Remington BV12200A, BV1220DAT Blower/vac operation, Extension Cords, Connecting Extension Cord

Page 11

Remington electric blower/vac 

4 blower/vac operation

IMPORTANT:This blower/vac is for house- hold use only.

WARNING: Read and under- stand this owner’s manual before operating blower/vac. Make cer- tain you read and understand all Safety Warnings on pages 1 and 2 of this manual. Improper use of this blower/vac can result in severe injury or death from fire, electric shock, or body contact with moving parts.

WARNING: To reduce the risk of electric shock, use only with an extension cord intended for outdooruse,suchasSW-A,SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A, or SJTOW-A.

Extension Cords

Make sure your extension cord is in good condition.Inspect extension cords periodi- cally and replace if damaged. When using an extension cord,be sure to use one heavy enough to carry the current your blower/vac will draw. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating.

Thetablebelowshowsthecorrectsizeexten- sion cord to use depending on cord length andnameplateampererating.Ifindoubt,use the next larger gauge cord. The smaller the gauge number,the larger the cord.To reduce the risk of disconnection of blower/vac from the extension cord during operation,use the cord hitch described in this manual.

Cord Length

AWG Cord Size

25 feet

16 AWG

50 feet

16 AWG

100 feet

14 AWG

150 feet

12 AWG

To reduce the risk of electric shock, this blower/vac has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. The blower/vac’s plug will fit into a polarized extension cord only one way. If the plug does not fit fully into the extension cord, reverse the plug. If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord will require the use of a polarized wall outlet. This plug will fit into the polarized wall outlet only one way. If the plug does not fit fully into the wall outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician to install the proper wall outlet. Do not change the blower/vac plug, extension cord receptacle, or exten- sion cord plug in any way.

Inspect cord often. Replace if damaged.

Connecting Extension Cord

WARNING: Fully seat the ex- tension cord on the inlet plug of blower/vac. Failure to do so could lead to overheating of blower/ vac. This could cause a fire that results in personal injury to you or others.

The blower/vac has a built-in extension cord retainer. This cord hitch prevents ac- cidental disconnection of the power cord during use. The cord hitch is molded into the lower rear of the blower/vac housing.

1.Plug extension cord into the inlet plug of appliance (see Figure 4-1).

2.Create a loop in the extension cord and insert the loop through the cord slot of the blower/vac housing (see Figure 4-2).

3.Pull the loop tight around the molded cord hitch (see Figure 4-3).

Figure 4-1: Plugging extension cord into inlet plug

Figure 4-2: Inserting extension cord loop through cord slot

Figure 4-3: Pull extension cord loop tight around molded cord hitch

120133

Image 11
Contents Electric BLOWER/VAC 120133 Table of contents Welcome Blower/vac Important safety informationMaintenance and Storage of Blower/vac BV12200A BV12200AT SpecificationsProduct identification Assembling Blower Blower/vac assemblySliding vacuum tube adapter into place Converting from Blower to VacuumConverting from Blower to Vacuum Cord Length AWG Cord Size Connecting Extension CordBlower/vac operation Extension CordsBlower Operation Operating Blower/VacFrom Blower to Vacuum. Follow the steps Vacuum OperationRemoving Clogged Debris from the Impeller Emptying the Vacuum BagServicing Double-Insulated Appliances Blower/vac maintenanceCleaning Maintenance Technical Service TroubleshootingDescription Number Replacement partsReplacement Parts PartRemington brand Electric Blower/Vac Warranty informationCon doble aislamiento SOPLADORA/ASPIRADORA Eléctrica120133 Tabla de contenidos Modelo Número Fecha de Compra Lugar de Compra BienvenidoImportante información sobre la seguridad Guarde Estas Instrucciones Especificaciones Identificación del productoEnsamble de la sopladora Ensamble de la sopladora/aspiradoraConversión de sopladora en aspiradora Conversión de sopladora en aspiradora, continuación Largo del Operación de la sopladora/aspiradoraCordones de extensión Conexión del cordón de extensión Operación como sopladora Operación de la sopla- dora/aspiradoraFigura 4-9 Recolección de desechos con la aspiradora Operación como aspiradoraVaciado de la bolsa de la aspiradora Prestación de servicio a herramientas con doble aislamiento Limpieza y mantenimientoServicio Técnico Análisis de averíasArtículo Descripción Número Piezas de repuestoPiezas de repuesto Nuevos Productos Información sobre la garantía120133 Double Isolation Souffleur / Aspirateur Électrique120133 Identification du produit Table des matièresNuméro de modèle Date d’achat Endroit d’achat BienvenueImportants renseignements de sécurité Conservez CES Directives Fiche technique Identification du produitAssemblage du souffleur Assemblage du souffleur / aspirateurFaites glisser l’adaptateur du tube d’aspirateur en place Conversion du souffleur en aspirateurConversion du souffleur en aspirateur, suite Longueur Calibre AWG Utilisation du souffleur / aspirateurRallonges électriques Branchement de la rallonge électrique Utilisation du souffleur Utilisation du souffleur / aspirateurRamassage des débris au moyen de l’aspirateur Utilisation de l’aspirateurRetrait des débris qui engor- gent le rotor Vidange du sac d’aspirateurEntretien des outils à double isolation Entretien du souffleur / aspirateurEntretien et nettoyage Dépannage Service techniqueArticle Description No de pièce Pièces de rechangePièces de rechange Produits Neufs Renseignements sur la garantie120133 120133 120133-01 Rev. a 01/07