Raypak recommends the installation of an air bleed vent at a suitable location (usually the highest point) to remove air from the piping system. These units should be available at your local wholesale supplier. Raypak does not provide this item.

CAUTION:

Power to the heater should be interlocked with the main system pump to make sure the heater does not fire without the main system pump in operation.

Improper flow control can damage the heater. Uncontrolled flow (too high) or restricted flow (too low) can seriously affect heater operation. Follow these instructions to make sure your heater is properly installed.

Models 1287 through 4001 are equipped with an external pump and bypass arrangement that blends outlet water with the inlet to increase the inlet water temperature, thereby reducing the likelihood of condensation forming on the heat exchanger. The pump also serves to circulate water through the heater from the main system piping.

To complete the installation of the pool heater, the pool thermostat needs to be installed in the main return water line. This will ensure that the heater will be energized at the right time. If the main water line is too far away from the heater and the capillary bulb will not reach it, locate the pool thermostat adjacent to the main line and run wires back to the heater. Follow the instructions listed below to install the pool stat.

MOUNTING THE POOLSTAT CONTROL WITH FRONT-MOUNTED LOOP USING MOUNTING SLOTS

For heater models:

1287, 1336, 1414, 1468, 1571, 1631, 1758, 1826, 2100, 2500, 3001, 3500, 4001.

Note: For more detail on piping, see figures 9268 and 9269.

1. Remove the poolstat control cover by removing the two cover

 

screws at the top. See Figs. 1 & 2.

 

2. Lace metal strapping or clamps, (NOT PROVIDED) through the ¾”

 

slots on the cover and fasten securely to pipe as shown in Figs. 3

Fig. 1: Poolstat Control

& 4. NOTE: Do not over-tighten clamps.

 

3.Remove either the left or right “knock-out” for wiring on the poolstat control as shown in Fig. 5.

4.Attach appropriate conduit and connectors to the poolstat control.

5.Attach wires to the poolstat wire terminals. See Fig.6.

6.Install poolstat control to the cover and fasten cover screws.

7.Poolstat should be mounted level as shown in Fig. 7.

Fig. 2: Control Cover

Fig. 3: Hose Clamp Slots

Fig. 4

Fig. 5

Fig. 6

Fig. 7

10

Image 10
Contents Installation and Operating Instructions Raythermtm Contents Important Notice Base InstallationCode Requirements Outdoor Heaters ClearancesALL Heaters Outdoor Heaters ModelsVentingconnections Z223.1/NFPAGAS Supply Connections FIG. #8090.0Waterconnections Pipe Sizing for GAS ConnectionsLocation Automatic Chlorinators and Chemical Feeders Water Pressure SwitchControls Unitherm Governor OperationModels 1287/1336 1758/1826 Flow RATES/WATER ConnectionsPoolstat Control Page To adjust the temperature Models 2100 thru Pool Stat Temperaturecontrols HighlimitsLOW Water CUT-OFF Electrical Wiring High & LOW GAS Pressure SwitchesElectronic Ignition Wiring Diagram Models 926 Wiring Diagram MODELS1287-1826 Wiring Diagram Models Wiring Diagram Models Pressure Switch TemperaturecontrolPressure Switch Adjustment START-UPPROCEDURES Main Burner Flame InspectionproceduresAfter START-UP ControlsTube Cleaning Procedure Typical Servicing ProceduresRaypak Tube Cleaning KIT Burner Drawer Removal Pilot Removal and CleaningHeat Exchanger Reassembly GAS Valve RemovalProcedure for Cleaning Flue GAS Passageways Control Well ReplacementTube Replacement Procedure Unitherm Governor ReplacementMaintenanceandcare WinterizationSolution Mechanical for Qualified Service Personnel onlyProblem CauseThis does not take into account heat Electrical Electronic Ignition IID IID High VoltageReplacement Parts List Page Page Page Models 2100, 2500, 3001, 3500 Page Page To Make Warranty Claim Heat Exchanger WarrantyParts Replacement Exclusive Warranty Limitation of LiabilityLitho in U.S.A