Raypak P-R405A, RP2100 Millivolt System, Lighting Instructions, To Turn OFF GAS to Appliance

Page 4

CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined areas, extra care should be exercised when lighting propane heaters.

LIGHTING INSTRUCTIONS AND SHUT-OFF PROCEDURES

MANUALLY LIGHTED PILOTS

MILLIVOLT SYSTEM

A.This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS: *Do not try to light any appliance.

*Do not touch any electric switch; do not use any phone in your building.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explo- sion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified serv- ice technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn On/Off switch to the "Off" position.

4.Remove heater door panel.

5.Push in gas control knob slightly and turn

clockwise to "Off".

NOTE: Knob cannot be turned from "Pilot" to Off" unless knob is pushed in slightly. Do not force.

6.Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Locate pilot mounted on the right side panel of the burner drawer. For burner drawer location, see location of control section, page 20.

GAS CONTROL KNOB SHOWN IN OFF POSITION

HONEYWELL

GAS VALVE

MILLIVOLT

ROBERTSHAW

Fig. # 8081.0GAS VALVE

MILLIVOLT

HONEYWELL PILOT

ROBERTSHAW PILOT

Fig. # 8083.0

Fig. # 8084.1

8.Turn knob on gas control counter-clockwise

to "Pilot"

9.Place flame to end of pilot tube. Push in control knob all the way and hold to light pilot. Continue to hold control knob in for about one minute after the pilot is lighted, release knob and it will pop back up. Pilot should remain lighted. If it goes out, repeat steps 5 through 9. *If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

10.Stand to the side of the heater and turn the gas

control knob counter clockwise to "On".

11.Replace heater door panel.

12.Turn On/Off switch to the "On" position.

13.Set thermostat to the desired setting.

Fig. # 8079.0

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn On/Off switch to the "Off" position.

3.Remove heater door panel.

4.Push the gas control knob slightly and turn

clockwise to "Off". Do not force.

5.Replace heater door panel.

4

Image 4
Contents Installation Operating Instructions What to do if YOU Smell GASContents START-UP Procedures Before START-UPBurners WaterLighting Instructions Millivolt SystemTo Turn OFF GAS to Appliance What to do if YOU Smell GAS Electronic Ignitions SystemsOperating Instructions Maintenance and Care Procedures Water Pressure SwitchAfter START-UP Visual InspectionBasic Tips if Heater will not Fire Pool & SPA Water ChemistryAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS ColdweatheroperationGeneral Specifications Receiving EquipmentWinterizing the Pool & SPA Heater Standard Unit Asme UnitInstallation Instructions Heater with Outdoor Stackless TOP Feet horizontallyIndoor Heater Outdoor KIT IncludesSecuring the top panel cover- Indoor KIT only Installing the top cover- Outdoor KIT only Specifications and Dimensions Combustion AIR Indoor Units OnlyVent Piping GAS Supply ConnectionsGAS Pressure Adjustment Locations GAS Pressure RegulatorPipe Sizing for GAS Connections Plumbing for Water ConnectionsFlow Rates Model Pipe Size MIN.GPM MAX.GPM ConnectionsplasticheaderINLET/OUTLETHEADER Companionflangeconnections CastironheaderAuxiliary Bypass Valve Adjustment Pressure Relief Valve InstallationUnithermgovernoroperation Internal Automatic BY-PASS ValveRP2100+ Heat Exchanger Reversal Procedure Jaco Fitting Electricalwiring Millivolt SystemELECTRONICINTERMITTENTIGNITIONDEVICESYS- TEM IID AtmosphericWiring Diagram KEY Wiring Diagram Millivolt Units With Mechanical ThermostatWiring Diagram IID Units atmospheric Wiring Diagram IID Units Low NOx CONTROLS/ADJUSTMENTS/REPLACEMENTS Knob Stop Shown Above is SPA Temperature RangeGeneral Location of Controls Control Panel RemovalElectroniccontrols Display FaultsDisplay Status RP2100 Remote Control Installation Two-Wire Remote OperationThree Wire TWO Function TWO Wire ONE Function ON/OFF onlyFlame ROLL-OUT Safety Switch Pressure SwitchHighlimits Honeywell Pilot Robertshaw Pilot Tube Cleaning Procedure Desooting ProcedureUnitherm Governor U.G. Replacement Combustion Chamber RemovalSTART-UP Procedures S8610B BurneradjustmentFlame ROLL-OUT Safety Switch OperationBurner Drawer Removal GAS Valve RemovalMain Burner and Orifice Removal Pilot RemovalTrouble Shooting Guide MechanicalforqualifiedservicepersonnelonlyElectrical Standing Pilot Millivolt Raypak Pool or SPA Heater Electrical Check with MV GAS ValveTroubleshooting Honeywell S8600 Electrical Electronic Ignition IIDPage Replacement Parts List RAYPAK,INC12-P Fig# Pilot Assemblies Page Page Page Page Limitedwarranty Raypakresidentialswimmingpoolandspaheaters
Related manuals
Manual 52 pages 42.2 Kb

C-R185A, P-R405A, RP2100 specifications

Raypak is a leading manufacturer in the heating and cooling industry, renowned for its innovative products that cater to both residential and commercial sectors. One of its product lines, the RP2100 series, exemplifies cutting-edge technology and features designed to enhance efficiency and performance in pool heating systems.

The RP2100 models, particularly the P-R185B through R-P405B series, incorporate advanced heat exchanger technology, enabling them to offer exceptional heat transfer efficiency. The titanium heat exchangers are designed for durability and resistance against corrosion, particularly in saltwater environments, ensuring the longevity of the system. These units are engineered for both outdoor and indoor applications, with the versatility to adapt to various heating requirements.

In terms of energy efficiency, the RP2100 series boasts a high coefficient of performance (COP), making them cost-effective solutions for pool heating. They are equipped with digital thermostats that provide accurate temperature control, ensuring consistent heating capabilities while minimizing energy consumption. The inclusion of intelligent controls allows for seamless integration with existing systems and provides users with the ability to schedule heating cycles, further enhancing energy savings.

Moving beyond the RP2100 series, the C-R185B to C-R405B models are specifically tailored for commercial applications, combining robust performance with user-friendly features. These commercial heaters are designed to handle larger volumes of water and are built to withstand the rigors of high-traffic environments, such as resorts and sports complexes. Their vertical design optimizes space and promotes better airflow, which is crucial in high-demand scenarios.

The P-R185BL to P-R405BL and C-R185BL to C-R405BL models feature noise-reducing technology, making them suitable for residential settings where peace and quiet are paramount. They utilize advanced acoustic insulation materials that minimize operational noise without sacrificing performance.

In summary, the Raypak RP2100, P-R185B to R-P405B, C-R185B to C-R405B, P-R185BL to P-R405BL, and C-R185BL to C-R405BL series represent the pinnacle of innovation in pool heating solutions. With their durable construction, energy-efficient designs, and advanced technologies, these models are ideal for users seeking reliability, efficiency, and quiet operation in both residential and commercial environments. Investing in Raypak products ensures superior heating performance, longevity, and overall satisfaction.