Electrical Connection

electrolux 39

Electrical Connection

The oven must be installed according to the instructions supplied.

This oven must be installed by qualified personnel to the relevant British Standards.

Theovenisdesignedtobeconnectedto230V(50 Hz) electricitysupply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earthterminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The oven must be installed according to the instructions supplied.THIS OVEN MUST BE EARTHED

Thecableusedtoconnecttheoventotheelectrical supply must comply to the specifications given below.

It is necessary that you install a double pole switch betweentheovenandtheelectricitysupply(mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

the yellow and green earth cable should be 2-3 cm longer than the other cables.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load and that the power supply is properly earthed.

The manufacturer declines any responsibility should these safety measures not be carried out.

Connection

 

Min. size

Cable / flex

 

Fuse

via

 

Cable/flex

type

 

 

 

 

 

 

 

 

 

13 A socket

 

2.5 mm2

3 core

 

13 A min.

outlet

 

 

 

butyl

 

 

 

 

 

 

 

insulated

 

 

 

13 A spur box

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

 

2.5 mm2

PVC/PVC

 

15 A min.

Control

 

 

 

twin and

 

Circuit

 

 

 

earth

 

20 Amax.

For Europe use only

 

 

 

 

 

 

 

 

 

 

 

 

Min. size Cable/

 

Cable / flex type

Fuse

 

flex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 mm2

 

H07 RN-F, H05 RN-F,

15 A

 

 

 

 

H05 RR-F, H05 VV-F,

 

 

 

 

 

 

H05 V2V2-F (T90),

 

 

 

 

 

 

H05 BB-F

 

 

 

 

 

 

 

 

 

 

 

 

39