FORM 201.23-EG1 (1007)

 

 

 

 

 

System 2

 

 

 

 

 

 

 

 

 

 

 

 

System 3

 

 

 

 

 

 

 

High Head/Static Cond. Fans

Two-Speed Cond. Fans

Std. & Ultra Quiet Cond. Fans

High Head/Static Cond. Fans

Two-Speed Cond. Fans

Comp.

 

Condenser Fans

Comp.

Condenser Fans

Comp.

 

Condenser Fans

Comp.

Condenser Fans

Comp.

Condenser Fans

RLA (5)

 

Qty.

 

FLA (EA)

RLA (5)

Qty.

 

FLA (EA)

RLA (5)

 

Qty.

 

FLA (EA)

RLA (5)

Qty.

FLA (EA)

RLA (5)

Qty.

FLA (EA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

108

 

4

 

2.8

 

 

 

 

 

 

 

 

 

 

207

 

4

 

9.3

 

 

 

 

 

 

136

 

4

 

3.5

136

4

9.3

 

 

 

 

 

 

196

 

4

 

9.3

202

4

 

 

3.8

129

 

4

 

3.1

129

4

9.3

 

135

4

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

165

 

4

 

2.8

 

 

 

 

 

 

 

 

 

 

186

 

5

 

9.3

 

 

 

 

 

 

208

 

4

 

3.5

208

4

9.3

 

 

 

 

 

 

177

 

5

 

9.3

188

5

 

 

3.8

198

 

4

 

3.1

198

4

9.3

 

203

4

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

193

 

6

 

2.8

 

 

 

 

 

 

 

 

 

 

202

 

5

 

9.3

 

 

 

 

 

 

244

 

6

 

3.5

244

6

9.3

 

 

 

 

 

 

192

 

5

 

9.3

204

5

 

 

3.8

232

 

6

 

3.1

232

6

9.3

 

245

6

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

191

 

6

 

2.8

 

 

 

 

 

 

 

 

 

 

241

 

6

 

9.3

 

 

 

 

 

 

241

 

6

 

3.5

241

6

9.3

 

 

 

 

 

 

229

 

6

 

9.3

243

6

 

 

3.8

229

 

6

 

3.1

229

6

9.3

 

243

6

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Wiring & Protection

 

 

 

 

 

 

 

 

 

Field Wiring Lugs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Head/High Static Fans

 

 

 

 

Two-Speed Cond. Fans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Inverse

 

Max Dual

Minimum Ckt.

 

Recommended

Max. Inverse

 

Max Dual

STD Terminal Block

 

OPT Circuit Breaker

 

 

 

 

Fuse/Ckt.

 

 

 

 

 

 

 

 

 

 

 

Time Ckt. Brkr.

Element Fuse

Ampacity (MCA)

 

 

Time Ckt. Brkr.

Element Fuse

 

 

 

 

 

 

 

 

 

 

 

Breaker Rating

 

 

 

 

 

 

 

 

 

 

Rating (2)

 

 

Size (2)

(3)

 

 

 

(4)

Rating (2)

 

 

Size (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lugs/ Phase (1)

Lug Wire Range

Lugs/ Phase (1)

Lug Wire Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

800

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

800

 

 

 

800

623

 

 

 

700

800

 

 

 

800

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

800

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

800

 

 

 

800

683

 

 

 

800

800

 

 

 

800

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

1000

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

1000

 

 

 

1000

776

 

 

 

1000

1000

 

 

 

1000

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

1000

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

1000

 

 

 

1000

857

 

 

 

1000

1000

 

 

 

1000

4

 

#2 - 600 KCM

 

4

 

#4/0 - 500 KCM

 

JOHNSON CONTROLS

121

Page 121
Image 121
York R134A manual Form 201.23-EG1 System, Field Wiring Lugs, STD Terminal Block OPT Circuit Breaker

R134A specifications

York R134A is a widely recognized refrigerant that has become a staple in the heating, ventilation, and air conditioning (HVAC) industry. It is a hydrofluorocarbon (HFC) compound, specifically known as 1,1,1,2-tetrafluoroethane. This refrigerant was introduced as a substitute for R12, a chlorofluorocarbon (CFC) that was phased out due to its harmful effects on the ozone layer.

One of the main features of York R134A is its non-ozone-depleting properties, making it a more environmentally friendly option compared to its predecessors. This characteristic aligns with global efforts to reduce the impact of refrigerants on climate change and ozone layer depletion. As a result, R134A has found extensive applications in both residential and commercial cooling systems.

In terms of thermodynamic properties, R134A boasts a moderate cooling capacity and is known for its energy efficiency, which translates to lower operating costs for HVAC systems. It operates efficiently under a wide temperature range, making it suitable for various applications, from automotive air conditioning to commercial refrigeration and chillers.

York R134A also exhibits excellent stability and compatibility with lubricants and materials commonly used in HVAC systems, such as synthetic oils. This compatibility helps reduce wear and tear on components, prolonging the lifespan of the equipment. Additionally, its low toxicity and flammability risk make it a safer choice for technicians and end-users alike.

Technologically, York R134A systems often feature advanced controls and monitoring tools that optimize refrigerant flow and enhance energy efficiency. This includes digital thermostats and automation systems that adjust cooling performance based on real-time environmental conditions.

In summary, York R134A stands out for its non-ozone-depleting characteristics, energy efficiency, and compatibility with HVAC technologies. These features, combined with its broad application range and safety profile, have established R134A as a preferred refrigerant in the modern refrigeration landscape, helping to meet both environmental standards and performance expectations in cooling systems worldwide.