528194-YTG-F-1210

ZF120 (10 Ton) Side Duct

Air Flow

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

0.2

 

0.4

0.6

0.8

1.0

1.2

 

1.4

1.6

 

1.8

 

2.0

 

(CFM)

 

 

 

 

 

RPM BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

 

 

Field Supplied Drive

 

 

 

Standard 2 HP & Drive

 

 

 

Hi Static 3 HP & Drive

 

2600

675

0.53

726

0.74

776

0.94

824

1.12

870

1.30

914

1.48

957

1.65

1000

1.82

1041

1.99

1082

2.17

2800

686

0.63

738

0.84

787

1.04

835

1.23

881

1.41

925

1.58

969

1.76

1011

1.93

1052

2.10

1093

2.27

3000

699

0.75

750

0.96

800

1.16

847

1.34

893

1.52

938

1.70

981

1.87

1024

2.04

1065

2.21

1106

2.39

3200

713

0.88

764

1.09

814

1.28

861

1.47

907

1.65

952

1.83

995

2.00

1037

2.17

1079

2.34

1119

2.52

3400

728

1.02

779

1.23

829

1.43

877

1.61

923

1.79

967

1.97

1010

2.14

1053

2.31

1094

2.48

1135

2.66

3600

745

1.18

796

1.39

846

1.59

893

1.77

939

1.95

984

2.13

1027

2.30

1069

2.47

1111

2.64

1152

2.82

3800

763

1.36

815

1.57

864

1.76

912

1.95

958

2.13

1002

2.31

1046

2.48

1088

2.65

1129

2.82

1170

3.00

4000

783

1.55

835

1.76

884

1.96

932

2.15

978

2.33

1022

2.50

1066

2.67

1108

2.84

1149

3.02

1190

3.19

4200

805

1.77

856

1.98

906

2.17

953

2.36

999

2.54

1044

2.72

1087

2.89

1129

3.06

1171

3.23

1211

3.41

4400

828

2.00

879

2.21

929

2.41

976

2.59

1022

2.77

1067

2.95

1110

3.12

1152

3.29

-

-

-

-

4600

852

2.25

904

2.46

953

2.66

1001

2.85

1047

3.03

1092

3.20

1135

3.37

-

-

-

-

-

-

4800

879

2.52

930

2.73

980

2.93

1027

3.12

1073

3.30

-

-

-

-

-

-

-

-

-

-

5000

906

2.81

958

3.02

1007

3.22

1055

3.41

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 HP & Field Supplied Drive

 

 

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.932.

ZF150 (12.5 Ton) Side Duct

Air Flow

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

 

1.8

 

2.0

 

(CFM)

 

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM BHP

RPM BHP

 

 

 

 

3 HP & Field

Supplied Drive

 

 

 

 

 

Standard 3 HP & Drive

 

 

 

 

 

3200

684

1.00

741

1.16

794

1.32

844

1.48

892

1.65

940

1.81

988

1.97

1036

2.12

1087

2.27

1141

2.42

3400

709

1.15

765

1.30

818

1.46

868

1.62

916

1.79

964

1.95

1012

2.11

1061

2.26

1112

2.42

1166

2.56

3600

734

1.30

791

1.46

844

1.62

894

1.78

942

1.94

990

2.10

1038

2.26

1087

2.42

1137

2.57

1191

2.72

3800

761

1.48

818

1.63

871

1.79

921

1.95

969

2.12

1017

2.28

1065

2.44

1114

2.59

1164

2.75

1218

2.89

4000

789

1.66

846

1.82

899

1.98

949

2.14

997

2.31

1045

2.47

1093

2.63

1142

2.78

1192

2.93

1246

3.08

4200

818

1.87

875

2.03

928

2.19

978

2.35

1026

2.51

1074

2.67

1121

2.83

1170

2.99

1221

3.14

1275

3.29

4400

847

2.09

904

2.25

957

2.41

1007

2.57

1055

2.73

1103

2.90

1151

3.06

1199

3.21

1250

3.36

1304

3.51

4600

877

2.33

934

2.49

986

2.65

1036

2.81

1085

2.97

1132

3.14

1180

3.29

1229

3.45

1280

3.60

1334

3.75

4800

907

2.59

963

2.75

1016

2.91

1066

3.07

1115

3.23

1162

3.39

1210

3.55

1259

3.71

1310

3.86

1364

4.01

5000

937

2.86

993

3.02

1046

3.18

1096

3.34

1145

3.50

1192

3.66

1240

3.82

1289

3.98

1340

4.13

1394

4.28

5200

967

3.15

1023

3.31

1076

3.47

1126

3.63

1175

3.79

1222

3.95

1270

4.11

1319

4.27

1370

4.42

1424

4.57

5400

997

3.45

1053

3.61

1106

3.77

1156

3.93

1205

4.09

1252

4.26

1300

4.41

1349

4.57

1400

4.72

1454

4.87

5600

1027

3.77

1083

3.93

1136

4.09

1186

4.25

1235

4.41

1282

4.57

1330

4.73

1379

4.89

1430

5.04

1484

5.19

5800

1057

4.11

1113

4.26

1166

4.42

1216

4.59

1264

4.75

1312

4.91

1360

5.07

1409

5.22

-

-

-

-

6000

1086

4.46

1143

4.61

1196

4.77

1246

4.93

1294

5.10

1342

5.26

-

-

-

-

-

-

-

-

6200

1116

4.82

1172

4.98

1225

5.14

1275

5.30

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

Hi Static 5 HP & Drive

 

 

 

 

 

 

5 HP & Field Supplied Drive

 

 

 

 

1.Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.932.

28

Johnson Controls Unitary Products

Page 28
Image 28
York R-410A manual ZF120 10 Ton Side Duct, ZF150 12.5 Ton Side Duct, Available External Static Pressure IWG1

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.