398612-YTG-B-0608

HEATING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT

VARIABLE

COIL1

 

 

ARI HEATING2

 

 

SPEED

 

 

 

 

 

 

 

MODEL

MODEL

 

47°F

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

 

 

 

PV8*A12

FC/MC/PC/UC37A

34.0

3.66

2.68

20.0

2.56

2.31

8.65

 

PV9*A12

FC/MC/PC/UC37A

34.0

3.60

2.76

20.0

2.54

2.35

8.55

 

PV8*B16

FC/MC/PC/UC43B

33.0

3.74

2.61

20.0

2.62

2.23

8.80

 

PV8*C16

FC/MC/PC/UC43C

33.0

3.76

2.60

20.0

2.64

2.21

8.85

 

PV8*C20

FC/MC/PC/UC43C

33.0

3.70

2.64

20.0

2.60

2.25

8.75

 

P(C,V)9*B12

FC/MC/PC/UC43B

34.0

3.68

2.67

20.0

2.58

2.29

8.70

 

P(C,V)9*C16

FC/MC/PC/UC43C

33.0

3.74

2.61

20.0

2.62

2.23

8.80

 

P(C,V)9*C20

FC/MC/PC/UC43C

33.0

3.74

2.61

20.0

2.62

2.23

8.80

YHJD36S21S1

PV8*C16

FC/MC/PC/UC48C

33.0

3.78

2.57

20.0

2.66

2.19

8.90

 

PV8*C20

FC/MC/PC/UC48C

33.0

3.72

2.63

20.0

2.60

2.25

8.75

 

P(C,V)9*C16

FC/MC/PC/UC48C

33.0

3.76

2.60

20.0

2.64

2.21

8.85

 

P(C,V)9*C20

FC/MC/PC/UC48C

33.0

3.76

2.60

20.0

2.64

2.21

8.85

 

P(C,V)9*D20

FC/MC/PC/UC48D

33.0

3.76

2.60

20.0

2.64

2.21

8.85

 

PV8*C16

HC42

33.0

3.76

2.58

20.0

2.64

2.21

8.85

 

PV8*C20

HC42

33.0

3.72

2.63

20.0

2.60

2.25

8.75

 

P(C,V)9*C16

HC42

33.0

3.74

2.61

20.0

2.62

2.23

8.80

 

P(C,V)9*C20

HC42

33.0

3.76

2.60

20.0

2.64

2.21

8.85

 

PV8*C16

FC/MC/PC/UC48C

41.0

3.62

3.31

25.0

2.68

2.68

8.70

 

PV8*C20

FC/MC/PC/UC48C

41.0

3.64

3.30

24.0

2.70

2.64

8.75

 

P(C,V)9*C16

FC/MC/PC/UC48C

41.0

3.60

3.33

25.0

2.66

2.70

8.65

 

P(C,V)9*C20

FC/MC/PC/UC48C

41.0

3.62

3.31

25.0

2.68

2.68

8.70

YHJD42S21S1

P(C,V)9*D20

FC/MC/PC/UC48D

41.0

3.60

3.33

25.0

2.68

2.68

8.70

PV8*C16

FC/PC/UC60C

41.0

3.62

3.31

24.0

2.68

2.66

8.70

 

 

PV8*C20

FC/PC/UC60C

41.0

3.64

3.30

24.0

2.70

2.64

8.75

 

P(C,V)9*C16

FC/PC/UC60C

41.0

3.60

3.33

25.0

2.66

2.70

8.65

 

P(C,V)9*C20

FC/PC/UC60C

41.0

3.62

3.31

24.0

2.68

2.66

8.70

 

P(C,V)9*D20

FC/MC/PC/UC60D

41.0

3.62

3.31

25.0

2.68

2.68

8.70

 

PV8*C16

FC/PC/UC60C

48.0

3.42

4.06

37.0

2.76

3.92

7.80

 

PV8*C20

FC/PC/UC60C

48.0

3.44

4.04

37.0

2.78

3.92

8.00

 

P(C,V)9*C16

FC/PC/UC60C

47.0

3.40

4.05

37.0

2.76

3.97

7.80

YHJD48S21S1

P(C,V)9*C20

FC/PC/UC60C

48.0

3.42

4.06

37.0

2.76

3.94

8.00

P(C,V)9*D20

FC/MC/PC/UC60D

48.0

3.44

4.04

37.0

2.78

3.92

8.00

 

 

PV8*C20

FC/MC62D

48.0

3.44

4.04

37.0

2.78

3.92

8.00

 

P(C,V)9*C20

FC/MC62D

48.0

3.42

4.06

37.0

2.76

3.94

8.00

 

P(C,V)9*D20

FC/MC62D

48.0

3.44

4.04

37.0

2.78

3.92

8.00

 

PV8*C20

FC/MC62D

58.0

3.48

4.84

39.0

2.38

4.80

7.70

YHJD60S21S1

P(C,V)9*C20

FC/MC62D

57.0

3.48

4.79

38.0

2.38

4.73

7.70

 

P(C,V)9*D20

FC/MC62D

56.0

3.50

4.68

38.0

2.38

4.73

7.75

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

3.Variable speed furnaces have B.O.D (Blower on Delay) standard.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

14