Emerson 396PVP instruction manual Description and Specifications, Features and Applications

Page 7

396P + 396PVP Sensors Instruction Manual

Section 1: Description and Specifications

LIQ_MAN_396P_396PVP

August 2013

 

 

Section 1: Description and Specifications

1.1Features and Applications

TUpHpH/ORP-sensors are now offered with SMART capabilities. SMART option becomes enabled when used with the 1056, 1057, 1066, and 56 Analyzers and on 6081P wireless trans- mitter. The pH-loop capabilities include auto-recognition of the SMART sensor, automatic upload of calibration data and associated time stamp, historical recording of pH diagnostics (slope, offset, reference impedance, glass impedance). This trending data allows technicians to predict frequency of maintenance and estimate sensor life for a particular process condition. Additional SMART features include factory calibration, resetting SMART sensor calibration data with user menus, and manufacturing information.

The TUpH large area reference junction for minimum maintenance requirements: The reference junction provides an electrical connection between the reference electrode and the sample, and helps maintain a stable reference potential, regardless of the change in sample pH. The TUpH reference electrode junction, the entire plastic tip surrounding the glass pH electrode, maintains a steady reference signal even in the dirtiest of applications because it resists plugging (a common cause of pH signal drift). This large reference junction area is made of micron sized reference pathways used for ionic exchange so it resists plugging by large particles and will continue to send a steady pH signal, even in the dirtiest of applications. The TUpH reference junction technology has been field-proven for minimum maintenance requirements.

The TUpH helical reference pathway stops reference poisoning. Ions diffuse through the reference pathways and a charge is passed to the reference element. The reference element must be protected from contamination by poisoning ions such as sulfide, mercury, cyanide, and ammonia or else the pH signal will drift. The TupH sensor's long internal helical reference pathway hinders and slows down the rate of contaminants migrating to the reference element therefore providing for a longer sensor life.

The entire line of TUpH model sensors now incorporate the new SILCOREtechnology contami- nant barrier. This triple-seal barrier prevents moisture and material impurities from migrating to the pH sensor’s reference electrode’s metal lead wire. By preventing these contaminants from compromising the integrity of the pH measurement, sensor life is increased, especially at higher temperatures where increased migrations occur. In addition, the SILCORE technology provides added protection against sensor failure due to vibrations and shock by transferring damaging energy away from the glass-to-metal seal.

The AccuGLASSpH glass formulations exceed industry standards. The AccuGlass pH glass is a result of many years of glass research resulting in a formulation which has been found to increase the life of the sensor. Unlike other pH glasses presently on the market, this glass resists cracking especially at higher temperatures and reduces sodium ion error commonly found in high pH applications. Overall, the AccuGlass formulation enhances the sensor performance to measure pH more accurately and have a longer sensor life than ever before.

A choice of flat or hemi glass pH glass electrodes is available to best meet various application needs. Flat glass is advantageous in abrasive or coating applications that etch or build up on glass, respectively. In coating applications, such as slurries, the flat surface allows the process flow to act as a scrubbing agent to reduce coating and maintenance. In abrasive applications pitting from silicates and other similar materials is minimized by the flat glass surface to provide longer sensor life. Flat glass sensors are offered with a flat tip which is flush with the flat glass. The hemi bulb glass is ideal for general purpose use and for those processes requiring greater accuracy over the entire pH range. All hemi bulb sensors are offered with a standard shrouded tip which completely surrounds the glass bulb for protection against solids. An optional slotted tip is also available and

Description and Specifications

1

Image 7
Contents TUpH Combination pH/ORP Sensors This page left blank intentionally Essential Instructions About This Document Contents Table of Contents Features and Applications Description and SpecificationsDescription and Specifications Available pH Accuglass Types Gplr hemi or flat glass Specifications GeneralPercent Linearity Ordering InformationExamples of all sensing tip offerings Extension Cables required when using a remote junction box AccessoriesUnpacking and Inspection InstallationMounting Flow Through and Insertion Mounting InstallationFlow-Through Tee with Adapter PN 40396P02 40396P03 Spray Wash Assembly PN General WiringWiring for 396P-01 Gray Cable WiringWiring for 396PVP Gray Cable and 54e pH/ORP Wiring for 396PVP 11. Wiring for Dual 396P-02 13. Wiring for 396P-01 Gray Cable and 1056/56 17. Wiring for 396PVP Gray Cable 20. Wiring for 396P-01 Gray Cable 3Wiring 27. Wiring for 396P-01 Blue Cable 29. Wiring for 396P-02 Blue Cable 31. Wiring for 396PVP Blue Cable 33. Wiring for 396P-01 Gray Cable and 5081-P-HT 37. Wiring for 396PVP Gray Cable and 5081-P-HT 41. Wiring for 396P-01 Gray Cable 43. Wiring for 396P-02 Gray Cable 45. Wiring for 396PVP Gray Cable 47. Wiring for 396P-01 Gray Cable and Xmt 51. Wiring for 396PVP Gray Cable and Xmt Wiring Wiring This page left blank intentionally 396P and 396PVP pH Sensors Start-Up and CalibrationStart-Up & Calibration 396P and 396PVP ORP Sensors396P & 396PVP pH Sensors MaintenanceAutomatic Temperature Compensator General Information396P and 396PVP ORP MaintenanceCleaning Platinum Electrode This page left blank intentionally Troubleshooting with Advanced Diagnostics Diagnostics and TroubleshootingDiagnostics & Troubleshooting Troubleshooting without Advanced DiagnosticsDescription Diagnostics & Troubleshooting Warranty This page left blank intentionally Non-Warranty Repair Warranty RepairReturn of Material Emerson Process Management