3.10 DRIVE BELT

The engine drives the generator rotor by means of a pulley and drive belt arrangement. Drive belt tension was properly adjusted before the unit was shipped from the factory. If you suspect that drive belt tension is incorrect, contact a Generac Authorized Service Dealer.

3.11 EXERCISING THE GENERATOR

Generac recommends that you start and operate the generator at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine.

3.12 OUT OF SERVICE PROCEDURE

3.12.1 REMOVAL FROM SERVICE

If you cannot exercise the generator every seven days, and it is to be out of service longer than 30 days, pre- pare the generator for storage as follows:

1.Start the engine and let it warm up.

2.Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.

3.While the engine is still warm from running, drain the oil completely. Refill the crankcase with SAE 5W-30 oil having API classification “For Service SF.”

4.Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase.

5.Remove the spark plug and pour two or three tablespoons of clean, fresh engine oil into the spark plug threaded openings. Reinstall and tighten the spark plug.

6.Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor.

7.Clean and wipe the entire generator.

To return the unit to service after storage, proceed as follows:

1.Check the tag on the engine for oil viscosity and classification. Verify that the correct recommend- ed oil is used in the engine (see Section 1.5.4, Page 6). If necessary, drain and refill with the proper oil.

2.Check the state of the battery. Fill all cells of unsealed batteries to the proper level with distilled water. DO NOT USE TAP WATER IN THE BAT- TERY. Recharge the battery to 100 percent state of charge, or, if defective, replace the battery.

3.Clean and wipe the entire generator.

4.Reconnect the battery. Observe battery polarity. Damage may occur if the battery is connected incorrectly.

5.Turn OFF all electrical loads. Add fuel if neces- sary and then start the engine.

6.Allow the unit to warm up thoroughly.

7.Apply electrical loads to at least 50 percent of the unit’s rated wattage capacity.

8.When the engine is thoroughly warmed up, shut it down.

9.Your generator is now ready for service.

3.13 RV GENERATOR SERVICE INTERVAL

QUIETPACT 55/65/75:

50 Hours

Clean Spark Arrestor

1st 50 Hours,

 

 

then every 500 Hours

................Adjust Valve Lash

100 Hours

Change Engine Oil/Filter

100 Hours

Clean Air Pre-filter

100 Hours

Inspect Spark Plugs

250 Hours

Replace Paper Air Filter Element

400 Hours

Replace Fuel Filter

500 Hours

Replace Spark Plugs

Generac® Power Systems, Inc. 15

Image 17
Contents This manual should remain with the unit Introduction Authorized Service Dealer LocationTable of Contents General Hazards Electrical Hazards Reference Number Identification Generator IdentificationSafety InstallationGenerator Applicability Generator AC Connection SystemFuel Requirements Gasoline Specifications1.1 Fuel Consumption gph/lbs.ph Generator Control Panel Before Starting the Engine Optional Remote START/STOP PanelAutomatic Choke Letting the Engine Stabilize Starting the GeneratorStopping the Generator LOW OIL Pressure Switch High Temperature SwitchProtection Systems Field BoostOvervoltage Protection Checking the Engine OIL Level6 25-HOUR CHECK-UP 5 25-HOUR BREAK-IN PeriodChanging the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR CleanerCleaning the Foam Precleaner Checking the Engine Spark Plug Clean Spark ArrestorBattery Maintenance Cleaning the GeneratorWeekly Every SIX MonthsRV Generator Service Interval OUT of Service ProcedureDrive Belt Exercising the GeneratorQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Standards Booklets Purpose and Scope Installation InstructionsEquipment Description Generator Engine Operating SpeedDimensions Drawing No E1058-A Generator Location Location and SupportSuspended Mounting Generator CompartmentsCompartment Size Generator RestraintTypical Compartment Construction Sound Insulating MaterialsAcoustics Cooling and Ventilating AIRCompartment Floor Cutouts Generator AirflowGasoline Fuel System Testing the InstallationParts not Included in Fuel System LP GAS Fuel SystemGenerator Fuel Supply Line Some Important Considerations Primary RegulatorVapor Withdrawal Gaseous CarburetionFuel Supply Lines Exhaust SystemLeakage Tests Excess Flow ValveElectrical Connections Exhaust System SafetyMufflers and Spark Arrestors Electrical Junction BOXIsolating Different Power Sources WiringPower Supply Cord Generator AC ConnectionsRecommended Battery Battery InstallationBattery Cables Battery Cable Connections18 Transfer Switch Isolation Method Post Installation Tests Optional AccessoriesBefore Initial START-UP Initial StartInstallation Checklist Testing Under LoadProblem Cause Correction Troubleshooting GuideQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.