The condition cycle for a fully charged battery is approximately 90 minutes.

If the “Charge OK” indicator blinks, disconnect the battery pack and wait until all the lights except the “Power “ light go out. Reconnect the battery and repeat step 3.

UC Series Charger Models

Base Part Number*

Used on

Charge Method

CC12708-1x

MP5020/22

Cable

CC12708-2x

MP5030

Cable

 

 

 

CC12708-3x

MP5044

Cable

CC12708-5x

RP3

Cable to Printer

 

 

 

CC12891-1x

RP3

Battery Drop-In

CC12708-7x

Encore 2,3, Cameo

Cable

CC12708-8x

Encore 4

Cable

* Last digit in part number Indicates model:

-X0= North American model

-X1= U.K. model

-X2= Continental European model

-X3= Australian model

These models use NiMH type battery packs. Conditioning is not necessary once batteries have been cycled several times. A NiMH battery is” cycled” by fully charging it, then fully discharging it through normal use. The “Condition” cycle on UC series chargers can also be used for this purpose.