Manual background

398612-YTG-B-0608

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJD60S21S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

FC/MC62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

 

1600

 

 

1800

 

 

2000

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

 

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

 

60

75.6

 

4.6

4.8

76.1

4.4

5.1

76.6

4.2

5.3

60

 

 

 

 

 

 

 

 

 

 

 

70

72.9

 

5.1

4.2

73.4

4.9

4.4

73.8

4.6

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

80

70.2

 

5.6

3.7

70.6

5.3

3.9

71.0

5.1

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

60

63.8

 

4.3

4.4

64.2

4.1

4.6

64.7

3.9

4.8

47

 

 

 

 

 

 

 

 

 

 

 

70

61.4

 

4.8

3.8

61.8

4.6

4.0

62.2

4.4

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

80

59.0

 

5.3

3.3

59.3

5.0

3.4

59.6

4.8

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

60

53.1

 

4.0

3.9

53.2

4.2

3.7

53.3

4.3

3.6

40

 

 

 

 

 

 

 

 

 

 

 

70

48.9

 

4.4

3.3

49.3

4.6

3.1

49.6

4.8

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

80

44.7

 

4.7

2.7

45.4

5.0

2.7

46.0

5.2

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

60

47.5

 

4.1

3.4

48.8

3.9

3.6

50.2

3.7

3.9

30

 

 

 

 

 

 

 

 

 

 

 

70

46.6

 

4.5

3.0

47.3

4.4

3.2

48.1

4.2

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

80

45.7

 

4.9

2.7

45.8

4.8

2.8

45.9

4.6

2.9

 

 

 

 

 

 

 

 

 

 

 

 

 

60

38.3

 

3.8

2.9

40.1

3.6

3.2

41.9

3.5

3.5

17

 

 

 

 

 

 

 

 

 

 

 

70

36.8

 

4.0

2.7

38.4

4.0

2.8

40.0

3.9

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

80

35.3

 

4.3

2.4

36.7

4.3

2.5

38.1

4.4

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

60

33.1

 

3.4

2.9

34.5

3.5

2.9

36.0

3.6

2.9

10

 

 

 

 

 

 

 

 

 

 

 

70

33.2

 

3.9

2.5

34.0

3.9

2.5

34.7

3.9

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

80

33.4

 

4.4

2.2

33.4

4.3

2.2

33.4

4.3

2.3

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

MV20D

FC/MC62D

1.00

1.01

0.99

MA20D

FC/MC62D

1.00

1.00

1.00

Variable Speed

Coil

 

MBH

KW

COP

Furnace

 

 

 

 

 

 

PV8*C20

 

FC/MC62D

1.00

1.00

1.00

P(C,V)9*C20

 

FC/MC62D

0.98

1.00

1.00

P(C,V)9*D20

 

FC/MC62D

0.96

1.01

0.99

Johnson Controls Unitary Products

29

Page 29
Image 29
York YHJD18 THRU 60 Heating Performance Data, Condensing Unit Model No, YHJD60S21S1, Evaporator Coil Model No, FC/MC62