UC Series Charger/Conditioner

IMPORTANT: Never charge or condition battery packs while attempting to run the printer.

Description

The UC series of Charger/Conditioners is designed to charge and condition individual battery packs used on the MP, RP, Encore and Cameo series of portable printers. Battery packs may be charged off-unit or while connected to the printer. Typical charge time is 60 to 90 minutes.

Charging Battery Packs

Plug the A.C. line cord into an A.C. receptacle, then plug the charge cable into the battery pack’s charger jack. The “Power” light will come on, followed by the “Charge” light.

When the Battery Pack has been fully charged, the “Charge OK” indicator will light.

Conditioning Battery Packs

NiCad type battery packs used on a daily basis should be “conditioned” once a week to insure they keep their maximum charge life. This is especially important with batteries that are usually recharged with the Trickle Charger.

1.Connect the Charger to an A.C. power source.

2.Plug the charger into the

battery pack’s charger jack. Wait 5 seconds.

3. Press and hold

the “Condition”

“Power”Light

button for

“Charge”Light

1 second

“ChargeOK”Light

until the

 

red

 

“Condi-

 

tioning”

 

indicator

 

lights .

“Condition”Button

 

 

“Conditioning”Light

UMAN-Charge18