SYSTEM DESCRIPTION

3.5Paging Stations

The DPC 4000 Series paging consoles are mainly meant for transmitting voice messages and calls but also to manually control the PROANNOUNCE system. Available paging station functions are: line/group selection, voice messages, program assignment, launching gong and alarm signals, and reproduction of voice message memory announcements. Additionally, special commands include volume control, monitor selection, preset switching, lighting control, function status indication, etc. Thus, it is possible to configure the paging consoles to serve as operation panels for general control purposes.

If a voice call is being launched into a speaker line that is already busy with other audio transmissions, the caller gets a busy-sign, i. e. the BUSY-LED blinks. In case the calling terminal has a higher priority it will interrupt any messages from other paging stations or audio signals with lower priority levels. Interruption does not take place uncontrolled anymore. Before actually interrupting a transmission, the blinking LED indicates that a line or group is busy when selecting a destination, leaving the choice to the operator, whether he/she immediately wants to interrupt or wait upon the conclusion of the momentary reproduced program.

3.6Control Inputs And Outputs

By using the control inputs, it is possible to link the PROANNOUNCE system to fire alert systems, burglary alert systems, or to a central operating desk. It is also possible to connect external switches, breakers, rotary controls or rotary encoders, respectively to query control outputs of external units (power supplies, power amplifiers, …).

The control outputs allow switching external devices ON or OFF, trigger signals and events, switch monitor sources, remote control doors, gates or shutters, generate analog signals for the control of multimedia systems, etc.

A total of 130 control inputs for logic levels, 128 control inputs for analog levels, 16 inputs for rotary encoders, 127 logic-control outputs, and 128 analog-control outputs are usable.

3.7Clock / Calendar

The PROANNOUNCE manager DPM 4000 has an integrated quartz-controlled real-time clock which can be set for radio-controlled DCF 77 operation using the optional antenna (DCF 77 tuner NRS 90193). The system clock automatically recognizes leap years and, if in DCF 77 mode, automatically switches between daylight saving time and standard time.

The system clock provides the possibility to control up to 40 external slave clocks. For this purpose, the DPM 4000 employs a special, short-circuit-proof output for pole changing impulses. Slave clocks are automatically re- synchronized whenever a time difference to the system clock is detected; like for instance in cases of power outage or when time values were entered manually.

It is possible to activate pre-set functions like break-gong signals, background music, remotely controlled gates, switch lights ON/OFF, etc. when using system clock and calendar function together All the functions mentioned before can be programmed for specific days; but also hourly, daily, weekly, monthly, and yearly activation is possible. Up to 500 time- controlled events can be programmed.

3.8Monitoring

The PROANNOUNCE manager DPM 4000 embodies a monitor amplifier with headphones/speaker output. The integrated logic-switching circuit provides the opportunity to listen to the signals of any internal input and output. Assigning external sound sources to the monitor bus is possible as well. This additionally allows monitoring amplifier outputs or pre-listen to the contents of external voice message memories and other audio devices.

The remote control’s wiring already includes all the cabling necessary for the pre-/post-listen feature when using remote-controlled amplifiers.

When using the DCS 420 PROANNOUNCE MONITOR MANAGER, easy programming and operating is available. See also chapter 5.4.7

PROANNOUNCE System User Handbook 1.1

3-3

Image 11
Contents Page Page Preamble IntroductionOperation Instructions Safety InstructionsProannounce System User Handbook Operation Instructions Central Unit DPM DCS 400 Control System DPA 4000 Power AmplifierDPP 4000 Power Supply Units DPC 4000 Paging StationsOperation Location Excluded From WarrantyGeneral Overview System DescriptionAudio Routing Volume And Tone Controls / DelaysSignal Generators / Voice Message Memory Monitoring Paging StationsControl Inputs And Outputs Clock / CalendarInterfaces Safety StandardsMacros Software Installation Installation And Program Start System SpecificationsStarting Proannounce Designer Uninstalling Proannounce DesignerDescription Of Individual Devices Digital Proannounce Manager DPM FeaturesDPM Front View DC Input 24V == Signal Pins Description +24V ==Rear View RS-232 PC Interface Remote Control socketAudio Input Module Slots Monitor Output socketExtension slot Control Module Slot Slots for Audio Output ModulesMonitor input SpecificationsSupply voltage 5 2-Channel Paging Station Module NRS SpecificationsBlock Diagram Pin-Assignment Of DPC 4000 Connectors And The Extension CordRetrofitting Input Transformers 6 MIC/LINE + 2 AUX Input Module NRS SpecificationsInternal Settings Pin-Assignment Of XLRF-Type ConnectorsBlock diagram Retrofitting Input Transformers DPM MLI 7 2-Channel MIC/LINE Input Module NRSOpen 24 dBu Retrofitting Input Transformers DPM AUX 8 2-Channel AUX Input Module NRSBlock diagram 2-channel AUX input module 22 MIC/LINE + paging station module NRS 9 MIC/LINE + Paging Station Module NRSAudio 24V/GND Pin-Assignment Of RJ-45 Socket And Extension CordBlock diagram MIC/LINE + paging station module Retrofitting Input Transformers DPM OUT 10 2-Channel Line Output Module NRSSetting Output Levels Via Jumpers Pin-Assignment Of XLRM-Type ConnectorsRetrofitting Output Transformers 31 8 I/O control module 11 8 I/O Control Module NRSSlave clocks Pin-Assignment Of RJ-45 ConnectorsInternal Message Recorder Flash Memory for Voice Recording/Playback NRSProannounce DPC 4000 Paging Consoles System Overview Table of all functions Paging Console FunctionsALL key and LED Cancel keyControl Panel Of The DPC Selection Keys and LED’sOn key and LED Alarm key and IndicatorText key and LED Talk key and BUSY-LEDLAN socket ConnectionsMicrophone DisplayTested printer models are HP LaserJet 6P Key-LabelingCollective Call Gong Chime SignalOperation Selective CallText Message General AlarmSelective Alarm Canceling SignalsSpecial Functions System on / OFFProgram Assignment Address Paging Console Configuration In Setup ModeLCD-Contrast Pre-Gong SignalBuzzer CompressorLED IndicationsCombination PrioritiesDPC 4350 Paging Station Extension Factory Presets DPC SpecificationsOptional Alarm Key NRS Optionally Available AccessoriesChange from Switch to Pushbutton Optional Key-lock Switch NRS Input / Output Transformer NRS Optional Monitor Loudspeaker NRS External MIC / Line Input EXT socket Connecting a PTT-MicrophoneConnecting External Audio Signal Sources Single Paging Station + Extension On a Single DPM-Line Cable LengthSingle Paging Station On a Single DPM-Line DPA 4000 Proannounce Power Amplifier Characteristics Instructions For Using Remote-Power Amps Control Four-Channel Power Amplifier DPAControl DCS 400 Control System Characteristics Operating current at 24 FeaturesOperating voltage Operating currentDCS Dimensions of the DCS 401 moduleDCS 408 Relay Module 100 DCS Dimensions of the DCS 408 moduleOperating current, all relays pulled, at 24 Contact current, maximum Operating temperature rangeMaximally 12 DCS 408 / DCS 409 modules can be Operating current, all inputs at Power source 24V CN6 Maximum output currentOperating current, all inputs open +24VOUT -24VOUT Output DCS 416 analog I/O module DCS 416 Analog Input / Output ModuleDAC Weight Audio input Input voltage 0 dB LED Specifications Operating voltageOperating temperature range Dimensions W x H x D 19 2HU+ 24 Operation keys Function+10 NRS 90240 Rotary Encoder Page Cabling Proannounce Hardware Configuration 1 DCSBefore initial operation Voltage SupplyDCS 401 Addresses DMM DPM DMM 4650 InterconnectionNRS 90226 Adapter Printed Board Assembly

DPM 4000 specifications

The Dynacord DPM 4000 is a high-performance digital power mixer designed to cater to the needs of live sound engineers, musicians, and audio professionals. It offers an extensive range of features and cutting-edge technologies, making it the go-to choice for both small venues and large-scale productions.

One of the standout features of the DPM 4000 is its intuitive user interface. The large, bright LCD screen provides clear visibility of all essential parameters, allowing for quick adjustments even in low-light conditions. The mixer includes a comprehensive built-in effects processor, featuring multiple reverb, delay, and modulation effects that can be applied to individual channels or the overall mix. This capability provides sound engineers with the tools they need to enhance their audio output effortlessly.

The DPM 4000 is equipped with a robust 16-channel configuration, providing ample input options for microphones, instruments, and other audio sources. Each channel is fully equipped with EQ controls, gain adjustments, and auxiliary sends, allowing for precise shaping of the sound. The mixer also supports multi-track recording via USB, making it easy for users to capture performances directly to a computer.

In terms of connectivity, the Dynacord DPM 4000 excels with multiple options including XLR, TRS, and RCA inputs. Its flexible routing capabilities enable sound engineers to customize their signal flow, enhancing both versatility and convenience during live performances. Additionally, the mixer supports remote control through dedicated software applications, enabling users to manage settings from a distance, a significant advantage for live sound applications.

The DPM 4000 features advanced thermal management technology, ensuring the unit remains cool during long operational periods. This is critical for maintaining optimal performance and longevity. The built-in power amplifier delivers impressive wattage, suitable for driving various loudspeaker systems while maintaining sound clarity and fidelity.

Another notable characteristic is its rugged construction, built to withstand the rigors of touring and frequent usage. The design ensures durability in diverse environmental conditions while maintaining aesthetic appeal.

In summary, the Dynacord DPM 4000 is a versatile and powerful digital power mixer, offering a blend of user-friendly features, comprehensive control, and robust performance. Whether used in a live sound setting or for recorded sessions, it stands out as an exceptional tool for audio professionals committed to delivering high-quality sound.