Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 Generator Compartments

Page 25

Section 6 – Installation

QUIETPACT 55, 65, and 75 Recreational Vehicle Generators

6.1.3 SUSPENDED MOUNTING

If you are going to suspend the generator below the horizontal support tubing, the suspension method you use with the vehicle frame members must (a) be able to support the weight of the generator AND (b) provide sufficient restraint for the generator. One typ- ical suspended mounting system is shown in Figure

6.2.The location of a suspended mounting system must be carefully planned, keeping the following gen- eral rules in mind:

Protect the generator against road splash and debris. Baffles or splash guards may be required to protect certain areas of the generator. To make sure the gen- erator is adequately protected, road test the installa- tion through mud, water and slush.

Figure 6.2 – Typical Suspended Mounting System

QUIETPACT 55G

The installer must make certain that the selected location will permit adequate cooling and ventilat- ing airflow to be supplied.

6.2GENERATOR COMPARTMENTS

Whether the generator set is being installed inside a compartment specifically manufactured to house a gen- erator or inside a compartment that the installer con- structs, the compartment MUST meet certain specifi- cations as outlined in the following sections:

6.2.1 COMPARTMENT SIZE

Plan the compartment size carefully. Provide a mini- mum clearance of 1/2 inch (13 mm) on the front and top, 1 inch (25 mm) on the sides, and 1/2 inch (13

mm)from the back for air circulation AFTER the compartment has been lined with metal and sound insulation (Figure 6.4).

NOTE:

Refer to “Figure 5.2 – Major Features and Dimensions” on Page 21.

Figure 6.4 – Clearances

Plywood

Compartment

1/2" Clearance on Top

1" Clearance

in Back

1" Each Side

Insulation

1/2"

in Front

 

6.1.4 GENERATOR RESTRAINT

Use four 3/8"-16 hardened steel bolts (Grade 5) to fas- ten the generator to the supporting frame or the sup- port tubing. These bolts must pass through (a) the gen- erator mounting base, (b) the compartment floor (if a compartment is used) and (c) the supporting frame- work (Figure 6.3). All bolts must be long enough so that when tight, at least three threads are visible past the retaining lock nuts. Refer to Section 6.2 for the location of the generator mounting holes.

Figure 6.3 – Typical Generator Restraint

6.2.2 COMPARTMENT CONSTRUCTION

The generator compartment should be either con- structed of, or lined with, 26-gauge galvanized steel.

NOTE:

Aluminum is NOT an acceptable alternative to galvanized steel due to aluminum’s low melting point.

If the compartment is lined with galvanized steel, it may be constructed of any material. Generac rec- ommends that the compartment be constructed of 1/2-inch thick plywood (not strandboard), with the floor made of a double thickness of 1/2-inch ply- wood with the grain of the wood at cross section for added strength (Figure 6.5).

Generac® Power Systems, Inc. 23

Image 25
Contents This manual should remain with the unit Introduction Authorized Service Dealer LocationTable of Contents General Hazards Electrical Hazards Reference Number Identification Generator IdentificationSafety InstallationGenerator Applicability Generator AC Connection System1.1 Fuel Consumption gph/lbs.ph SpecificationsFuel Requirements Gasoline Generator Control Panel Automatic Choke Optional Remote START/STOP PanelBefore Starting the Engine Stopping the Generator Starting the GeneratorLetting the Engine Stabilize LOW OIL Pressure Switch High Temperature SwitchProtection Systems Field BoostOvervoltage Protection Checking the Engine OIL Level6 25-HOUR CHECK-UP 5 25-HOUR BREAK-IN PeriodCleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Checking the Engine Spark Plug Clean Spark ArrestorBattery Maintenance Cleaning the GeneratorWeekly Every SIX MonthsRV Generator Service Interval OUT of Service ProcedureDrive Belt Exercising the GeneratorQuietpact 55, 65, and 75 Recreational Vehicle Generators Part General Hazards Electrical Hazards Standards Booklets Purpose and Scope Installation InstructionsEquipment Description Generator Engine Operating SpeedDimensions Drawing No E1058-A Generator Location Location and SupportSuspended Mounting Generator CompartmentsCompartment Size Generator RestraintTypical Compartment Construction Sound Insulating MaterialsAcoustics Cooling and Ventilating AIRCompartment Floor Cutouts Generator AirflowGasoline Fuel System Testing the InstallationGenerator Fuel Supply Line LP GAS Fuel SystemParts not Included in Fuel System Some Important Considerations Primary RegulatorVapor Withdrawal Gaseous CarburetionFuel Supply Lines Exhaust SystemLeakage Tests Excess Flow ValveElectrical Connections Exhaust System SafetyMufflers and Spark Arrestors Electrical Junction BOXIsolating Different Power Sources WiringPower Supply Cord Generator AC ConnectionsRecommended Battery Battery InstallationBattery Cables Battery Cable Connections18 Transfer Switch Isolation Method Post Installation Tests Optional AccessoriesBefore Initial START-UP Initial StartInstallation Checklist Testing Under LoadProblem Cause Correction Troubleshooting GuideQuietpact 55, 65, and 75 Recreational Vehicle Generators Battery Supplied by Customer 12V Battery 19 18 Part NO. QTY Description View a QTY Description 105 Screw Hhtt M6-1.0 X 10 YC 28,2 Circuit Breaker 3 X 15A 15B ASSEMBLY, Crankcase RV Exploded Views and Parts Lists CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 specifications

Generac has established itself as a leader in the power generation industry, particularly noted for its wide range of generators designed to provide reliable backup power. Among its various models, the Generac series consisting of the 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 stands out due to their dependable performance and innovative features. Each model in this series is engineered for both residential and light commercial applications, offering peace of mind during power outages.

One of the main features of these models is their state-of-the-art engine technology. Equipped with a Generac engine, these generators are designed to provide efficient, powerful performance. The engines are robust and designed to withstand extended use, ensuring that users can rely on them when needed most.

A standout feature is their Automatic Transfer Switch (ATS) capability. When the power goes out, these generators automatically switch on, providing uninterrupted power to essential appliances and systems in the home. This seamless transition is vital for maintaining safety and comfort during outages, eliminating the need for manual intervention.

Fuel efficiency is another area where these models excel. They utilize either natural gas or propane, offering flexibility in fuel choice depending on availability and preference. Their engineering is optimized for minimal fuel consumption while maximizing output, making them a cost-effective solution for power needs.

Furthermore, these models incorporate advanced monitoring and control systems. Users can conveniently monitor generator performance and status through an intuitive mobile app or control panel. This technology allows users to receive alerts and updates, ensuring they are always informed about the power situation at their location.

Noise reduction technology is also a key characteristic of this series. Generac's engineers have focused on minimizing sound output, providing a quieter operation compared to many other generators in the market. This feature is particularly beneficial for residential areas where noise can be a significant concern.

Overall, the Generac 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, and 004707-0 models exemplify reliability, efficiency, and advanced engineering. Their comprehensive features and user-friendly technology make them an excellent choice for anyone seeking a dependable backup power solution.