TECHNICAL DATA
Table no.1
TABLE N°1: Conversion to various types of gas |
| APPLIANCE CATEGORY: II2H3+ |
|
| |||||||||
| Burner | Types of Gas | Pressure | Nozzle |
| Rater Capacity |
| Reduced |
| ||||
|
|
|
|
| Diameter |
|
|
|
| Capacity |
|
| |
|
|
|
| Mbar | 1/100 mm. | g/h | l/h | kw | kcal/h | kw | Kcal/h | 1/100 mm. |
|
|
| Natural | G20 | 20 | 72 | - | 95 | 1 | 860 | 0,48 | 413 | 34 |
|
| Auxiliary | Butane | G30 | 28 | 50 | 73 | - | 1 | 860 | 0,48 | 413 | 34 |
|
|
| Propane G31 | 37 | 50 | 71 | - | 1 | 860 | 0,48 | 413 | 34 |
| |
| Semi- | Natural | G20 | 20 | 97 | - | 167 | 1,75 | 1505 | 0,6 | 516 | 36 |
|
| rapid | Butane | G30 | 28 | 65 | 127 | - | 1,75 | 1505 | 0,6 | 516 | 36 |
|
|
| Propane G31 | 37 | 66 | 125 | - | 1,75 | 1505 | 0,6 | 516 | 36 |
| |
|
| Natural | G20 | 20 | 115 | - | 286 | 3 | 2580 | 1,05 | 903 | 52 |
|
| Rapid | Butane | G30 | 28 | 85 | 218 | - | 3 | 2580 | 1,05 | 903 | 52 |
|
|
| Propane G31 | 37 | 85 | 214 | - | 3 | 2580 | 1,05 | 903 | 52 |
| |
| Double | Natural | G20 | 20 | 135 | - | 334 | 3,5 | 3010 | 1,8 | 1548 | 65 |
|
| Ring | Butane | G30 | 28 | 95 | 254 | - | 3,5 | 3010 | 1,8 | 1548 | 65 |
|
|
| Propane G31 | 37 | 95 | 250 | - | 3,5 | 3010 | 1,8 | 1548 | 65 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INSTALLATION
Positioning
Remove all the packaging and install the cooker in a dry, ventilated room not near curtains, paper, alcohol, petrol etc.
The appliance must be set on a heatproof, level floor.
This appliance is approved to class “Y”
Any walls of the adjacent kitchen furniture and the wall behind the cooker must be made with heat resistant material that can withstand a minimum temperature rise of 65K.
Any overhanging cabinetry installed above the work surface must be located at a distance of no less than 700mm.
Fig. 1
Fig. 2
25