396P + 396PVP Sensors Instruction Manual

Section 1: Description and Specifications

LIQ_MAN_396P_396PVP

August 2013

 

 

The 396PVP Sensor has similar features to the 396P. However, the 396PVP is offered with the Variopol (VP) connector and uses a mating VP cable (purchased separately).

A Variopol cable is required for all new installations. See below for cable selection.

Variopol connector shown with

The 396PVP insertion/ submersion sensor

mating variopol cable receptacle

with the VP (Variopol) connector

396PVP TUpH INSERTION/SUBMERSION POLYPROPYLENE pH/ORP SENSOR

CODE

MEASURING ELECTRODE

10

pH GPLR Glass, General Purpose Low Resistivity (0 - 14 pH)

12ORP

13GPLR Flat Bulb, General Purpose Low Resistivity (2 - 13 pH)

CODE

MEASURING ELECTRODE

50

For use with Model 1181pH/ORP (3K TC)

54For use with Models: 1054, 2054; Series 2081 (Pt-100)

55For use with Models: 54, 56, 1055, 1056, 1057, 81,3081, 4081, 5081, 6081 XMT (Pt-100)

CODE

OPTIONAL

No Selection

41

Slotted Tip

 

 

CODE

PREAMPLIFIER OPTION

No Preamplifier

70

With Integral Smart Preamplifier for 396PVP; available with 396PVP-10-55 and 396PVP-13-55 only

Examples of all sensing tip offerings

Shrouded Tip is

Optional Slotted Tip

Flat Tip is available

standard on all

is available on all hemi

with flat glass bulb

hemi bulb sensors

bulb sensors, ordered

sensors

 

as option -41

 

Description and Specifications

5

Image 11
Contents TUpH Combination pH/ORP Sensors This page left blank intentionally Essential Instructions About This Document Contents Table of Contents Features and Applications Description and SpecificationsDescription and Specifications Available pH Accuglass Types Gplr hemi or flat glass Specifications GeneralPercent Linearity Ordering InformationExamples of all sensing tip offerings Extension Cables required when using a remote junction box AccessoriesMounting InstallationUnpacking and Inspection Flow Through and Insertion Mounting InstallationFlow-Through Tee with Adapter PN 40396P02 40396P03 Spray Wash Assembly PN General WiringWiring for 396P-01 Gray Cable WiringWiring for 396PVP Gray Cable and 54e pH/ORP Wiring for 396PVP 11. Wiring for Dual 396P-02 13. Wiring for 396P-01 Gray Cable and 1056/56 17. Wiring for 396PVP Gray Cable 20. Wiring for 396P-01 Gray Cable 3Wiring 27. Wiring for 396P-01 Blue Cable 29. Wiring for 396P-02 Blue Cable 31. Wiring for 396PVP Blue Cable 33. Wiring for 396P-01 Gray Cable and 5081-P-HT 37. Wiring for 396PVP Gray Cable and 5081-P-HT 41. Wiring for 396P-01 Gray Cable 43. Wiring for 396P-02 Gray Cable 45. Wiring for 396PVP Gray Cable 47. Wiring for 396P-01 Gray Cable and Xmt 51. Wiring for 396PVP Gray Cable and Xmt Wiring Wiring This page left blank intentionally 396P and 396PVP pH Sensors Start-Up and CalibrationStart-Up & Calibration 396P and 396PVP ORP Sensors396P & 396PVP pH Sensors MaintenanceAutomatic Temperature Compensator General Information396P and 396PVP ORP MaintenanceCleaning Platinum Electrode This page left blank intentionally Troubleshooting with Advanced Diagnostics Diagnostics and TroubleshootingDiagnostics & Troubleshooting Troubleshooting without Advanced DiagnosticsDescription Diagnostics & Troubleshooting Warranty This page left blank intentionally Return of Material Warranty RepairNon-Warranty Repair Emerson Process Management