York YHJD18 THRU 60 Accessories, Typical Installation, Sound Power Ratings, Typical Field Wiring

Models: YHJD18 THRU 60

1 30
Download 30 pages 24.1 Kb
Page 15
Image 15
ACCESSORIES

ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (2SA067*)

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit.

Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below -10°F ambient temperature.

Compressor Blanket - Designed to further reduce the nor- mal operating sound.

Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available.

Thermal Expansion Valve Kit - 1TVM Series TXV kit used to improve system performance.

Outdoor Thermostat (2TD06700124) - Provides additional staging of supplemental electric heat.

TYPICAL INSTALLATION

398612-YTG-B-0608 Room Thermostats - A wide selection of matching thermo- stats is available to provide features required for any installa- tion.

2H/1C, manual changeover electronic non-programmable thermostat.

3H/2C, non-programmable digital thermostat.

3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat.

*For the most current accessory information, refer to the price book or consult factory.

SOUND POWER RATINGS

UNIT MODEL

 

(dBA)*

 

 

 

 

Cooling

 

Heating

018

TBD

 

TBD

024

TBD

 

TBD

030

TBD

 

TBD

036

TBD

 

TBD

042

TBD

 

TBD

048

TBD

 

TBD

060

TBD

 

TBD

* Rated in accordance with ARI 270-95 Standards.

60” OVERHEAD CLEARANCE

6” CLEARANCE AROUND PERIMETER

NOTE:

ALL OUTDOOR WIRING

MUST BE WEATHERPROOF.

MINIMUM 18” SERVICE

ACCESS CLEARANCETHERMOSTAT

ON ONE SIDE

WEATHERPROOF

DISCONNECT

SWITCH

Start Assist Kit (2SA067*) NEC CLASS 1 WIRING

TO FURNACE OR

AIR HANDLER

TERMINAL BLOCK

NEC CLASS 2 WIRING

TO INDOOR COIL

CONTROL

 

ACCESS

SEAL OPENING(S) WITH

PANEL

PERMAGUM OR EQUIVALENT

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-6024 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE

(NEC CLASS 2)

POWER WIRING CONTROL WIRING FACTORY WIRING

CONTACTOR

TERMINALS

GND.

LUGCOIL

CONDENSING UNIT

FURNACE OR AIR HANDLER TERMINAL BLOCK

C Y R G W

* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

*

Y R G W

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

Johnson Controls Unitary Products

15

Page 15
Image 15
York YHJD18 THRU 60 Accessories, Typical Installation, Sound Power Ratings, Typical Field Wiring, Start Assist Kit 2SA067