Problem

Diagnosis

Solution

 

 

Confirm that the tags meet

 

Tags have metal/aluminum

requirements (i.e. no metal/

 

in them.

aluminum in them)

NO TAG Error Message

 

Reload with proper tags.

(Continued)

 

 

ZPL II giving insufficient

Increase the number of retries in

 

 

amount of retries.

the ZPL II commands.

 

 

 

 

Tag is bad.

Load new tags.

 

 

 

 

 

Retry printing label.

 

 

 

 

An attempt was made to

Cycle power and try printing

 

label again.

PK TIMEOUT Error Message

communicate to the internal

 

Verify internal cabling

 

hardware, but timed out.

 

 

connections

 

 

 

 

 

Call service technician.

 

 

 

Other Error Messages

Problem not correctable by

Call service technician.

User.

 

 

 

 

 