MODELS
UNITHERM GOVERNOR
INLET/OUTLET HEADER
OUTLET
INLET
Fig. #8224.0
GASKET
UNITHERM GOVERNOR
WITH POWER ELEMENT
MODELS
DOUBLE EXTERNAL U.G.
MODELS
EXTERNAL U.G.
TotestoperationofUnithermGovernor,placeinhotwater and watch for movement against spring. If no movement, replace.
MAINTENANCEANDCARE
To be followed one month after initial
1.Inspect top of heater and
CAUTION: Soot may be combustible. Wet completely when cleaning.
2.Clean main burners and pilot burner of dust and lint.
3.Inspect and operate all controls and gas valve. 4.Make visual check of burner and pilot flame. Flame
pattern on main burner and pilot is indicated above. Yellow flame means restriction of air openings. Lifting or blowing flame indicates high gas pressure. Low flame means low gas pressure.
5.Clean room air intake openings to ensure adequate flow of combustion and ventilation air.
6.Remove header opposite inlet pipes when cleaning and inspect internal tubes for scale deposits. If scale does not form within first quarterly inspection, then inspect annually thereafter.
CAUTION: Combustion air must not be contaminated by corrosive chemical fumes which can damage the heater and void the warranty.
7.Keep heater air clear and free from combustible materials and other flammable and corrosive vapors and liquids.
8.Keep moving parts lubricated.
9.Manual operation of pressure/temperature relief valve at least once a year.
SPA WATER CHEMISTRY
NOTE: Chemical imbalance can cause severe damage to your heater and associated equipment. Maintain your water pH between 7.2 and 7.8, and total alkalinity between 100 and 150 ppm. If the mineral content and dissolved solids in the water become too high, scale forms inside the heat exchanger tubes, reducing heater efficiency and also damaging the heater. If the pH drops below 7.2, the heater will be severely damaged.
NOTE: Heat exchanger damage resulting from chemi- cal imbalance is not covered under the warranty.
WINTERIZATION
WINTERIZING YOUR HEATER
When heaters installed outdoors in freezing climate areas are to be shut down for the winter, please observe the following
1.Remove the drain plug or open the drain cock located on the
return header. Remove return header.
26