Manual background

398612-YTG-B-0608

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

 

COOLING

 

 

MODEL

MODEL

 

W

 

MODEL1

RATED

 

NET MBH

SEER

EER

 

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED

 

 

 

YHJD18S21S1

AV24

 

17

 

565

 

18.0

13.4

14.00

12.00

YHJD24S21S1

AV24

 

17

 

770

 

23.0

17.5

14.00

12.00

YHJD30S21S1

AV36

 

21

 

1015

 

29.0

22.0

14.00

12.00

YHJD36S21S1

AV36

 

21

 

1270

 

35.0

26.2

14.00

12.00

AV/SV48

 

24

 

1270

 

35.0

26.2

14.00

12.00

 

 

 

 

 

AV/SV48

 

24

 

1415

 

41.0

29.4

13.85

11.00

YHJD42S21S1

 

 

 

 

 

 

 

 

 

 

 

AV/SV60

 

24

 

1410

 

41.0

29.4

13.85

11.00

 

F4FV060

 

24

 

1410

 

41.0

29.4

13.85

11.00

 

AV/SV48

 

24

 

1610

 

46.0

33.8

13.25

11.00

YHJD48S21S1

 

 

 

 

 

 

 

 

 

 

 

AV/SV60

 

24

 

1655

 

46.0

33.6

13.25

11.00

 

F4FV060

 

24

 

1655

 

46.0

33.6

13.30

11.00

 

 

 

 

13

SEER HP WITH AHP

/ SHP / F*FP

 

 

 

 

 

 

AHP18

 

17

 

650

 

18.0

12.9

13.00

11.00

YHJD18S21S1

 

 

 

 

 

 

 

 

 

 

 

AHP24

 

17

 

655

 

18.0

13.0

13.00

11.00

 

F4FP024

 

17

 

655

 

18.0

13.0

13.00

11.00

 

AHP24

 

17

 

830

 

23.0

16.9

13.00

11.00

YHJD24S21S1

 

 

 

 

 

 

 

 

 

 

 

AHP30

 

17

 

795

 

23.0

16.8

13.00

11.00

 

F4FP030

 

17

 

795

 

23.0

16.8

13.00

11.00

 

AHP30

 

17

 

1015

 

29.0

21.2

13.00

11.00

YHJD30S21S1

 

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

 

1040

 

29.0

21.2

13.00

11.00

 

F4FP040

 

21

 

1040

 

29.0

21.2

13.00

11.00

 

AHP36

 

21

 

1235

 

35.0

25.6

13.00

11.00

 

AHP42

 

21

 

1255

 

35.0

25.6

13.00

11.00

YHJD36S21S1

AHP/SHP60

 

24

 

1270

 

35.0

26.2

14.00

12.00

F4FP045

 

24

 

1200

 

35.0

25.6

13.00

11.00

 

 

 

 

 

F5FP048

 

24

 

1200

 

35.0

26.2

14.00

12.00

 

F5FP060

 

24

 

1200

 

35.0

26.2

14.00

12.00

 

AHP/SHP48

 

24

 

1400

 

40.0

29.0

13.00

11.00

 

AHP/SHP60

 

24

 

1400

 

41.0

29.4

13.85

11.00

YHJD42S21S1

F4FP045

 

24

 

1400

 

40.0

29.0

13.00

11.00

 

F5FP048

 

24

 

1400

 

41.0

29.4

13.85

11.00

 

F5FP060

 

24

 

1400

 

41.0

29.4

13.85

11.00

 

AHP/SHP48

 

24

 

1600

 

45.0

33.2

13.00

11.00

YHJD48S21S1

AHP/SHP60

 

24

 

1600

 

46.0

33.6

13.30

11.00

 

F5FP060

 

24

 

1600

 

46.0

33.6

13.30

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

6

Johnson Controls Unitary Products

Page 6
Image 6
York YHJD18 THRU 60 warranty YTG-B-0608