Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 owner manual General Hazards

Page 4

Safety Rules

QUIETPACT 55, 65, and 75 Recreational Vehicle Generators

 

SAVE THESE INSTRUCTIONS – The

manufacturer suggests that

these rules

for safe

 

!

operation be copied and posted in

potential hazard areas of the

recreational

vehicle.

!

 

Safety should be stressed to all operators and potential operators of this equipment.

 

! WARNING: !

The engine exhaust from this product contains chemicals known to the state

of California to cause cancer, birth defects or other reproductive harm.

!

WARNING:

!

 

 

 

This product contains or emits chemicals

 

 

known to the state of California to cause

 

cancer, birth defects or other reproductive harm.

Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this manual and with the unit. The generator can operate safely, efficiently and reli- ably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.

Generac cannot possibly anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit, are, therefore, not all-inclusive. If you use a procedure, work method or operating tech- nique Generac does not specifically recommend, you must satisfy yourself that it is safe for you and others. You also must make sure the procedure, work method or operating technique that you choose does not render the generator unsafe.

! GENERAL HAZARDS !

For safety reasons, Generac recommends that the installation, initial start-up and mainte- nance of this equipment is carried out by a Generac Authorized Service Dealer.

The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentra- tions, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISON- ING ARE (a) inability to think coherently, (b) nau- sea, (c) vomiting, (d) twitching muscles, (e) throb- bing temples, (f) dizziness, (g) headaches, (h) weakness, and (i) sleepiness. IF YOU EXPERI-

ENCE ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PER- SIST, GET MEDICAL HELP. Shut down the gener- ator and do not operate it until it has been inspect- ed and repaired.

Never sleep in the vehicle while the genset is run- ning unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area.

DANGER

Despite the safe design of this generator,

!operating this equipment imprudently, neglect- ing its maintenance or being careless can cause possible injury or death. Permit only responsi- ble and capable persons to operate or maintain this equipment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot

!during operation. Exercise care near running generators.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and venti- lating air is critical to correct generator operation and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or per- mit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator.

When working on this equipment, remain alert at all times. Never work on the equipment when you are physically or mentally fatigued.

Inspect the generator regularly, and contact your nearest Generac Authorized Service Dealer imme- diately for parts needing repair or replacement.

2 Generac® Power Systems, Inc.

Image 4
Contents This manual should remain with the unit Authorized Service Dealer Location IntroductionTable of Contents General Hazards Electrical Hazards Generator Identification Reference Number IdentificationInstallation SafetyGenerator Applicability Generator AC Connection System1.1 Fuel Consumption gph/lbs.ph SpecificationsFuel Requirements Gasoline Generator Control Panel Automatic Choke Optional Remote START/STOP PanelBefore Starting the Engine Stopping the Generator Starting the GeneratorLetting the Engine Stabilize High Temperature Switch LOW OIL Pressure SwitchProtection Systems Field BoostChecking the Engine OIL Level Overvoltage Protection6 25-HOUR CHECK-UP 5 25-HOUR BREAK-IN PeriodCleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Clean Spark Arrestor Checking the Engine Spark PlugCleaning the Generator Battery MaintenanceWeekly Every SIX MonthsOUT of Service Procedure RV Generator Service IntervalDrive Belt Exercising the GeneratorQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Purpose and Scope Installation Instructions Standards BookletsEquipment Description Generator Engine Operating SpeedDimensions Drawing No E1058-A Location and Support Generator LocationGenerator Compartments Suspended MountingCompartment Size Generator RestraintSound Insulating Materials Typical Compartment ConstructionCooling and Ventilating AIR AcousticsCompartment Floor Cutouts Generator AirflowTesting the Installation Gasoline Fuel SystemGenerator Fuel Supply Line LP GAS Fuel SystemParts not Included in Fuel System Primary Regulator Some Important ConsiderationsVapor Withdrawal Gaseous CarburetionExhaust System Fuel Supply LinesLeakage Tests Excess Flow ValveExhaust System Safety Electrical ConnectionsMufflers and Spark Arrestors Electrical Junction BOXWiring Isolating Different Power SourcesPower Supply Cord Generator AC ConnectionsBattery Installation Recommended BatteryBattery Cables Battery Cable Connections18 Transfer Switch Isolation Method Optional Accessories Post Installation TestsBefore Initial START-UP Initial StartTesting Under Load Installation ChecklistTroubleshooting Guide Problem Cause CorrectionQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.