UC Series Charger/Conditioner
IMPORTANT: Never charge or condition battery packs while attempting to run the printer.
Description
The UC series of Charger/Conditioners is designed to charge and condition individual battery packs used on the MP, RP, Encore and Cameo series of portable printers. Battery packs may be charged
Charging Battery Packs
Plug the A.C. line cord into an A.C. receptacle, then plug the charge cable into the battery pack’s charger jack. The “Power” light will come on, followed by the “Charge” light.
When the Battery Pack has been fully charged, the “Charge OK” indicator will light.
Conditioning Battery Packs
NiCad type battery packs used on a daily basis should be “conditioned” once a week to insure they keep their maximum charge life. This is especially important with batteries that are usually recharged with the Trickle Charger.
1.Connect the Charger to an A.C. power source.
2.Plug the charger into the
battery pack’s charger jack. Wait 5 seconds.
3. Press and hold
the “Condition” | “Power”Light | |
button for | ||
“Charge”Light | ||
1 second | “ChargeOK”Light | |
until the |
| |
red |
| |
“Condi- |
| |
tioning” |
| |
indicator |
| |
lights . | “Condition”Button | |
| ||