TABLE 6-3. Model 396P and 396PVP pH/ORP Replacement Parts and Accessories

 

 

 

 

 

PN

DESCRIPTION

 

QUANTITY

11275-01

Sensor Handrail Mounting Assembly

 

 

 

 

 

 

2002011

Flow Cell, CPVC, 1 inch FNPT

 

 

 

 

 

23242-02

Mounting Adapter, Insertion, 1￿-inch MNPT (304 S.S.) X 1” FNPT (PEEK)

 

 

 

 

 

23309-03

Junction Box, for remote preamplifier Code-50

 

 

 

 

 

 

23309-04

Junction Box, for remote preamplifier Code-54

 

 

 

 

 

23646-01

Cable, Extension (Prepped) for Models 54, 81, 3081, 4081, and 5081

 

 

 

 

23555-00

Junction Box with preamplifier, Models 54, 81, 3081, 4081, and 5081 compatible

 

 

 

 

23557-00

Preamplifier, remote for Junction Box, Models 54, 81, 3081, 4081, and 5081 compatible

 

 

 

 

22698-00

Preamplifier, Plug-in, Model 1003 compatible (for Code 02-50)

1

 

 

 

22698-02

Preamplifier, Plug-in, Models 1181 and 1050 compatible (for Code 02-50)

1

 

 

 

22698-03

Preamplifier, Plug-in, Models 1054, 1054A, 1054B, 2054, and 2081 compatible (for Code 02-54)

1

 

 

 

 

22719-02

Junction Box, w/o Preamplifier

 

 

 

 

 

 

33081-00

Adapter Insert, PEEK, 1 X 3/4-inch, for 23242-02

 

 

 

 

 

 

7901631

Shroud, PVC

 

 

 

 

 

9200254

Cable, 4 conductor, 22 AWG, shielded pair, for 1054/A/B, 2054, and 1181

 

 

 

 

9200273

Cable, Extension (Unprepped) for Models 54, 81, 3081, 4081, and 5081

 

 

 

 

23645-06

15 ft (4.6 m) cable with mating VP connector with BNC on transmitter end

 

 

 

 

23645-07

15 ft (4.6 m) cable with mating VP connector with bare wires on transmitter end

 

 

 

 

 

9210012

Buffer Solution, 4.01pH, 16 oz

 

4

 

 

 

 

9210013

Buffer Solution, 6.86pH, 16 oz

 

4

 

 

 

 

9210014

Buffer Solution, 9.18pH, 16 oz

 

4

 

 

 

 

9322014

Union, KYNAR1

 

 

9320057

Union, PVC

 

 

 

 

 

 

9120516

BNC Adapter

 

 

 

 

 

 

915240-04

Tee, Flow-through, 2” PVC, 1” NPT

 

 

 

 

 

 

9550175

O-ring for Mounting Adapter (23242-02)

 

 

 

 

 

 

R508-160Z

ORP Standard Solution, 460mV ±10 at 20°C

 

 

 

 

 

23550-00

Junction Box with Extension Board, Models 54, 81, 3081, 4081, and 5081 compatible

 

 

 

 

 

661-898695

Cable 5 Conductor (for Model 2700 only)

 

 

 

 

 

 

Diagnostics and Troubleshooting

43

Image 49
Contents TUpH Combination pH/ORP Sensors This page left blank intentionally Essential Instructions About This Document Contents Table of Contents Features and Applications Description and SpecificationsDescription and Specifications Available pH Accuglass Types Gplr hemi or flat glass Specifications GeneralPercent Linearity Ordering InformationExamples of all sensing tip offerings Extension Cables required when using a remote junction box AccessoriesUnpacking and Inspection InstallationMounting Flow Through and Insertion Mounting InstallationFlow-Through Tee with Adapter PN 40396P02 40396P03 Spray Wash Assembly PN General WiringWiring for 396P-01 Gray Cable WiringWiring for 396PVP Gray Cable and 54e pH/ORP Wiring for 396PVP 11. Wiring for Dual 396P-02 13. Wiring for 396P-01 Gray Cable and 1056/56 17. Wiring for 396PVP Gray Cable 20. Wiring for 396P-01 Gray Cable 3Wiring 27. Wiring for 396P-01 Blue Cable 29. Wiring for 396P-02 Blue Cable 31. Wiring for 396PVP Blue Cable 33. Wiring for 396P-01 Gray Cable and 5081-P-HT 37. Wiring for 396PVP Gray Cable and 5081-P-HT 41. Wiring for 396P-01 Gray Cable 43. Wiring for 396P-02 Gray Cable 45. Wiring for 396PVP Gray Cable 47. Wiring for 396P-01 Gray Cable and Xmt 51. Wiring for 396PVP Gray Cable and Xmt Wiring Wiring This page left blank intentionally 396P and 396PVP pH Sensors Start-Up and CalibrationStart-Up & Calibration 396P and 396PVP ORP SensorsAutomatic Temperature Compensator MaintenanceGeneral Information 396P & 396PVP pH Sensors396P and 396PVP ORP MaintenanceCleaning Platinum Electrode This page left blank intentionally Troubleshooting with Advanced Diagnostics Diagnostics and TroubleshootingDiagnostics & Troubleshooting Troubleshooting without Advanced DiagnosticsDescription Diagnostics & Troubleshooting Warranty This page left blank intentionally Non-Warranty Repair Warranty RepairReturn of Material Emerson Process Management