ZyXEL Communications Comet 336P user manual Status Registers & Result Codes, Register Definitions

Models: Comet 336P

1 30
Download 30 pages 37.36 Kb
Page 27
Image 27

5 Status Registers & Result Codes

In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an asterisk. Some bits are reserved for factory use and should not be changed.

S-Registers "ATSn=x"

Command

Function & Description

Range

Ref.

S0

Number of rings before Auto Answer. 0 value disables auto-

0-255 (0)

ATA

 

answer.

 

 

S1

Ring counter.

0-255 (0)

 

S2

ASCII value of Escape character.

0-255 (43)

 

S3

ASCII value of Carriage Return character.

0-127(13)

 

S4

ASCII value of Line Feeder character.

0-127 (10)

 

S5

ASCII value of Backspace character.

0-32 (8)

 

S6

Waiting time before blind dialing. (seconds)

2-255 (2)

 

S7

Wait foe carrier after dial. (seconds)

1-255 (50)

 

S8

Pause time for comma. (seconds)

1-255 (50)

 

S9

Carrier detect response time. (1/10 seconds)

1-255 (6)

 

S10

Delay between loss of carrier and hang-up. (1/10 seconds)

1-255 (14)

 

S11

DTMF (Touch tone) tone duration. (1/10 seconds)

50-255 (95)

 

S12

Escape guard time. (1/50 seconds)

0-255 (50)

 

S18

Test timer. (seconds)

0-255 (0)

 

S25

Delay to DTR. (1 second for sync mode 1; 0.01 for otherwise)

0-255 (5)

 

S26

RTS to CTS delay interval. (0.01 seconds)

0-255 (1)

 

S30

Inactivity disconnect timer. (0.1 seconds)

0-255 (0)

 

S-Register Definitions

S0 - Number of Rings to Auto-Answer

Sets the number of the rings required before the modem automatically answers a call. Setting this register to zero disables auto-answer mode.

S1 - Ring Counter

S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an eight second interval.

S2 - Escape Character

S2 holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII '+'. A value over 127 disables the escape process, i.e., no escape character will be recognized.

S3 - Carriage Return Character

Sets the command line and result code terminator character. Pertains to asynchronous operation only.

Status Registers & Result Codes 21

Page 27
Image 27
ZyXEL Communications Comet 336P user manual Status Registers & Result Codes, Register Definitions, Registers ATSn=x