York YHJD18 THRU 60 warranty YTG-B-0608, Johnson Controls Unitary Products

Models: YHJD18 THRU 60

1 30
Download 30 pages 24.1 Kb
Page 7
Image 7

398612-YTG-B-0608

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

 

 

FURNACE**

 

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

 

 

RATED

NET MBH

SEER1

 

 

W

MODEL

EER

 

(Min.-max.)

 

CFM

 

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450

- 750

 

14,17

FC/MC/PC/UC18

600

18.0

12.9

13.00

11.00

YHJD18S21S1

450

- 750

 

14,17

FC/MC/PC/UC24

600

18.0

12.9

13.00

11.00

450

- 750

 

14,17

FC/MC/PC/UC30

600

18.0

12.9

13.00

11.00

 

 

 

450

- 750

 

14

HC18

600

18.0

12.9

13.00

11.00

 

600 - 1000

 

14,17

FC/MC/PC/UC24

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

14,17

FC/MC/PC/UC30

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

14

FC/MC/PC/UC32

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

17,21

FC/MC/PC/UC35

800

23.0

16.8

13.00

11.00

YHJD24S21S1

600 - 1000

 

14

HC30

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

17

HC36

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

HD24

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

19

MH24S

800

23.0

16.8

13.00

11.00

 

600 - 1000

 

19

MH30S

800

23.0

16.8

13.00

11.00

 

800 - 1200

 

14

FC/MC/PC/UC32

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

17,21

FC/MC/PC/UC35

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

14

FC/MC/PC/UC37

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

17,21

FC/MC/PC/UC43

1000

29.0

21.2

13.00

11.00

YHJD30S21S1

800 - 1200

 

17

HC36

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

21

HC42

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

HD36

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

19

MH24S

1000

29.0

21.2

13.00

11.00

 

800 - 1200

 

19

MH30S

1000

29.0

21.2

13.00

11.00

 

1000

- 1400

 

14

FC/MC/PC/UC37

1200

35.0

25.6

13.00

11.00

 

1000

- 1400

 

17,21

FC/MC/PC/UC43

1200

35.0

25.6

13.00

11.00

 

1000

- 1400

 

21,24

FC/MC/PC/UC48

1200

35.0

25.6

13.00

11.00

YHJD36S21S1

1000

- 1400

 

21,24

FC/MC/PC/UC60

1200

35.0

25.6

13.00

11.00

1000

- 1400

 

21

HC42

1200

35.0

25.6

13.00

11.00

 

 

 

1000

- 1400

 

24

HC60

1200

35.0

25.6

13.00

11.00

 

1000

- 1400

 

HD48

1200

35.0

25.6

13.00

11.00

 

1000

- 1400

 

HD60

1200

35.0

25.6

13.00

11.00

 

1200

- 1600

 

21,24

FC/MC/PC/UC48

1400

40.0

28.8

13.00

11.00

YHJD42S21S1

1200

- 1600

 

21,24

FC/MC/PC/UC60

1400

40.0

28.8

13.00

11.00

1200

- 1600

 

24

HC60

1400

40.0

28.8

13.00

11.00

 

 

 

1200

- 1600

 

HD60

1400

40.0

28.8

13.00

11.00

 

1400

- 1800

 

21,24

FC/MC/PC/UC60

1600

45.0

33.2

13.00

11.00

YHJD48S21S1

1400

- 1800

 

24

FC/MC62

1600

45.0

33.2

13.00

11.00

1400

- 1800

 

24

HC60

1600

45.0

33.2

13.00

11.00

 

 

 

1400

- 1800

 

HD60

1600

45.0

33.2

13.00

11.00

YHJD60S21S1

1600 - 2000

 

24

FC/MC62

1800

55.0

40.0

13.00

11.00

1.Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.

Johnson Controls Unitary Products

7

Page 7
Image 7
York YHJD18 THRU 60 warranty YTG-B-0608, Johnson Controls Unitary Products