110Hardware Troubleshooting Troubleshooting the 10/100 PS

Troubleshooting the 10/100 PS

Defaulting the 10/100 PS

To default the 10/100 Internal PS to factory settings using the control panel, complete these steps:

1.From the control panel, press Setup/Exit two times.

2.Press Plus (+ key) five times.

The control panel will read DEFAULT NET.

3.Press Setup/Exit to save the change.

4.After the printer defaults all settings, the control panel will show PRINTER READY.

10/100 Internal PS Network Status/Activity Indicator

A single LED containing a red element and a green element. By turning on and off different combinations of these two LED elements indicate Ethernet links, activity, and speed.

LED State

 

 

Description

 

 

Off

No Ethernet link detected

 

 

 

Green

100

Mbps link detected

 

 

 

Green, flickering off and on

100

Mbps link detected and Ethernet activity detected

 

 

 

Amber

10

Mbps link detected

 

 

 

Amber, flickering off and on

10

Mbps link detected and Ethernet activity detected

 

 

 

 

ZebraNet View Utility Discovery or Configuration Problems

If you are having problems using the ZebraNet View utility to discover or configure the unit, check the following:

Verify there is not a router between the workstation running ZebraNet View and the 10/100 Internal PS. Because the 10/100 Internal PS does not have an IP address, TCP/IP communication cannot be started across a router. Run ZebraNet View on the same subnet as the 10/100 Internal PS.

Verify that the LED on the 10/100 Internal PS is active. Consult the chart above for details.