Electrical Data - 3 Comp Standard Efficiency

Model No./Nameplate

 

 

 

 

 

System 1

 

 

 

 

 

 

 

System 2

 

Std. & Ultra Quiet Cond. Fans

High Head/Static Cond. Fans

Two-Speed Cond. Fans

Std. & Ultra Quiet Cond. Fans

 

 

 

 

 

 

 

 

Input Volts

 

Comp.

Condenser Fans

Comp.

Condenser Fans

Comp.

 

Condenser Fans

Comp.

Condenser Fans

 

YCIV S/P

Input Freq

RLA (5)

Qty.

FLA (EA)

RLA (5)

Qty.

 

FLA (EA)

RLA (5)

 

Qty.

 

FLA (EA)

RLA (5)

Qty.

 

FLA (EA)

 

 

 

(9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0287

 

460

60

146

5

2.8

 

 

 

 

 

 

 

 

 

 

 

 

164

4

 

 

2.8

 

 

380

60

184

5

3.5

184

5

 

 

9.3

 

 

 

 

 

 

207

4

 

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1070

 

400

50

175

5

3.1

175

5

 

 

9.3

186

 

5

 

3.8

196

4

 

 

3.1

 

0307

 

460

60

147

5

2.8

 

 

 

 

 

 

 

 

 

 

 

 

147

5

 

 

2.8

 

 

380

60

186

5

3.5

186

5

 

 

9.3

 

 

 

 

 

 

186

5

 

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1180

 

400

50

177

5

3.1

177

5

 

 

9.3

188

 

5

 

3.8

177

5

 

 

3.1

 

0357

 

460

60

160

5

2.8

 

 

 

 

 

 

 

 

 

 

 

 

160

5

 

 

2.8

 

 

380

60

202

5

3.5

202

5

 

 

9.3

 

 

 

 

 

 

202

5

 

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1340

 

400

50

192

5

3.1

192

5

 

 

9.3

204

 

5

 

3.8

192

5

 

 

3.1

 

0397

 

460

60

191

6

2.8

 

 

 

 

 

 

 

 

 

 

 

 

191

6

 

 

2.8

 

 

380

60

241

6

3.5

241

6

 

 

9.3

 

 

 

 

 

 

241

6

 

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

400

50

229

6

3.1

229

6

 

 

9.3

243

 

6

 

3.8

229

6

 

 

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Short Circuit

 

 

 

 

 

 

Field Wiring & Protection

 

 

 

 

 

 

 

 

 

 

 

 

Withstand (KA)

 

 

 

Std. & Ultra Quiet Cond. Fans

 

 

High Head/High Static Fans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YCIV S/P

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended

 

 

 

 

 

 

 

 

 

Recommended

 

 

KVA (7)

 

 

 

 

Minimum Ckt.

 

Max. Inverse

 

Max Dual

Minimum Ckt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Block

Circuit Breaker

Ampacity (MCA)

 

 

Fuse/Ckt.

Time Ckt. Brkr.

Element Fuse

Ampacity (MCA)

 

 

Fuse/Ckt.

 

 

 

 

 

 

(STD)

 

 

(OPT)

(3)

 

 

Breaker Rating

Rating (2)

 

 

Size (2)

(3)

 

 

Breaker Rating

 

 

 

 

 

 

 

 

 

 

 

 

 

(4)

 

 

 

 

 

(4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0287

 

 

 

2.4

30KA

 

 

65KA

494

 

 

 

600

600

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

2.4

30KA

 

 

65KA

624

 

 

 

700

800

 

 

 

800

676

 

 

 

800

 

1070

 

 

 

2.4

30KA

 

 

65KA

590

 

 

 

700

700

 

 

 

700

671

 

 

 

800

 

0307

 

 

 

2.4

30KA

 

 

65KA

540

 

 

 

600

700

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

2.4

30KA

 

 

65KA

682

 

 

 

800

800

 

 

 

800

731

 

 

 

800

 

1180

 

 

 

2.4

30KA

 

 

65KA

644

 

 

 

700

800

 

 

 

800

731

 

 

 

800

 

0357

 

 

 

2.4

30KA

 

 

65KA

607

 

 

 

700

800

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

2.4

30KA

 

 

65KA

766

 

 

 

1000

1000

 

 

 

1000

827

 

 

 

1000

 

1340

 

 

 

2.4

30KA

 

 

65KA

724

 

 

 

800

800

 

 

 

800

824

 

 

 

1000

 

0397

 

 

 

2.4

30KA

 

 

65KA

671

 

 

 

800

800

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

2.4

30KA

 

 

65KA

847

 

 

 

1000

1000

 

 

 

1000

911

 

 

 

1000

 

1500

 

 

 

2.4

30KA

 

 

65KA

801

 

 

 

1000

1000

 

 

 

1000

913

 

 

 

1000

 

See page 192 for Electrical Data footnotes.

120

JOHNSON CONTROLS

Page 120
Image 120
York R134A manual Electrical Data 3 Comp Standard Efficiency, Fla Ea

R134A specifications

York R134A is a widely recognized refrigerant that has become a staple in the heating, ventilation, and air conditioning (HVAC) industry. It is a hydrofluorocarbon (HFC) compound, specifically known as 1,1,1,2-tetrafluoroethane. This refrigerant was introduced as a substitute for R12, a chlorofluorocarbon (CFC) that was phased out due to its harmful effects on the ozone layer.

One of the main features of York R134A is its non-ozone-depleting properties, making it a more environmentally friendly option compared to its predecessors. This characteristic aligns with global efforts to reduce the impact of refrigerants on climate change and ozone layer depletion. As a result, R134A has found extensive applications in both residential and commercial cooling systems.

In terms of thermodynamic properties, R134A boasts a moderate cooling capacity and is known for its energy efficiency, which translates to lower operating costs for HVAC systems. It operates efficiently under a wide temperature range, making it suitable for various applications, from automotive air conditioning to commercial refrigeration and chillers.

York R134A also exhibits excellent stability and compatibility with lubricants and materials commonly used in HVAC systems, such as synthetic oils. This compatibility helps reduce wear and tear on components, prolonging the lifespan of the equipment. Additionally, its low toxicity and flammability risk make it a safer choice for technicians and end-users alike.

Technologically, York R134A systems often feature advanced controls and monitoring tools that optimize refrigerant flow and enhance energy efficiency. This includes digital thermostats and automation systems that adjust cooling performance based on real-time environmental conditions.

In summary, York R134A stands out for its non-ozone-depleting characteristics, energy efficiency, and compatibility with HVAC technologies. These features, combined with its broad application range and safety profile, have established R134A as a preferred refrigerant in the modern refrigeration landscape, helping to meet both environmental standards and performance expectations in cooling systems worldwide.