COOLING CAPACITY - With Air Handler Coils
UNIT MODEL | AIR HANDLER |
|
| COIL1 |
|
|
|
| COOLING |
|
| ||
MODEL | ELECTRIC2 |
| W | RATED |
| NET MBH | SEER | SEER | EER | ||||
| HEAT KW |
| MODEL | CFM |
|
|
|
| W/O TXV | WITH TXV3 | |||
|
|
| TOTAL |
| SENS. | ||||||||
|
|
| 1 | PH 12 | SEER AC WITH N1AH / G2FD |
|
|
|
| ||||
H2RC018S06 | N1AHB0806 | 2,5,8,10 |
| 17 | G2FD024(S,H)17 | 600 |
| 19.6 |
| 13.2 | 12.50 | 12.50 | 11.60 |
H2RC024S06 | N1AHB0806 | 2,5,8,10 |
| 17 | G2FD024(S,H)17 | 750 |
| 23.6 |
| 16.9 | 12.00 | 12.00 | 11.00 |
N1AHB0806 | 2,5,8,10 |
| 17 | G2FD030(S,H)17 | 750 |
| 24.0 |
| 17.3 | 12.00 | 12.00 | 11.10 | |
|
|
|
| ||||||||||
H2RC030S06 | N1AHB1206 | 2,5,8,10 |
| 17 | G2FD030(S,H)17 | 1000 |
| 30.0 |
| 21.3 | 12.00 | 12.00 | 11.00 |
N1AHB1206 | 2,5,8,10 |
| 17 | G2FD036(S,H)17 | 1000 |
| 30.6 |
| 21.8 | 12.25 | 12.25 | 11.20 | |
|
|
|
| ||||||||||
H2RC036S06 | N1AHB1206 | 5,8,10,15,19 |
| 17 | G2FD036(S,H)17 | 1200 |
| 33.8 |
| 23.6 | 11.50 | 11.50 | 10.70 |
N1AHB1206 | 5,8,10,15,19 |
| 17 | G2FD046(S,H)17 | 1200 |
| 35.0 |
| 24.4 | 12.00 | 12.00 | 10.90 | |
|
|
|
| ||||||||||
H2RC042S06 | N1AHC1606 | 5,8,10,15,20 |
| 21 | G2FD042(S,H)21 | 1400 |
| 41.0 |
| 29.3 | 12.00 | – | 10.50 |
N1AHC1606 | 5,8,10,15,20 |
| 21 | G2FD048(S,H)21 | 1400 |
| 42.5 |
| 30.6 | 12.00 | – | 10.75 | |
|
|
|
| ||||||||||
H2RC048S06 | N1AHC1606 | 5,8,10,15,20 |
| 21 | G2FD048(S,H)21 | 1575 |
| 46.5 |
| 36.0 | 12.20 | 12.20 | 10.90 |
N1AHD2006 | 8,10,15,20,25,30 |
| 24 | G2FD060(S,H)24 | 1575 |
| 48.0 |
| 36.4 | 12.50 | 12.50 | 11.10 | |
| N1AHD2006 | 8,10,15,20,25,30 |
| 24 | G2FD061H24 | 1575 |
| 48.5 |
| 34.5 | 12.50 | 12.50 | 11.20 |
H3RC060S06 | N1AHD2006 | 8,10,15,20,25,30 |
| 24 | G2FD060(S,H)24 | 1800 |
| 57.5 |
| 42.6 | – | 12.00 | 10.40 |
N1AHD2006 | 8,10,15,20,25,30 |
| 24 | G2FD061H24 | 1850 |
| 58.0 |
| 43.2 | – | 12.00 | 10.45 | |
|
|
|
| ||||||||||
|
|
| 3 | PH 12 | SEER AC WITH N1AH / G2FD |
|
|
|
| ||||
H1RC036S(25,46) | N1AHB1246 | 5,8,10,15,18 |
| 17 | G2FD036(S,H)17 | 1255 |
| 33.6 |
| 24.9 | – | 12.00 | 10.65 |
N1AHB1246 | 5,8,10,15,18 |
| 17 | G2FD046(S,H)17 | 1250 |
| 34.8 |
| 25.8 | – | 12.00 | 10.95 | |
| N1AHC1646 | 5,8,10,15,18 |
| 21 | G2FD048(S,H)21 | 1600 |
| 45.5 |
| 33.7 | – | 12.20 | 11.20 |
H1RC048S(25,46) | N1AHD2046 | 8,10,15,20,25,30 |
| 24 | G2FD060(S,H)24 | 1620 |
| 47.0 |
| 34.8 | – | 12.50 | 11.45 |
N1AHD2046 | 8,10,15,20,25,30 |
| 24 | G2FD061H24 | 1600 |
| 47.5 |
| 35.2 | – | 12.50 | 11.50 | |
|
|
|
| ||||||||||
H1RC060S(25,46) | N1AHD2046 | 8,10,15,20,25,30 |
| 24 | G2FD060(S,H)24(T) | 1800 |
| 56.5 |
| 43.4 | – | 12.00 | 10.10 |
N1AHD2046 | 8,10,15,20,25,30 |
| 24 | G2FD061H24 | 1800 |
| 56.5 |
| 43.8 | – | 12.00 | 10.15 | |
|
|
|
| ||||||||||
|
| 1 PH 12 SEER / N1VS - VARIABLE SPEED |
|
|
|
| |||||||
H2RC018S06 | N1VSB12 | 10,15,18 |
| 17 | G2FD024(S,H)17 | 650 |
| 20.2 |
| 13.2 | 13.75 | 13.75 | 12.80 |
H2RC024S06 | N1VSB12 | 10,15,18 |
| 17 | G2FD024(S,H)17 | 725 |
| 24.2 |
| 16.9 | 13.35 | 13.35 | 12.15 |
N1VSB12 | 10,15,18 |
| 17 | G2FD036(S,H)17 | 775 |
| 25.2 |
| 17.8 | 13.50 | 13.50 | 12.50 | |
|
|
|
| ||||||||||
H2RC030S06 | N1VSB12 | 10,15,18 |
| 17 | G2FD036(S,H)17 | 1000 |
| 31.0 |
| 21.9 | 13.25 | 13.25 | 12.15 |
N1VSB12 | 10,15,18 |
| 17 | G2FD046(S,H)17 | 1000 |
| 32.0 |
| 22.3 | 13.75 | 13.75 | 12.55 | |
| N1VSB12 | 10,15,18 |
| 17 | G2FD046(S,H)17 | 1000 |
| 32.0 |
| 22.3 | 13.75 | 13.75 | 12.55 |
H2RC036S06 | N1VSB12 | 10,15,18 |
| 17 | G2FD036(S,H)17 | 1200 |
| 34.8 |
| 23.6 | 12.40 | 12.40 | 11.35 |
N1VSB12 | 10,15,18 |
| 17 | G2FD046(S,H)17 | 1210 |
| 35.8 |
| 24.4 | 13.00 | 13.00 | 11.65 | |
| N1VSC16 | 10,15,18 |
| 21 | G2FD048(S,H)21 | 1155 |
| 36.8 |
| 25.1 | 13.40 | 13.40 | 12.20 |
H2RC042S06 | N1VSC16 | 10,15,18 |
| 21 | G2FD048(S,H)21 | 1400 |
| 43.0 |
| 30.6 | 13.00 | – | 11.55 |
N1VSC16 | 10,15,18 |
| 21 | G2FD048(S,H)21 | 1590 |
| 47.0 |
| 30.6 | 12.80 | – | 11.40 | |
|
|
|
| ||||||||||
H2RC048S06 | N1VSC16 | 10,15,18 |
| 21 | G2FD048(S,H)21 | 1590 |
| 47.0 |
| 34.9 | 12.80 | 12.80 | 11.40 |
N1VSD20 | 10,15,18,30 |
| 24 | G2FD060(S,H)24 | 1560 |
| 48.5 |
| 36.0 | 13.25 | 13.25 | 11.75 | |
| N1VSD20 | 10,15,18,30 |
| 24 | G2FD061H24 | 1560 |
| 49.0 |
| 36.4 | 13.30 | 13.30 | 11.90 |
H3RC060S06 | N1VSD20 | 10,15,18,30 |
| 24 | G2FD060(S,H)24 | 1780 |
| 56.0 |
| 42.3 | – | 12.10 | 10.25 |
N1VSD20 | 10,15,18,30 |
| 24 | G2FD061H24 | 1780 |
| 56.5 |
| 42.7 | – | 12.25 | 10.40 | |
|
|
|
| ||||||||||
|
|
| 1 | PH 12 SEER AC / F2RP / RC / FC4,5 |
|
|
|
|
|
| |||
H2RC018S06 | F2RC/F2FC024 | 5,8,10 |
| 18 | – | 600 |
| 20.0 |
| 13.2 | 12.50 | 12.50 | 11.70 |
F2RP/F2FP024 | 5,8,10 |
| 18 | – | 600 |
| 20.0 |
| 13.2 | 12.50 | 12.50 | 11.70 | |
|
|
|
| ||||||||||
| F2RC/F2FC024 | 5,8,10 |
| 18 | – | 750 |
| 23.4 |
| 17.5 | 11.50 | 11.50 | 10.85 |
H2RC024S06 | F2RC/F2FC030 | 5,8,10,15 |
| 18 | – | 750 |
| 23.4 |
| 17.5 | 11.50 | 11.50 | 10.85 |
F2RP/F2FP024 | 5,8,10 |
| 18 | – | 750 |
| 23.6 |
| 17.5 | 12.00 | 12.00 | 10.90 | |
|
|
|
| ||||||||||
| F2RP/F2FP030 | 5,8,10,15 |
| 18 | – | 750 |
| 24.0 |
| 17.9 | 12.00 | 12.00 | 11.10 |
| F2RC/F2FC030 | 5,8,10,15 |
| 18 | – | 1000 |
| 29.8 |
| 21.5 | 12.00 | 12.00 | 11.00 |
H2RC030S06 | F2RC/F2FC036 | 5,8,10,15 |
| 21 | – | 1000 |
| 31.0 |
| 22.4 | 12.25 | 12.25 | 11.30 |
F2RP/F2FP030 | 5,8,10,15 |
| 18 | – | 1000 |
| 30.2 |
| 22.9 | 12.00 | 12.00 | 11.15 | |
|
|
|
| ||||||||||
| F2RP/F2FP036 | 5,8,10,15,19 |
| 21 | – | 1000 |
| 30.2 |
| 23.5 | 12.00 | 12.00 | 11.15 |
| F2RC/F2FC036 | 5,8,10,15 |
| 21 | – | 1200 |
| 34.6 |
| 26.2 | 12.00 | 12.00 | 10.85 |
H2RC036S06 | F2RP/F2FP036 | 5,8,10,15,19 |
| 21 | – | 1200 |
| 34.6 |
| 26.2 | 12.00 | 12.00 | 10.85 |
F2RP/F2FP042 | 5,8,10,15 |
| 21 | – | 1200 |
| 34.8 |
| 26.3 | 11.60 | 11.60 | 10.70 | |
|
|
|
| ||||||||||
| F2FP048 | 5,8,10,15,20,25 |
| 24 | – | 1200 |
| 35.4 |
| 26.7 | 12.00 | 12.00 | 10.90 |
H2RC042S06 | F2RP/F2FP042 | 5,8,10,15 |
| 21 | – | 1400 |
| 40.5 |
| 28.9 | 11.80 | – | 10.35 |
F2FP048 | 5,8,10,15,20,25 |
| 24 | – | 1400 |
| 42.5 |
| 30.5 | 12.00 | – | 10.55 | |
|
|
|
| ||||||||||
H2RC048S06 | F2FP048 | 5,8,10,15,20,25 |
| 24 | – | 1565 |
| 46.5 |
| 34.9 | 11.40 | 11.40 | 10.75 |
F2FP060 | 5,8,10,15,20,25 |
| 24 | – | 1575 |
| 48.0 |
| 35.9 | 11.50 | 11.50 | 10.70 | |
| F2FV060 | 8,10,15,20,25 |
| 24 | – | 1560 |
| 48.5 |
| 35.9 | 13.20 | 13.20 | 11.70 |
H3RC060S06 | F2FP060 | 5,8,10,15,20,25 |
| 24 | – | 1800 |
| 56.0 |
| 42.0 | – | 12.00 | 10.00 |
F2FV060 | 8,10,15,20,25 |
| 24 | – | 1780 |
| 56.0 |
| 42.3 | – | 12.10 | 10.30 | |
|
|
|
| ||||||||||
Rated in accordance | with DOE test | procedures (Federal Register |
|
|
|
|
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in
1.G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2.Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3.TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.
4.To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.
5.FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable.