Generac 04758-1,04759-1,04760-1 owner manual Changing the OIL Filter, ‹ 4.3.2 OIL Change Procedure

Page 20

Section 4 — Maintenance

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

‹4.3.2 OIL CHANGE PROCEDURE

To change the oil, proceed as follows:

1.Run the engine until it is thoroughly warmed up then shut OFF the engine.

2.Immediately after the engine shuts OFF, pull the oil drain hose (Figure 4.4) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container.

Figure 4.4 – Oil Drain Hose and Filter

Loosen

Oil

Drain

Hose

Oil Filter

3.After the oil has drained, replace the cap onto the end of the oil drain hose. Retain the hose in the clip.

4.Refill with the proper recommended oil (see Section 4.3.1). See Section 1.5.2 for oil capaci- ties.

4.4CHANGING THE OIL FILTER

Change the engine oil filter as follows:

1.With the oil drained, remove the old oil filter by turning it counterclockwise.

2.Apply a light coating of clean engine oil to the gas- ket of the new filter. See Section 1.5.1 for recom- mended filter.

3.Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter. Then, tighten the filter an additional 3/4 to one turn (Figure 4.4).

4.Refill with the proper recommended oil (see Section 4.3.1). See Section 1.5.2 for oil capaci- ties.

5.Start the engine and check for leaks.

4.5CHANGING THE ENGINE AIR CLEANER

‹4.5.1 7 KW, 12 KW AND 15 KW GENERATORS

See Figures 1.1 and 1.2, for the location of the air cleaner. Use the following procedure (Figure 4.6):

1.Turn the two screws counterclockwise to loosen.

2.Remove the cover and air filter.

3.Wipe away dust or debris from inside of the air box and around edges.

4.Install the new air cleaner into the air box.

5.Install the cover. Turn the two cover screws clock- wise to tighten.

See the “Service Schedule,” Section 4.13 for air cleaner maintenance. See Section 1.5.1 for air filter replacement part number.

Figure 4.6 — 7 kW, Engine Air Cleaner Location

Air Cleaner

Fuel

Regulator

 

 

 

Figure 4.7 — 12 kW and 15 kW Engine

Air Cleaner

Screw

Cover

Filter

18

Image 20
Contents Installation Introduction Post Installation Start-up Adjustments MaintenanceTroubleshooting Introduction Inside Front CoverGeneral Hazards Electrical Hazards ‹ Standards IndexSystem SET LED UNPACKING/INSPECTIONProtection Systems Generator 7 kW, Single Cylinder GH-410 Engine‹ 1.5.2 Engine Specifications‹ 1.5.1 Generator Reconfiguring the Fuel System Fuel Requirements RecommendationsFuel Consumption 1 7 KW, 410CCTransfer Switch LocationGenerator 2.1 7 kW, 12 kW and 15 kW UnitsBattery Installation BatteryElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Generator Tests Under Load Checking Automatic Operation1 7 KW Units Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment 2 12 KW and 15 KW Units Voltage Regulator AdjustmentBREAK-IN Procedure Automatic Transfer Operation Sequence of Automatic Operation‹ 3.2.1 Auto Position ‹ 3.2.2 OFF Position‹ 3.5.2 Transfer Back to Utility Power Source Manual Transfer OperationSetting the Exercise Timer ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch ‹ 3.7.3 Overcrank‹ 4.3.1 Engine OIL Recommendations Checking the Engine OIL LevelChanging the Engine OIL ‹ 4.5.1 7 KW, 12 KW and 15 KW Generators ‹ 4.3.2 OIL Change ProcedureChanging the OIL Filter Battery Maintenance Spark PlugsAdjusting Valve Clearance Cooling SystemOUT of Service Procedure ‹ 4.12.2 Return to Service‹ 4.12.1 Removal from Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Customer Battery Utility Battery Charger Utility Connection BCR SW1 Exploded Views and Parts Lists Part NO.QTY. Description Exploded Views and Parts Lists Part NO. QTY. Description 140 Part NO. QTY Description 138 122 QTY Description 28 31 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists ASSEMBLY, Connecting ROD Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome For GT 760 Engine only CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule This Warranty Shall not Apply to the Following