Section 1: Description and Specifications

396P + 396PVP Sensors Instruction Manual

August 2013

LIQ_MAN_396P_396PVP

 

 

FIGURE 1-1. Cross Section Diagram of the TUpH Reference Technology. All TUpH sensors are designed with a large area reference junction, helical reference pathway, and an AccuGlass pH glass bulb. This sensor technology ensures superior performance while only requiring minimal maintenance.

allows the process to flow by the glass electrode for accurate and reliable pH measurement. Both pH glass bulbs — the standard hemi or optional flat pH glass — are exceptional for increased resist- ance to high temperature and other effects of aging for longer life.

The TUpH reference junction and helical pathway combined with the AccuGLASS pH glass performs exceptionally well in dirty, high solid applications and requires only minimum mainte- nance. This is the toughest pH sensor on the market and is still unmatched by all other pH sensors. The constant increase in demand for the TUpH sensor proves it's success as the best process industry pH sensor.

All TUpH sensor models have been specifically designed for improved life in harsh, dirty, and abra- sive applications such as lime slurry, waste treatment, paper machine headbox, and pigment/dye applications, where large quantities of suspended solids are present. Various sensor materials, depending on the sensor model, are available for a variety of different application needs.

SMART is the standard option. A preamplifier converts the high impedance pH signal into a stable, noise-free signal and must be used with all pH sensors. An integral SMART preamplifier stores calibration information and can be built into the sensor when ordering the SMART pream- plifier option. Otherwise, a standard preamplifier can be used in a junction box or built into the analyzer/transmitter. All integral preamplified SMART TupH Sensors are compatible with all Rose- mount Analytical instruments.

The 396VP, 396PVP, and 396RVP are offered with a watertight VP sensor-to-cable connector which eliminates rewiring and cable twisting when replacing sensors. The VP (Variopol) multiple pin connector is an integral part of each sensor model and uses a mating VP cable. Once the cable is installed and wired to the analyzer, sensors are easily replaced without replacing the cable, without rewiring the analyzer (if the replacement sensor is the same as its predecessor). Also the sensor can be disconnected from the cable before removal from the process which eliminates cable twisting. VP8 cable assemblies work with all VP sensors. VP8 wiring is standard across all pH sensor families. VP8 is required when used with SMART preamplified sensors.

2

Description and Specifications

Image 8
Contents TUpH Combination pH/ORP Sensors This page left blank intentionally Essential Instructions About This Document Contents Table of Contents Description and Specifications Features and ApplicationsDescription and Specifications Specifications General Available pH Accuglass Types Gplr hemi or flat glassOrdering Information Percent LinearityExamples of all sensing tip offerings Accessories Extension Cables required when using a remote junction boxMounting InstallationUnpacking and Inspection Installation Flow Through and Insertion MountingFlow-Through Tee with Adapter PN 40396P02 40396P03 Spray Wash Assembly PN Wiring GeneralWiring Wiring for 396P-01 Gray CableWiring for 396PVP Gray Cable and 54e pH/ORP Wiring for 396PVP 11. Wiring for Dual 396P-02 13. Wiring for 396P-01 Gray Cable and 1056/56 17. Wiring for 396PVP Gray Cable 20. Wiring for 396P-01 Gray Cable 3Wiring 27. Wiring for 396P-01 Blue Cable 29. Wiring for 396P-02 Blue Cable 31. Wiring for 396PVP Blue Cable 33. Wiring for 396P-01 Gray Cable and 5081-P-HT 37. Wiring for 396PVP Gray Cable and 5081-P-HT 41. Wiring for 396P-01 Gray Cable 43. Wiring for 396P-02 Gray Cable 45. Wiring for 396PVP Gray Cable 47. Wiring for 396P-01 Gray Cable and Xmt 51. Wiring for 396PVP Gray Cable and Xmt Wiring Wiring This page left blank intentionally Start-Up and Calibration 396P and 396PVP pH Sensors396P and 396PVP ORP Sensors Start-Up & CalibrationMaintenance Automatic Temperature CompensatorGeneral Information 396P & 396PVP pH SensorsMaintenance 396P and 396PVP ORPCleaning Platinum Electrode This page left blank intentionally Diagnostics and Troubleshooting Troubleshooting with Advanced DiagnosticsTroubleshooting without Advanced Diagnostics Diagnostics & TroubleshootingDescription Diagnostics & Troubleshooting Warranty This page left blank intentionally Return of Material Warranty RepairNon-Warranty Repair Emerson Process Management