VOYAGEUR GRAND Wood Insert
R
G. Tube Channel Assembly Replacement
Removing Tube Channel Assembly
1.Remove the 3 right side bricks.
2.Remove the baffle protection channel by bending back the tabs using needle nose pliers located at the right and left side of the protection cover. Lift the cover up slightly and pull toward the front and out of the firebox. Figure 24.1.
3.Locate the 2 channel nuts and two bolts inside of chamber and remove using a 7/16 socket wrench. Figure 24.2.
NOTE:Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them.
4.Slide the tube channel assembly all the way to left until it is off the threads. Drop the right side down, then slide the assembly back to right. Figure 24.3.
5.The ceramic blanket and both baffle boards can be removed at the same time you remove the tube channel assembly.
6.When the tube channel assembly is free of the left side sup- port, rotate clockwise and pull assembly, blanket and baffles out through the front opening.
7.
Bend Back Tabs
Baffle Protection
Channel
Figure 24.1
Use 7/16 Socket Wrench
and Remove Channel Nuts
Figure 24.2
Tube | 2 Tube Channel Nuts | |
Channel | ||
| ||
Assembly |
| |
| Ceramic Blanket | |
| 2 Baffle Boards | |
| Baffle | |
| Protection Channel |
Figure 24.3
Page 24 | September 25, 2012 |