MINIMAX NT LOW NOx HSI ELECTRONIC IGNITION LIGHTING/OPERATION - NATURAL GAS

FOR YOUR SAFETY: READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage.

Do not attempt to light the heater if you suspect a natural gas leak. Lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage.

A.This heater is equipped with an ignition device which automatically lights the main burners. Do not try to light the burners by hand.

B.BEFORE OPERATING, smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any heater.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the Fire Department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D.Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

E.The MiniMax NT Low NOx incorporates the Pentair temperature controller 7800 to aid you in the operation of the heater, and to assist in diagnosing a failure in the heater’s function.

OPERATING INSTRUCTIONS

1. STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off electric power to the heater.

4.This heater is equipped with an ignition device which automatically lights main burners. Do not try to light the burners by hand.

5.Remove the control access door.

6.Push in gas control knob slightly and turn clock-

wise to “OFF”. (If not on “OFF” position.)

7.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8.Turn knob on gas control counterclockwise to “ON”; see Figure 1.

9.Replace the control access door.

10.Turn on the electrical power to the heater.

11.Set the thermostat to the desired setting.

12.If the heater will not operate, follow the instruc- tions "To Turn Off Gas To Heater" and call your service technician or gas supplier.

Gas

Inlet

ON

OFF

Figure 1. Gas control knob shown in “ON” position.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the heater if service is to be performed.

3.Remove control access door.

4.Push in gas control knob slightly and turn

clockwise to "OFF". Do not force.

5.Replace control access door.

Rev. C 11-1-01

P/N 471593

Image 5
Contents For additional free copies of this manual call 800 MiniMax NT Low NOx Series Table of Contents Code Requirements MiniMax NT Low NOxOperation Warranty InformationSafety Rules Operation Lighting For Your Safety Read Before LightingSpecifications Installation InstructionsELECTRICAL, ALL HSI Units Installation ElectricalInstallation Remotes TWO-WIRE or THREE-WIRE Remote HOOK-UPWire Remote Three-wire remote Wiring Installation Single VoltageVoltage Installation SingleMiniMax NTLow Code or Superceding Local Wiring CodesPlumbing Connections Water ConnectionsPlumbing GAS Connections Indoor VENTING-General Requirements Installation IndoorSee page 17 for Indoor Vent Adaptors Indoor Vent Adaptors Fits ALL Models Indoor InstallationVentilation Installation OutdoorBasic Operation General DescriptionBasic System Operation AIR Pressure FAN Switch Safety ControlsWater Pressure Switch Typical Water Pressure SwitchOperation of Ignition Module General Pentair Temperature Controller 7800 LayoutBasic Thermostat Operation Normal Operation no RemoteTemperature & Time Setting Programming To Change the Factory Temperature SettingsTime Setting Time Setting Programming Time SETTING, cont’dMaintenance Maintenance InstructionsEnergy Saving Tips Spring and Fall OperationChemical Balance Maintenance Water TreatmentPool and SPA Water If pH becomes too high over alkaline, it has these effectsNormal Operation Sequence Troubleshooting-Normal Operation Sequence of HeaterPower Service Current Temp SET TEMP/TIME Troubleshooting-Normal Operation of HeaterTroubleshooting & Service Flame Sensor Current Check Service CHECKS-IGNITION ModuleService Checks Heater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax NT LOW NOx Heater Single Voltage Description QTY Minimax NT LOW NOx Heater Dual Voltage MiniMax NT Low NOx Dual Voltage Replacement parts Rev. C Rev. C Rev. C MiniMax NT Low NOx Heaters Limited Warranty