Emerson 396PVP Accessories, Extension Cables required when using a remote junction box

Page 12

Section 1: Description and Specifications

396P + 396PVP Sensors Instruction Manual

August 2013

LIQ_MAN_396P_396PVP

 

 

Accessories

Connector cable, VP8 (required for all first time installations of VP sensors)

24281-00

15 ft. (4.6m) VP8 cable

 

 

24281-01

25 ft. (7.6m) VP8 cable

 

 

24281-03

50ft (15.2m) VP8 Cable

 

 

24281-04

100ft (30.5m) VP8 Cable

 

 

24281-06

10ft (3.0m) VP8 Cable

 

 

24281-07

20ft (6.1m) VP8 Cable

 

 

24281-08

30ft (9.1m) VP8 Cable

 

 

Remote Junction Boxes and Mounting Brackets; for use when standard cable lengths need to be extended

 

 

23555-00

Junction Box; contains preamplifier for 54e, 56, 1055, 1056, 1057, 1066, 3081, 4081, 5081, 6081, XMT

 

 

23550-00

Junction Box with board for point-to-point cable extension; use with sensors containing integral preamplifiers

 

 

2002565

Mounting Bracket Kit with mounting plate and U-bolts; use with PN 23555-00 or 23550-00 junction boxes

 

 

Extension Cables (required when using a remote junction box)

23646-01

Extension Cable, 11-conduit with shields, wires prepared for easy installation, per foot (or meter); best choice for easiest

installation

 

 

 

9200273

Extension Cable, 11-conduit with shield, raw cable (user must cut and prepare cable ends), per foot (or meter)

 

 

Calibration Accessories

 

 

9210012

Buffer Solution, pH 4.01, 16 oz (473 ml)

 

 

9210013

Buffer Solution, pH 6.86, 16 oz (473 ml)

 

 

9210014

Buffer Solution, pH 9.18, 16 oz (473 ml)

 

 

R508-8OZ

ORP Standard, 475mV, 8oz (236 ml)

 

 

Mounting Assemblies

 

 

11275-01

Handrail Mounting Assembly; includes a 6 ft straight pipe, pipe coupling, 6 ft long sweep pipe, unistrut, pipe clamps, and

mounting channels

 

 

 

2002011

CPVC flow through Tee, 1-1/2" NPT process connections

 

 

24091-00

Low Flow Cell with 1/4 inch inlet and outlet

 

 

915240-03

Tee, Flow-through, 2" PVC tee with ￿" NPT process connections and mounting adapter to eliminate cable twisting

 

 

915240-04

Tee, Flow-through, 2" PVC tee with 1" NPT process conections and mounting adapter to eliminate cable twisting

 

 

915240-05

Tee, Flow-through, 2" PVC tee with 1￿" NPT process connections and mounting adapter to eliminate cable twisting

 

 

12707-00

Jet Spray Cleaner; for use with water or air cleaning using interval timer from instrument

 

 

6

Description and Specifications

Image 12
Contents TUpH Combination pH/ORP Sensors This page left blank intentionally Essential Instructions About This Document Contents Table of Contents Description and Specifications Features and ApplicationsDescription and Specifications Specifications General Available pH Accuglass Types Gplr hemi or flat glassOrdering Information Percent LinearityExamples of all sensing tip offerings Accessories Extension Cables required when using a remote junction boxInstallation Unpacking and InspectionMounting Installation Flow Through and Insertion MountingFlow-Through Tee with Adapter PN 40396P02 40396P03 Spray Wash Assembly PN Wiring GeneralWiring Wiring for 396P-01 Gray CableWiring for 396PVP Gray Cable and 54e pH/ORP Wiring for 396PVP 11. Wiring for Dual 396P-02 13. Wiring for 396P-01 Gray Cable and 1056/56 17. Wiring for 396PVP Gray Cable 20. Wiring for 396P-01 Gray Cable 3Wiring 27. Wiring for 396P-01 Blue Cable 29. Wiring for 396P-02 Blue Cable 31. Wiring for 396PVP Blue Cable 33. Wiring for 396P-01 Gray Cable and 5081-P-HT 37. Wiring for 396PVP Gray Cable and 5081-P-HT 41. Wiring for 396P-01 Gray Cable 43. Wiring for 396P-02 Gray Cable 45. Wiring for 396PVP Gray Cable 47. Wiring for 396P-01 Gray Cable and Xmt 51. Wiring for 396PVP Gray Cable and Xmt Wiring Wiring This page left blank intentionally Start-Up and Calibration 396P and 396PVP pH Sensors396P and 396PVP ORP Sensors Start-Up & CalibrationMaintenance Automatic Temperature CompensatorGeneral Information 396P & 396PVP pH SensorsMaintenance 396P and 396PVP ORPCleaning Platinum Electrode This page left blank intentionally Diagnostics and Troubleshooting Troubleshooting with Advanced DiagnosticsTroubleshooting without Advanced Diagnostics Diagnostics & TroubleshootingDescription Diagnostics & Troubleshooting Warranty This page left blank intentionally Warranty Repair Non-Warranty RepairReturn of Material Emerson Process Management