HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO | YHJD24S21S1 |
|
|
|
|
|
|
| ||
EVAPORATOR COIL MODEL NO | AHP24 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
AIR TEMP. | AIR TEMP. |
|
|
|
| ID CFM |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ENTERING | ENTERING |
| 600 |
|
| 800 |
|
| 1000 |
|
OUTDOOR UNIT | INDOOR COIL |
|
|
|
|
|
|
|
|
|
MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | ||
|
|
|
|
|
|
|
|
|
|
|
| 60 | 25.6 | 4.23 | 1.77 | 26.9 | 4.47 | 1.76 | 28.3 | 4.70 | 1.76 |
60 |
|
|
|
|
|
|
|
|
|
|
70 | 24.4 | 4.09 | 1.75 | 25.8 | 4.41 | 1.71 | 27.3 | 4.75 | 1.68 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 23.2 | 3.95 | 1.72 | 24.7 | 4.35 | 1.66 | 26.2 | 4.79 | 1.60 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 21.8 | 4.46 | 1.43 | 23.1 | 4.90 | 1.38 | 24.3 | 5.35 | 1.33 |
47 |
|
|
|
|
|
|
|
|
|
|
70 | 20.6 | 4.03 | 1.51 | 21.9 | 4.20 | 1.56 | 23.2 | 4.40 | 1.61 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 19.4 | 3.59 | 1.58 | 20.7 | 3.50 | 1.73 | 22.1 | 3.44 | 1.88 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 19.5 | 4.10 | 1.39 | 20.8 | 4.54 | 1.34 | 22.0 | 4.99 | 1.29 |
40 |
|
|
|
|
|
|
|
|
|
|
70 | 18.6 | 3.76 | 1.46 | 19.8 | 4.12 | 1.42 | 21.0 | 4.49 | 1.38 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 17.7 | 3.41 | 1.52 | 18.8 | 3.69 | 1.49 | 19.9 | 3.99 | 1.46 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 17.3 | 3.95 | 1.28 | 18.0 | 4.15 | 1.27 | 18.7 | 4.34 | 1.26 |
30 |
|
|
|
|
|
|
|
|
|
|
70 | 16.0 | 3.54 | 1.33 | 16.8 | 3.73 | 1.33 | 17.6 | 3.93 | 1.32 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 14.7 | 3.12 | 1.38 | 15.6 | 3.31 | 1.38 | 16.5 | 3.52 | 1.37 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 12.8 | 2.71 | 1.38 | 13.5 | 3.16 | 1.25 | 14.1 | 3.68 | 1.12 |
17 |
|
|
|
|
|
|
|
|
|
|
70 | 11.7 | 2.67 | 1.28 | 12.4 | 2.98 | 1.21 | 13.0 | 3.33 | 1.14 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 10.6 | 2.63 | 1.18 | 11.2 | 2.80 | 1.17 | 11.8 | 2.97 | 1.16 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 9.5 | 2.67 | 1.04 | 10.7 | 2.92 | 1.07 | 11.9 | 3.16 | 1.10 |
10 |
|
|
|
|
|
|
|
|
|
|
70 | 9.2 | 2.50 | 1.08 | 10.1 | 2.71 | 1.09 | 10.9 | 2.91 | 1.10 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 8.9 | 2.32 | 1.12 | 9.4 | 2.50 | 1.10 | 9.9 | 2.66 | 1.09 |
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handler | Coil | MBH | KW | COP |
– | FC/MC/PC/UC24 | 1.00 | 1.00 | 1.00 |
– | FC/MC/PC/UC30 | 1.00 | 1.00 | 1.00 |
– | FC/MC/PC/UC32 | 1.00 | 1.00 | 1.00 |
– | FC/MC/PC/UC35 | 1.00 | 1.00 | 1.00 |
– | HC30 | 1.00 | 1.00 | 1.00 |
– | HC36 | 1.00 | 1.00 | 1.00 |
– | HD24 | 1.00 | 1.00 | 1.00 |
– | MH24S | 1.00 | 1.00 | 1.00 |
– | MH30S | 1.00 | 1.00 | 1.00 |
AHP30 | – | 1.00 | 1.00 | 1.00 |
AV24 | – | 0.97 | 1.08 | 0.92 |
FPFP030 | – | 1.00 | 1.00 | 1.00 |
MV12B | FC/MC24B | 0.98 | 1.07 | 0.93 |
MA08B | FC/MC24B | 1.00 | 1.00 | 1.00 |
MV12B | FC/MC30B | 0.98 | 1.07 | 0.93 |
MA08B | FC/MC30B | 1.00 | 1.00 | 1.00 |
MV12B | FC/MC35B | 0.97 | 1.07 | 0.93 |
MA08B | FC/MC35B | 1.00 | 1.00 | 1.00 |
Variable Speed | Coil | MBH | KW | COP | |
Furnace | |||||
|
|
|
| ||
PV8*A12 | FC/MC/PC/UC24A | 0.98 | 1.05 | 0.95 | |
PV9*A12 | FC/MC/PC/UC24A | 0.98 | 1.04 | 0.96 | |
P(C,V)9*B12 | FC/MC/PC/UC24B | 0.98 | 1.05 | 0.95 | |
PV8*A12 | FC/MC/PC/UC30A | 0.98 | 1.05 | 0.95 | |
PV9*A12 | FC/MC/PC/UC30A | 0.98 | 1.05 | 0.95 | |
P(C,V)9*B12 | FC/MC/PC/UC30B | 0.98 | 1.05 | 0.95 | |
PV8*A12 | FC/MC/PC/UC32A | 0.98 | 1.05 | 0.95 | |
PV9*A12 | FC/MC/PC/UC32A | 0.98 | 1.05 | 0.95 | |
P(C,V)9*B12 | FC/MC/PC/UC35B | 0.98 | 1.05 | 0.95 | |
PV8*A12 | HC30 | 0.98 | 1.05 | 0.95 | |
PV9*A12 | HC30 | 0.98 | 1.05 | 0.95 | |
P(C,V)9*B12 | HC36 | 0.98 | 1.05 | 0.95 |
24 | Johnson Controls Unitary Products |