EMISSION CONTROL SYSTEM WARRANTY

Section 10 – Warranty

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

EMISSION CONTROL SYSTEM WARRANTY

Emission Control System Warranty (ECS Warranty) for 1995 and later model year engines:

(a)Applicability: This warranty shall apply to 1995 and later model year engines. The ECS Warranty Period shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purchaser/owner and shall con- tinue for 24 consecutive months thereafter.

(b)General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment and to each subsequent purchaser/owner that each of its engines is ...

(1)Designed, built and equipped so as to conform with all applicable regulations adopted by the CARB pursuant to its authority, and

(2)Free from defects in materials and workmanship which, at any time during the ECS Warranty Period, may cause a war- ranted emissions-related part to fail to be identical in all material respects to the part as described in the engine man- ufacturer’s application for certification.

(c)The ECS Warranty only pertains to emissions-related parts on your engine, as follows:

(1)Any warranted, emissions-related parts that are not scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(2)Any warranted, emissions-related part that is scheduled only for regular inspection as specified in the Owner’s Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary” shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(3)Any warranted, emissions-related part that is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection

(4)below. Any such emissions-related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.

(4)Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a Generac Authorized Warranty Service Facility.

(5)When the engine is inspected by a Generac Authorized Warranty Service Facility, the owner shall not be held responsi- ble for diagnostic costs if the repair is deemed warrantable.

(6)Generac shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of any emission-related part covered by the ECS Warranty.

(7)Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts.

(8)Any Generac authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repairs and will be provided without charge to the owner. Such use shall not reduce Generac ECS Warranty obligations.

(9)Unapproved, add-on, modified, counterfeit and/or “grey market” parts may not be used to modify or repair a Generac engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. Generac shall not be held liable hereunder for failures of any warranted parts of a Generac engine caused by the use of such an unapproved, add-on, modified, counterfeit and/or “grey market” part.

EMISSION RELATED PARTS INCLUDE THE FOLLOWING:

1) Fuel Metering System:

3)

Ignition System including:

1.2) LPG/Natural Gas carburetion assembly and its internal

 

a) Spark plug

components.

 

b) Ignition module

a) Fuel controller (if so equipped)

4)

Catalytic Muffler Assembly (if so equipped) including:

b) Mixer and its gaskets (if so equipped)

 

a) Muffler gasket

c) Carburetor and its gaskets (if so equipped)

 

b) Exhaust manifold

d) Primary gas regulator (if so equipped)

5)

Crankcase Breather Assembly including:

 

e) LP liquid vaporizer (if so equipped)

a) Breather connection tube

2) Air Induction System including:

 

a) Intake pipe/manifold

 

b) Air cleaner

 

*Generac engine types covered by this warranty statement include the following:

1)Prepackaged Standby Generator

2)Auxiliary Power Unit (APU) Generator

3)Standby Generator

Part 2

Generac® Power Systems, Inc. 57

Image 59
Contents DANGER POWER SYSTEMS, INCDEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY POWER SYSTEMS‹CONTENTS INTRODUCTIONAUTHORIZED DEALER LOCATION DANGERIntroduction Parts of the generator are rotating and/or hot GENERAL HAZARDSDespite the safe design of this generator ‹STANDARDS INDEX ELECTRICAL HAZARDSFIRE HAZARDS EXPLOSION HAZARDS1.3SYSTEM SET LED 1.1UNPACKING/INSPECTION1.2PROTECTION SYSTEMS Figure 1.2 - 12 kW and 15 kW, V-twin GT-990Engine 1.4YOUR GENERATORFigure 1.1 - 7 kW, Single Cylinder GH-410Engine ‹1.5.2 ENGINE 1.5 SPECIFICATIONS‹ 1.5.1 GENERATOR DANGER 1.8RECONFIGURING THE FUEL SYSTEM1.6FUEL REQUIREMENTS AND RECOMMENDATIONS 1.7FUEL CONSUMPTION1.9.1 GENERATOR 1.10 BATTERY INSTALLATION1.9LOCATION 1.9.2 TRANSFER SWITCHDo not open or mutilate the battery. Released 1.11 THE BATTERYFigure 1.5 - Battery Cable Connections Wear rubber gloves and bootsNever operate the engine with the oil level 2.2CHECK TRANSFER SWITCH OPERATION2.1BEFORE INITIAL START-UP 2.3ELECTRICAL CHECKS2.5CHECKING AUTOMATIC OPERATION 2.6ADJUSTING THE REGULATOR NATURAL GAS ONLY2.4GENERATOR TESTS UNDER LOAD Do not make any unnecessary adjustments 2.7ENGINE GOVERNOR ADJUSTMENTFigure 2.2 - Placement of Regulator Figure 2.3 - Engine Governor AdjustmentFigure 2.5 - Voltage Adjustment Potentiometer 2.8VOLTAGE REGULATOR ADJUSTMENT3.1BREAK-INPROCEDURE Figure 2.4 - Full Load Speed Adjust Screw3.4SEQUENCE OF AUTOMATIC OPERATION 3.3AUTOMATIC TRANSFER OPERATION3.2USING THE AUTO/OFF/MANUAL SWITCH FIGURE With the switch set to AUTO, the engine mayFigure 3.2 - Manual Transfer Switch Operation 3.6SETTING THE EXERCISE TIMER3.5MANUAL TRANSFER OPERATION ‹3.5.2 TRANSFER BACK TO UTILITY POWER SOURCE‹3.7.2 HIGH TEMPERATURE SWITCH 3.7PROTECTION SYSTEMS4.1FUSE ‹3.7.1 LOW OIL PRESSURE SWITCH‹4.3.1 ENGINE OIL RECOMMENDATIONS 4.2CHECKING THE ENGINE OIL LEVEL4.3CHANGING THE ENGINE OIL ‹ 4.3.2 OIL CHANGE PROCEDUREFigure 4.6 - 7 kW, Engine Air Cleaner Location 4.5CHANGING THE ENGINE AIR CLEANER4.4CHANGING THE OIL FILTER 4.6SPARK PLUGSFigure 4.8 - Setting the Spark Plug Gap 4.7BATTERY MAINTENANCE4.8ADJUSTING GH-410/GT-990VALVE CLEARANCE Figure 4.10 - Valve Clearance Adjustment 4.9COOLING SYSTEM4.10 ATTENTION AFTER SUBMERSION 4.11 CORROSION PROTECTION‹4.12.2 RETURN TO SERVICE 4.12 OUT OF SERVICE PROCEDURE‹4.12.1 REMOVAL FROM SERVICE 4.13 SERVICE SCHEDULE CORRECTION 5.1TROUBLESHOOTING GUIDEPROBLEM CAUSESection 6 - Electrical Data 24 Generac Power Systems, IncCONNECTION CONTROL PANEL BOXCUSTOMER 26 Generac Power Systems, Inc C2-6 28 Generac Power Systems, Inc Wiring Diagram - 7 kW - Drawing No. 0D9013-ACLOSEST TO BEA 4 0 STATOR CUSTOMER CONNECTION30 Generac Power Systems, Inc C2-6 32 Generac Power Systems, Inc Section 7 - Exploded Views and Parts ListsPART NO.QTY. DESCRIPTION Control Panel - Drawing No. 0D8503-E DESCRIPTION Section 7 - Exploded Views and Parts Lists 0D4801 37 17 24 0D3086 Kit Contains DESCRIPTION 42 Generac Power Systems, Inc DESCRIPTION 44 Generac Power Systems, Inc 7 kW Generator - Drawing No. 0D3504-B 46 Generac Power Systems, Inc 12 kW and 15 kW Generator - Drawing No. 0D3417-B 48 Generac Power Systems, Inc GN410 Engine - Drawing No. 0D3539-BPart 50 Generac Power Systems, Inc 0C1069 PART NO. QTY NTAKE Section 8 - Mounting DimensionsTRANSFER SWITCH Guardian Air54 Generac Power Systems, Inc Generac Power Systems, Inc Section 10 - Warranty CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONS PURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIESEMISSION RELATED PARTS INCLUDE THE FOLLOWING EMISSION CONTROL SYSTEM WARRANTYP.O. BOX WHITEWATER, WI WARRANTY SCHEDULEGENERAC POWER SYSTEMS, INC