Generac 005028-0 Pipe Muffler OUT, Pipe Exhaust 2.5L Ford, Muffler 2.5L Ford, Saddle 2 Inch

Page 54

Section 8 - Exploded Views and Parts Lists

Liquid-cooled 15, 20 and 25 kW Generators

Muffler — Drawing No. 0F2930-C

1

 

5

4

24

 

7

6

 

 

 

 

 

11

 

 

 

 

 

 

3

 

13

 

 

 

 

15

17

 

 

 

 

 

 

 

20

 

 

 

 

20

 

 

12

 

19

 

 

 

 

11

 

 

20

 

 

 

 

 

5

4

 

6

18

 

 

 

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

 

 

 

15 14

16

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

10

 

 

 

 

 

 

2

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

23

ITEM

PART NO.

QTY.

DESCRIPTION

ITEM

PART NO.

QTY.

DESCRIPTION

1

0F2912

1

PIPE MUFFLER OUT

13

042568

4

SCREW HHC M6-1.0 X 20 G8.8

2

0F2869

1

PIPE EXHAUST 2.5L FORD

14

022097

4

WASHER LOCK M6-1/4

3

0F2823

1

MUFFLER 2.5L FORD

15

022473

8

WASHER FLAT 1/4-M6 ZINC

4

036434

2

BOLT U 5/16-18 X 2.09

16

049813

4

NUT HEX M6 X 1.0 G8 YEL CHR

5

036449

2

SADDLE 2 INCH

17

039253

2

SCREW HHC M8-1.25 X 20 G8.8

6

022129

6

WASHER LOCK M8-5/16

18

045771

2

NUT HEX M8-1.25 G8 YEL CHR

7

022259

4

NUT HEX 5/16-18 STEEL

19

0A4010

1

SCREW HHC M8-1.25 X 60 G8.8 FT

8

0E0170A

1

EXHAUST BLANKET 800MM

20

022145

5

WASHER FLAT 5/16-M8 ZINC

9

044149

1

GASKET EXHAUST RING

21

022131

2

WASHER FLAT 3/8-M10 ZINC

10

0E8816

1

EXHAUST FLANGE 2" PIPE

22

085917

2

WASHER LOCK 3/8 SS

11

0F2925

2

STRAP MUFFLER

23

0D2611

2

SCREW HHC 3/8-16 X 1-3/4 SS

12

0F2926

1

BRACKET, MUFFLER

24

052858

1

NUT TOP LOCK FL M8-1.25

52

Image 54
Contents This manual should remain with the unit ‹ HOW to Obtain Service Authorized Service Dealer Location‹ Operation and Maintenance IntroductionTable of Contents General Hazards Electrical Hazards ‹ Standards IndexEngineered Transfer Switch Wire Start GTS Mode Transfer SwitchAutomatic Transfer Switch ATS Mode GeneratorMain Circuit Breaker ‹ 1.8.1 LOW OIL Pressure Switch‹ 1.8.2 High Coolant Temperature Switch Generator Fuel SystemUnpacking Lifting the GeneratorSpecifications Fuel ConsumptionAWSF-52-C Before Installation Coolant RecommendationsEngine OIL Recommendations ‹ 2.1.1 Nfpa Standards Generator LocationGenerator Mounting Support ‹ 2.1.2 Other Published StandardsGrounding the Generator Basic Standby Electric SystemTotal Circuit Isolation Method Emergency Circuit Isolation MethodConnection Diagram ATS Mode Generator AC Neutral ConnectionsConnection Diagram GTS Mode Battery Installation ‹ 2.11.1 Vented BatteriesPreparation Before START-UP Control Console Components Manual Transfer START-UPEngine Governor Gain Adjustments Bat Red Oil Red Temp Red Speed Red Crank RedManual Retransfer Shutdown Automatic OperationWeekly Exercise Cycle Control Board DIP Switch Settings Voltage Regulator AdjustmentExhaust Manifold Procedure Intake Manifold ProcedureOverload Protection for Engine DC Electrical System Cylinder Head ProcedureCooling System Checking Fluid Levels‹ 4.7.3 Engine Coolant ‹ 4.7.2 Battery Fluid ‹ 4.8.6 Perform Visual Inspection‹ 4.8.2 Check Battery ‹ 4.8.1 Check Engine OIL Level‹ 4.9.1 Cleaning the Generator Miscellaneous Maintenance‹ 4.8.11 Changing the Engine AIR Cleaner ‹ 4.8.13 Coolant Change‹ 4.9.3 Battery Maintenance ‹ 4.9.4 Battery ReplacementPeriodic Replacement Parts Scheduled Maintenance Service Maintenance Interval InformationLevel Maintenance Level Troubleshooting Points Problem Cause CorrectionLiquid-cooled 15, 20 and 25 kW Generators Liquid-cooled 15, 20 and 25 kW Generators Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Page Assembly Battery Tray Support Battery TrayHold Down Battery Battery Post Cover BlackTo B Duct Intake MID AL 2.5L Assy Wire 14AWG 7.5 #0 GRN/YELDoor Battery Compartment Duct Discharge RH AL 2.5LPage Hang TAG 2 Wire Start not Shown Switch ROC Dpst 125V SPDSwitch ROC Dpdt ON-OFF-ON TOP, Control PanelPage Harness Ctrl PNL 2.5L Ford AL not Shown 13 17 STARTER, 12 Volt Tank Coolant RecoveryEngine 2.5L Ford NUT HEX M10-1.5 G8 YEL CHRTo Engine GASKET, AIR Cleaner Adapter Body Carburetor AssemblyCover AIR Cleaner Bracket Fuel RegulatorLocktight Rotor 390 25KW 1P Direct HSB 2.5L Ford Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 40KW 1P Direct HSB 3.9L ChryslerMuffler 2.5L Ford Pipe Muffler OUTPipe Exhaust 2.5L Ford Saddle 2 InchASM Motor Stepper Housing Governor ConnectorCover Connector Housing Harn GOV 2.5L FordALM HOSE, 2.5L Ford LowerBarbed STR 1/4 NPT X 3/8 Radiator 2.5L FordInstallation Diagram Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingThis Warranty Shall not Apply to the Following

005028-0, 005030-0, 005028-0, 005031-0 specifications

Generac's line of generator models, including the 005028-0, 005030-0, 005031-0, and their closely related variant 005028-0, represent a fusion of durability, technology, and user-centric design focused on providing reliable power solutions for residential and commercial applications.

The Generac 005028-0 model stands out with its robust construction and efficient performance. It features a powerful engine that ensures a steady supply of electricity, capable of handling essential appliances during power outages. The model incorporates Generac's patented TruePower technology, which offers clean and stable power, ensuring sensitive electronics are safe from fluctuations. This feature is particularly appealing for homeowners who rely on medical equipment or sophisticated devices that require consistent power quality.

On the other hand, the 005030-0 model takes performance up a notch by equipped with a larger fuel tank, allowing for extended runtime during outages. It also has a quieter operation compared to its counterparts, making it suitable for residential areas where noise levels are a concern. The model includes an intuitive user interface that simplifies operation, letting users monitor their generator’s status effortlessly.

Similarly, the 005031-0 model boasts enhanced technology via a fully automatic transfer switch. This feature enables seamless switching between utility power and generator power without user intervention, ensuring that homes and businesses remain powered even during unexpected power failures. Equipped with advanced safety features, this model ensures that the generator operates only when necessary, significantly extending its lifespan and maintaining efficiency.

Additionally, all these Generac models share a durable casing designed to withstand harsh weather conditions. They are engineered for easy maintenance, with oil and fuel access points conveniently located for user convenience. Furthermore, the models come with various options for fuel types, including propane and natural gas, providing users flexibility based on their needs.

In summary, Generac's 005028-0, 005030-0, and 005031-0 models are characterized by their reliable performance, advanced technology, and user-friendly features. These generators are perfect solutions for anyone seeking a dependable source of backup power, ensuring that essential equipment runs smoothly without interruptions, no matter the situation.