Section 2 – Operation

QUIETPACT 55, 65, and 75 Recreational Vehicle Generators

2.7.2 DO NOT OVERLOAD THE GENERATOR

 

2.8.2 HIGH TEMPERATURE SWITCH

You can read the rated wattage/amperage capacity of your generator on the generator data decal (see Section 1.1 on Page 4).

Applying electrical loads in excess of the unit’s rated capacity will cause the engine/generator to automati- cally shut down.

To avoid overloading, add up the wattage of all con- nected electrical lighting, appliance, tool and motor loads. This total should not be greater than the gen- erator’s rated wattage capacity.

Most lighting, appliance, tool and motor loads indi- cate their required watts on their nameplate or data plate. For light bulbs, simply note the wattage rating of the bulb.

If a load does not show its rated wattage, multiply that load’s rated VOLTS times AMPS to obtain

WATTS.

Induction type motors (such as those that run the vehicle’s furnace fan, refrigerator, air conditioner, etc.) need about 2-1/2 times more watts of power for starting than for running (for a few seconds during motor starting). Be sure to allow for this when connecting electrical loads to the generator. First, figure the watts needed to start electric motors in the system. To that figure, add the run- ning wattages of other items that will be operated by the generator.

Do not apply heavy electrical loads for the first two or three hours of operation.

2.8PROTECTION SYSTEMS

2.8.1 LOW OIL PRESSURE SWITCH

This switch (Figure 2.3) has normally closed (N.C.) contacts that are held open by engine oil pressure during cranking and operating. Should oil pressure drop below a preset level, switch contacts close, and the engine automatically shuts down. The unit should not be restarted until oil is added.

This switch (Figure 2.3), which has normally open (N.O.) contacts, is mounted near the oil filter. The contacts close if the temperature should exceed approximately 270º F (132º C) for gasoline models, and 284° F (140° C) for LP models, initiating an engine shutdown.

Figure 2.3 – Low Oil Pressure and

High Temperature Switches

2.8.3 FIELD BOOST

The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.4). During engine cranking only, a positive DC (battery) voltage is deliv- ered through a diode, resistor, brushes, slip rings, and the generator rotor. Application of this voltage to the rotor “flashes the field” whenever it is started. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings.

Figure 2.4 – Field Boost Circuit

10 Generac® Power Systems, Inc.

Image 12
Contents This manual should remain with the unit Authorized Service Dealer Location IntroductionTable of Contents General Hazards Electrical Hazards Generator Identification Reference Number IdentificationInstallation SafetyGenerator Applicability Generator AC Connection SystemSpecifications 1.1 Fuel Consumption gph/lbs.phFuel Requirements Gasoline Generator Control Panel Optional Remote START/STOP Panel Automatic ChokeBefore Starting the Engine Starting the Generator Stopping the GeneratorLetting the Engine Stabilize High Temperature Switch LOW OIL Pressure SwitchProtection Systems Field BoostChecking the Engine OIL Level Overvoltage Protection6 25-HOUR CHECK-UP 5 25-HOUR BREAK-IN PeriodMaintaining the Engine AIR Cleaner Cleaning the Foam PrecleanerChanging the Engine OIL AND/OR OIL Filter Clean Spark Arrestor Checking the Engine Spark PlugCleaning the Generator Battery MaintenanceWeekly Every SIX MonthsOUT of Service Procedure RV Generator Service IntervalDrive Belt Exercising the GeneratorQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Purpose and Scope Installation Instructions Standards BookletsEquipment Description Generator Engine Operating SpeedDimensions Drawing No E1058-A Location and Support Generator LocationGenerator Compartments Suspended MountingCompartment Size Generator RestraintSound Insulating Materials Typical Compartment ConstructionCooling and Ventilating AIR AcousticsCompartment Floor Cutouts Generator AirflowTesting the Installation Gasoline Fuel SystemLP GAS Fuel System Generator Fuel Supply LineParts not Included in Fuel System Primary Regulator Some Important ConsiderationsVapor Withdrawal Gaseous CarburetionExhaust System Fuel Supply LinesLeakage Tests Excess Flow ValveExhaust System Safety Electrical ConnectionsMufflers and Spark Arrestors Electrical Junction BOXWiring Isolating Different Power SourcesPower Supply Cord Generator AC ConnectionsBattery Installation Recommended BatteryBattery Cables Battery Cable Connections18 Transfer Switch Isolation Method Optional Accessories Post Installation TestsBefore Initial START-UP Initial StartTesting Under Load Installation ChecklistTroubleshooting Guide Problem Cause CorrectionQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.