8. Operation

The spray range is changed by shifting the bell posi- tion after loosening the lock ring.

(A)Pulled out position: Long distance, narrow angle spray

(B)Pushed In position: Short distance, wide angle spray

3.Start the engine and carry the unit on your back.

4.While holding the control handle in your right hand, move the throttle lever upward and turn the interme- diate valve to the open position.

5.After spraying work has finished, close the intermedi- ate valve and stop the engine.

WARNING

Before the solution spraying work, supply water into the tank and operate the mister to make sure that there is any leakage or any mechanical fail- ure.

Repair it if there is any leakage or failure before the solution spraying work.

Discharge rate

Valve travel

(lit/min.)

1

1

2

2

3

3

4

4

 

Max. Longitudinal coverage

 

 

Horizontal direction :

12 m

Vertical direction :

12 m

GB-14