | 10.45 |
1. TXV = Use 1TV700 Series Kit.
*Requires 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace
Unitary Products Group | 9 |