ZF102 (8.5 Ton) (Continued)
Air on |
|
|
|
|
|
| Temperature of Air on Condenser Coil |
|
|
|
|
|
| |||||
Evaporator Coil | Total | Total |
| Sensible Capacity (MBh) |
| Total | Total |
| Sensible Capacity (MBh) |
| ||||||||
CFM |
| WB | Capacity1 | Input |
| Return Dry Bulb (°F) |
| Capacity1 | Input |
| Return Dry Bulb (°F) |
| ||||||
| (°F) | (MBh) | (kW)2 |
|
|
|
|
|
| (MBh) | (kW)2 |
|
|
|
|
|
| |
| 90 | 85 | 80 | 75 | 70 | 65 | 90 | 85 | 80 | 75 | 70 | 65 | ||||||
|
|
|
|
|
| 115°F |
|
|
|
|
|
|
| 125°F |
|
|
|
|
|
| 77 | 98.1 | 9.8 | 38.6 | 35.3 | 26.2 | - | - | - | 89.4 | 10.5 | 38.9 | 30.9 | 23.7 | - | - | - |
2125 |
| 72 | 88.7 | 9.5 | 57.8 | 48.7 | 39.5 | 30.4 | - | - | 80.2 | 10.1 | 54.9 | 45.8 | 36.7 | 27.6 | - | - |
| 67 | 79.2 | 9.2 | 77.0 | 62.0 | 52.8 | 43.7 | 34.6 | - | 70.9 | 9.7 | 70.9 | 58.8 | 49.7 | 40.6 | 31.4 | - | |
|
| |||||||||||||||||
|
| 62 | 75.1 | 9.0 | 75.1 | 75.1 | 62.5 | 53.4 | 44.2 | 35.1 | 68.8 | 9.6 | 68.8 | 68.8 | 57.6 | 48.4 | 39.3 | 30.2 |
|
| 77 | 101.4 | 9.9 | 50.6 | 39.9 | 29.2 | - | - | - | 91.9 | 10.6 | 51.5 | 37.0 | 26.4 | - | - | - |
|
| 72 | 91.6 | 9.6 | 65.5 | 54.7 | 44.0 | 33.3 | - | - | 82.4 | 10.2 | 62.2 | 51.5 | 40.9 | 30.2 | - | - |
2550 |
| 67 | 81.8 | 9.3 | 80.3 | 69.6 | 58.9 | 48.2 | 37.5 | - | 72.9 | 9.8 | 72.9 | 66.1 | 55.4 | 44.8 | 34.1 | - |
|
| 62 | 77.6 | 9.1 | 77.6 | 77.6 | 69.7 | 59.0 | 48.3 | 37.6 | 70.7 | 9.7 | 70.7 | 70.7 | 64.2 | 53.5 | 42.9 | 32.2 |
|
| 57 | 78.2 | 9.1 | 78.2 | 78.2 | 67.7 | 57.0 | 46.3 | 35.6 | 71.3 | 9.7 | 71.3 | 71.3 | 61.4 | 50.7 | 40.1 | 29.4 |
|
| 77 | 104.6 | 10.0 | 62.6 | 44.5 | 32.2 | - | - | - | 94.4 | 10.7 | 64.1 | 43.2 | 29.1 | - | - | - |
|
| 72 | 94.5 | 9.7 | 73.1 | 60.8 | 48.6 | 36.3 | - | - | 84.6 | 10.3 | 69.5 | 57.3 | 45.1 | 32.9 | - | - |
2975 |
| 67 | 84.4 | 9.4 | 83.6 | 77.2 | 64.9 | 52.7 | 40.4 | - | 74.8 | 9.9 | 74.8 | 73.3 | 61.1 | 48.9 | 36.8 | - |
|
| 62 | 80.0 | 9.2 | 80.0 | 80.0 | 76.8 | 64.6 | 52.3 | 40.0 | 72.6 | 9.8 | 72.6 | 72.6 | 70.8 | 58.6 | 46.4 | 34.3 |
|
| 57 | 80.7 | 9.2 | 80.7 | 80.7 | 74.7 | 62.4 | 50.2 | 37.9 | 73.3 | 9.8 | 73.3 | 73.3 | 67.7 | 55.6 | 43.4 | 31.2 |
|
| 77 | 107.8 | 10.1 | 74.5 | 49.0 | 35.2 | - | - | - | 96.8 | 10.8 | 76.7 | 49.3 | 31.8 | - | - | - |
|
| 72 | 97.4 | 9.8 | 80.8 | 66.9 | 53.1 | 39.3 | - | - | 86.8 | 10.4 | 76.7 | 63.0 | 49.3 | 35.6 | - | - |
3400 |
| 67 | 87.0 | 9.5 | 87.0 | 84.8 | 71.0 | 57.2 | 43.3 | - | 76.7 | 10.1 | 76.7 | 76.7 | 66.8 | 53.1 | 39.4 | - |
|
| 62 | 82.5 | 9.3 | 82.5 | 82.5 | 84.0 | 70.2 | 56.3 | 42.5 | 74.5 | 9.9 | 74.5 | 74.5 | 74.5 | 63.7 | 50.0 | 36.3 |
|
| 57 | 83.2 | 9.3 | 83.2 | 83.2 | 81.6 | 67.8 | 54.0 | 40.2 | 75.2 | 9.9 | 75.2 | 75.2 | 74.1 | 60.4 | 46.7 | 33.0 |
|
| 72 | 95.3 | 9.8 | 86.8 | 71.6 | 56.5 | 41.4 | - | - | 83.9 | 10.5 | 82.5 | 67.6 | 52.6 | 37.6 | - | - |
3825 |
| 67 | 85.1 | 9.5 | 85.1 | 84.0 | 75.6 | 60.5 | 45.3 | - | 74.1 | 10.1 | 74.1 | 74.1 | 71.2 | 56.2 | 41.2 | - |
| 62 | 80.7 | 9.3 | 80.7 | 80.7 | 81.5 | 66.3 | 51.2 | 36.1 | 72.1 | 10.0 | 72.1 | 72.1 | 72.1 | 58.5 | 43.5 | 28.5 | |
|
| |||||||||||||||||
|
| 57 | 81.4 | 9.4 | 81.4 | 81.4 | 80.6 | 65.5 | 50.4 | 35.3 | 72.7 | 10.0 | 72.7 | 72.7 | 72.1 | 57.1 | 42.1 | 27.2 |
|
| 72 | 93.2 | 9.9 | 92.7 | 76.3 | 59.9 | 43.5 | - | - | 81.0 | 10.6 | 81.0 | 72.1 | 55.8 | 39.6 | - | - |
4250 |
| 67 | 83.2 | 9.6 | 83.2 | 83.2 | 80.2 | 63.8 | 47.4 | - | 71.5 | 10.2 | 71.5 | 71.5 | 71.5 | 59.3 | 43.1 | - |
| 62 | 78.9 | 9.4 | 78.9 | 78.9 | 78.9 | 62.5 | 46.1 | 29.7 | 69.6 | 10.0 | 69.6 | 69.6 | 69.6 | 53.3 | 37.0 | 20.8 | |
|
| |||||||||||||||||
|
| 57 | 79.6 | 9.4 | 79.6 | 79.6 | 79.6 | 63.2 | 46.8 | 30.4 | 70.2 | 10.1 | 70.2 | 70.2 | 70.2 | 53.9 | 37.6 | 21.4 |
1.These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.
2.These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
22 | Johnson Controls Unitary Products |