HEATING PERFORMANCE DATA

398612-YTG-B-0608

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJD18S21S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHP18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

450

 

 

600

 

 

750

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

19.7

4.21

1.37

21.0

4.24

1.45

22.3

4.29

1.52

60

 

 

 

 

 

 

 

 

 

 

70

18.9

3.79

1.47

20.0

3.99

1.47

21.1

4.19

1.47

 

 

 

 

 

 

 

 

 

 

 

 

80

18.1

3.37

1.57

19.0

3.73

1.49

19.8

4.08

1.42

 

 

 

 

 

 

 

 

 

 

 

 

60

17.4

3.83

1.33

18.3

4.15

1.29

19.1

4.51

1.24

47

 

 

 

 

 

 

 

 

 

 

70

16.2

3.50

1.36

17.0

3.61

1.40

17.8

3.74

1.44

 

 

 

 

 

 

 

 

 

 

 

 

80

14.9

3.16

1.38

15.7

3.06

1.50

16.5

2.96

1.63

 

 

 

 

 

 

 

 

 

 

 

 

60

14.9

3.49

1.25

15.9

3.78

1.23

16.8

4.06

1.21

40

 

 

 

 

 

 

 

 

 

 

70

13.5

3.11

1.28

14.5

3.37

1.26

15.3

3.62

1.24

 

 

 

 

 

 

 

 

 

 

 

 

80

12.1

2.72

1.30

13.0

2.95

1.29

13.8

3.18

1.27

 

 

 

 

 

 

 

 

 

 

 

 

60

13.0

3.28

1.16

13.5

3.46

1.14

14.0

3.69

1.11

30

 

 

 

 

 

 

 

 

 

 

70

11.6

2.88

1.18

12.1

3.06

1.16

12.7

3.27

1.14

 

 

 

 

 

 

 

 

 

 

 

 

80

10.1

2.48

1.19

10.7

2.65

1.18

11.4

2.85

1.17

 

 

 

 

 

 

 

 

 

 

 

 

60

9.7

2.78

1.02

10.1

2.92

1.01

10.4

3.04

1.00

17

 

 

 

 

 

 

 

 

 

 

70

8.4

2.43

1.01

9.0

2.59

1.01

9.5

2.74

1.01

 

 

 

 

 

 

 

 

 

 

 

 

80

7.1

2.08

1.00

7.8

2.26

1.01

8.5

2.44

1.02

 

 

 

 

 

 

 

 

 

 

 

 

60

8.2

2.58

0.93

8.3

2.61

0.93

8.5

2.70

0.92

10

 

 

 

 

 

 

 

 

 

 

70

7.2

2.25

0.93

7.3

2.30

0.93

7.5

2.36

0.93

 

 

 

 

 

 

 

 

 

 

 

 

80

6.1

1.92

0.93

6.3

1.98

0.93

6.5

2.02

0.94

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

FC/MC/PC/UC18

1.00

1.00

1.00

FC/MC/PC/UC24

1.00

1.00

1.00

FC/MC/PC/UC30

1.00

1.00

1.00

HC18

1.00

1.00

1.00

AHP24

1.00

1.00

1.00

AV24

0.96

1.06

0.94

F4FP024

1.00

1.00

1.00

MV12B

FC/MC18B

0.97

1.05

0.95

MA08B

FC/MC18B

1.00

1.00

1.00

MV12B

FC/MC24B

0.97

1.06

0.94

MA08B

FC/MC24B

1.00

1.00

1.00

MV12B

FC/MC30B

0.97

1.06

0.94

MA08B

FC/MC30B

1.00

1.00

1.00

Variable Speed

Coil

MBH

KW

COP

Furnace

 

 

 

 

PV8*A12

FC/MC/PC/UC18A

0.97

1.06

0.94

PV9*A12

FC/MC/PC/UC18A

0.97

1.04

0.96

P(C,V)9*B12

FC/MC/PC/UC18B

0.97

1.06

0.94

PV8*A12

FC/MC/PC/UC24A

0.97

1.06

0.94

PV9*A12

FC/MC/PC/UC24A

0.97

1.04

0.96

P(C,V)9*B12

FC/MC/PC/UC24B

0.97

1.06

0.94

PV8*A12

FC/MC/PC/UC30A

0.97

1.06

0.94

PV9*A12

FC/MC/PC/UC30A

0.97

1.04

0.96

P(C,V)9*B12

FC/MC/PC/UC30B

0.97

1.06

0.94

PV8*A12

HC18

0.97

1.06

0.94

PV9*A12

HC18

0.97

1.04

0.96

Johnson Controls Unitary Products

23

Page 23
Image 23
York YHJD18 THRU 60 Heating Performance Data, Evaporator Coil Model No, Condensing Unit Model No, YHJD18S21S1, AHP18