5.3.2 Instructions For Using Remote-Power Amps:

1.Each power amplifier has to be set to the exact address as it is specified in the PROANNOUNCE Designer software (A=low value part, B=high value part). Address setting is performed using hexadecimal code.

2.An RS-485 connection needs to be established between the DPM 4000 (remote socket) and maximally eight DCS 401, and maximally 64 amplifiers (DPA 4411 counts as a single unit). The RS-485 bus may not exceed a maximum length of 1,000m and must follow a line-structure with stub cables being as short as possible. When including more than 30 amplifiers, both ends of the bus have to be terminated with 120 ohms resistors. This bus is also used for monitor signal transmission.

3.Connect the amplifier(s) to an operation voltage source.

4.Perform a Netscan procedure via the PROANNOUNCE Designer software. In ‘normal’ operation the status- LED’s on the rear panel of the amplifiers have to light periodically, depending on the number of participants on the bus (communication with the DPM 4000).

5.Within the communication window of the PROANNOUNCE Designer software checking which addresses are registered as participants is possible using the command “/AMP/AVLBL ?”.

6.Once a participant on the bus had been disconnected from the DPM 4000 for a short term (e.g. because the RS-485 line had temporarily been disconnected), it is included again in the query sequence after 10 sec.

5.3.3Remote Module for Single-Channel-Amplifiers DPA 4120 and DPA 4140 NRS 90222

This single-channel input module provides DPA 4120 or DPA 4140 power amplifiers with remote functionality.

(For detailed information on DPA 4120 and DPA 4140 power amplifiers, please refer to the owner’s manual 355768.)

The module allows connecting balanced XLR-input and XLR-thru lines as well as connection to the remote control bus of the DPM 4000 (RS-485). Prior to connecting the amplifier to the operating voltage, the unit’s address has to be set using the switches “A” and “B” (A=low value part)

PROANNOUNCE System User Handbook 1.1

5-51

Image 65
Contents Page Page Preamble IntroductionOperation Instructions Safety InstructionsProannounce System User Handbook Operation Instructions Central Unit DPM DPP 4000 Power Supply Units DPA 4000 Power AmplifierDPC 4000 Paging Stations DCS 400 Control SystemOperation Location Excluded From WarrantyGeneral Overview System DescriptionAudio Routing Volume And Tone Controls / DelaysSignal Generators / Voice Message Memory Control Inputs And Outputs Paging StationsClock / Calendar MonitoringInterfaces Safety StandardsMacros Software Installation Installation And Program Start System SpecificationsStarting Proannounce Designer Uninstalling Proannounce DesignerDescription Of Individual Devices Digital Proannounce Manager DPM FeaturesDPM Front View DC Input 24V == Signal Pins Description +24V ==Rear View RS-232 PC Interface Remote Control socketExtension slot Control Module Slot Monitor Output socketSlots for Audio Output Modules Audio Input Module SlotsMonitor input SpecificationsSupply voltage 5 2-Channel Paging Station Module NRS SpecificationsBlock Diagram Pin-Assignment Of DPC 4000 Connectors And The Extension CordRetrofitting Input Transformers 6 MIC/LINE + 2 AUX Input Module NRS SpecificationsInternal Settings Pin-Assignment Of XLRF-Type ConnectorsBlock diagram Retrofitting Input Transformers DPM MLI 7 2-Channel MIC/LINE Input Module NRSOpen 24 dBu Retrofitting Input Transformers DPM AUX 8 2-Channel AUX Input Module NRSBlock diagram 2-channel AUX input module 22 MIC/LINE + paging station module NRS 9 MIC/LINE + Paging Station Module NRSAudio 24V/GND Pin-Assignment Of RJ-45 Socket And Extension CordBlock diagram MIC/LINE + paging station module Retrofitting Input Transformers DPM OUT 10 2-Channel Line Output Module NRSSetting Output Levels Via Jumpers Pin-Assignment Of XLRM-Type ConnectorsRetrofitting Output Transformers 31 8 I/O control module 11 8 I/O Control Module NRSSlave clocks Pin-Assignment Of RJ-45 ConnectorsInternal Message Recorder Flash Memory for Voice Recording/Playback NRSProannounce DPC 4000 Paging Consoles System Overview Table of all functions Paging Console FunctionsControl Panel Of The DPC Cancel keySelection Keys and LED’s ALL key and LEDText key and LED Alarm key and IndicatorTalk key and BUSY-LED On key and LEDMicrophone ConnectionsDisplay LAN socketTested printer models are HP LaserJet 6P Key-LabelingOperation Gong Chime SignalSelective Call Collective CallSelective Alarm General AlarmCanceling Signals Text MessageSpecial Functions System on / OFFProgram Assignment Address Paging Console Configuration In Setup ModeBuzzer Pre-Gong SignalCompressor LCD-ContrastLED IndicationsCombination PrioritiesDPC 4350 Paging Station Extension Factory Presets DPC SpecificationsOptional Alarm Key NRS Optionally Available AccessoriesChange from Switch to Pushbutton Optional Key-lock Switch NRS Input / Output Transformer NRS Optional Monitor Loudspeaker NRS External MIC / Line Input EXT socket Connecting a PTT-MicrophoneConnecting External Audio Signal Sources Single Paging Station + Extension On a Single DPM-Line Cable LengthSingle Paging Station On a Single DPM-Line DPA 4000 Proannounce Power Amplifier Characteristics Instructions For Using Remote-Power Amps Control Four-Channel Power Amplifier DPAControl DCS 400 Control System Characteristics Operating voltage FeaturesOperating current Operating current at 24DCS Dimensions of the DCS 401 moduleDCS 408 Relay Module 100 DCS Dimensions of the DCS 408 moduleOperating current, all relays pulled, at 24 Contact current, maximum Operating temperature rangeMaximally 12 DCS 408 / DCS 409 modules can be Operating current, all inputs at Power source 24V CN6 Maximum output currentOperating current, all inputs open +24VOUT -24VOUT Output DCS 416 analog I/O module DCS 416 Analog Input / Output ModuleDAC Operating temperature range Specifications Operating voltageDimensions W x H x D 19 2HU Weight Audio input Input voltage 0 dB LED+ 24 Operation keys Function+10 NRS 90240 Rotary Encoder Page Cabling Proannounce Hardware Configuration 1 DCSBefore initial operation Voltage SupplyDCS 401 Addresses DMM DPM DMM 4650 InterconnectionNRS 90226 Adapter Printed Board Assembly

DPM 4000 specifications

The Dynacord DPM 4000 is a high-performance digital power mixer designed to cater to the needs of live sound engineers, musicians, and audio professionals. It offers an extensive range of features and cutting-edge technologies, making it the go-to choice for both small venues and large-scale productions.

One of the standout features of the DPM 4000 is its intuitive user interface. The large, bright LCD screen provides clear visibility of all essential parameters, allowing for quick adjustments even in low-light conditions. The mixer includes a comprehensive built-in effects processor, featuring multiple reverb, delay, and modulation effects that can be applied to individual channels or the overall mix. This capability provides sound engineers with the tools they need to enhance their audio output effortlessly.

The DPM 4000 is equipped with a robust 16-channel configuration, providing ample input options for microphones, instruments, and other audio sources. Each channel is fully equipped with EQ controls, gain adjustments, and auxiliary sends, allowing for precise shaping of the sound. The mixer also supports multi-track recording via USB, making it easy for users to capture performances directly to a computer.

In terms of connectivity, the Dynacord DPM 4000 excels with multiple options including XLR, TRS, and RCA inputs. Its flexible routing capabilities enable sound engineers to customize their signal flow, enhancing both versatility and convenience during live performances. Additionally, the mixer supports remote control through dedicated software applications, enabling users to manage settings from a distance, a significant advantage for live sound applications.

The DPM 4000 features advanced thermal management technology, ensuring the unit remains cool during long operational periods. This is critical for maintaining optimal performance and longevity. The built-in power amplifier delivers impressive wattage, suitable for driving various loudspeaker systems while maintaining sound clarity and fidelity.

Another notable characteristic is its rugged construction, built to withstand the rigors of touring and frequent usage. The design ensures durability in diverse environmental conditions while maintaining aesthetic appeal.

In summary, the Dynacord DPM 4000 is a versatile and powerful digital power mixer, offering a blend of user-friendly features, comprehensive control, and robust performance. Whether used in a live sound setting or for recorded sessions, it stands out as an exceptional tool for audio professionals committed to delivering high-quality sound.